NovaFix-I Anterior Cervical Plate

NovaFix-I Anterior Cervical Plate provides secure cervical spine fixation for ACDF, trauma, and fusion procedures. OEM manufacturer and orthopedic implant supplier for global distributors.
  • 2100-89

  • CZMEDITECH

  • Titanium

  • 1 piece

  • CE/ISO:9001/ISO13485

  • FedEx / DHL / TNT / EMS / etc

  • OEM and ODM available

  • Technical support, product training, surgical guidance, and long-term after-sales service

  • Anterior cervical fixation for ACDF, corpectomy, trauma, degenerative instability, and tumor reconstruction. Levels C2–C7, single or multi‑level (up to 4 levels).

  • 90° limit‑locking mechanism – audible stop, prevents screw back‑out
    Curved & chamfered plate – anatomical lordosis, minimizes soft tissue irritation
    4 screw options – universal / directional + self‑tapping / self‑drilling
    Bidirectional spreader – expandable, pressurizable, multi‑joint for less field occlusion
    Plate bending pliers – uniform force, no plate damage
    Guide drill system – directional & universal guides for simpler workflow

Availability:

Product Description

Product Overview

NovaFix‑I is designed for anterior cervical discectomy and fusion (ACDF), corpectomy, trauma, and degenerative pathologies. It combines a 90° limit‑locking mechanism, an anatomically curved plate body, and four screw types to reduce soft tissue irritation, enhance construct stability, and improve intraoperative efficiency.

Clinical Application

  • ACDF (single or multi‑level)

  • Cervical corpectomy and reconstruction

  • Traumatic fractures / instability

  • Degenerative disc disease with instability

  • Tumor resection requiring anterior fixation

  • Revision surgeries

Target levels: C2 – C7 (up to 4 levels)
Compatible with: autograft, allograft, PEEK cage

Key Features

Plate Design

  • 90° limit‑locking – visual and audible confirmation of full locking, eliminates screw back‑out

  • Chamfered edges – reduces soft tissue irritation and risk of postoperative dysphagia

  • Overall curved surface – matches physiological cervical lordosis for better load distribution

Screw Options (4 in 1)

  • Universal self‑tapping / self‑drilling

  • Directional self‑tapping / self‑drilling

All screws available in 3.5 mm and 4.0 mm diameters. Self‑drilling tip preserves bone stock and reduces operative steps.

Smart Instrumentation

Plate Bending Pliers – even force distribution, no notches or surface damage during contouring.

Bidirectional Spreader

  • Expandable and pressurizable

  • Two‑way adjustable trigger for fine distraction / compression

  • Multi‑joint design → reduces visual field occlusion

Guide Drill System – dedicated directional & universal guides, color‑coded for intuitive use.

Complete Instrument Set – includes screw drivers, taps, depth gauge, torque limiter, and sterilization tray.

Comparison – NovaFix‑I vs. Conventional Anterior Cervical Plate

NovaFix-I Anterior Cervical Plate-CZMEDITECH.jpg

Feature

NovaFix‑I (New)

Conventional Plate (Old)

Locking mechanism

90° limit‑locking with audible stop

Basic snap‑on / friction lock

Plate geometry

Curved + chamfered → anatomical, low irritation

Flat or minimal contour, sharp edges

Screw versatility

4 types (universal/directional + self‑tapping/self‑drilling)

Usually 1–2 types, mostly fixed‑angle

Bidirectional spreader

Expandable, pressurizable, 2‑way trigger, multi‑joint

Basic ratchet spreader, bulkier

Plate bending pliers

Uniform force, no plate damage

May create stress risers

Guide drill system

Directional + universal guides, simple

Single guide, less intuitive

Self‑drilling option

Yes – reduces drilling steps

Always requires pre‑drilling

Biomechanical advantage

Better load distribution

Flat design may cause stress concentration

Clinical insight: NovaFix‑I’s 90° limit‑locking and chamfered profile significantly reduce screw back‑out and soft tissue irritation, while the four screw options and advanced instruments offer unmatched surgical flexibility.

Why Choose NovaFix‑I?

  • Safety – positive locking feedback eliminates back‑out risk

  • Less dysphagia – low‑profile, curved and chamfered design

  • Efficiency – self‑drilling screws + intuitive guides shorten OR time

  • Versatility – four screw types adapt to any bone quality

  • Superior instrumentation – bidirectional spreader and bending pliers improve visibility and handling

Frequently Asked Questions (FAQ)

1. What is the main advantage of the 90° limit‑locking design?

The 90° limit‑locking provides an audible click and visual confirmation when the screw is fully locked. This prevents screw back‑out, a common complication with traditional snap‑on or friction‑lock mechanisms, and enhances construct stability without additional steps.

2. Which cervical levels are compatible with NovaFix‑I?

NovaFix‑I is indicated for C2 through C7. It supports single‑level as well as multi‑level constructs up to four vertebral levels.

3. Do I need to pre‑drill for all screws?

No. The system includes self‑drilling screws (both universal and directional variants). For patients with good bone quality, self‑drilling screws eliminate the pre‑drilling step, reducing operative time and preserving bone stock. Traditional self‑tapping screws are also available for denser bone.

4. How does the bidirectional spreader differ from standard spreaders?

The bidirectional spreader can both distract and compress (expandable and pressurizable). It features a two‑way adjustable trigger for finer control, and its multi‑joint design reduces obstruction of the surgical field, offering better visibility during anterior cervical approaches.

5. Can I bend the plate to match patient anatomy? Does bending damage the plate?

Yes, the plate can be gently contoured using the dedicated Plate Bending Pliers. These pliers distribute force evenly, preventing notches, surface scratches, or structural damage that often occurs with generic bending tools.

6. What screw sizes and types are available?

All screws come in 3.5 mm and 4.0 mm diameters. Four configurations are offered:

  • Universal self‑tapping

  • Universal self‑drilling

  • Directional self‑tapping

  • Directional self‑drilling

Color‑coded instruments help identify each type quickly.

7. Is the instrument set complete for a standard ACDF procedure?

Yes. The instrument set includes plate bending pliers, bidirectional spreader, guide drill system (directional + universal guides), screw drivers, taps, depth gauge, torque limiter, and a sterile organizing tray. No additional essential instruments are needed.

8. What is the plate material and thickness?

The NovaFix‑I plate is manufactured from Ti‑6Al‑4V titanium alloy (ISO 13485 certified). It has a low‑profile, curved design that minimizes prominence while maintaining biomechanical strength.

9. Are the implants MRI safe?

Yes. Titanium alloy implants are MR conditional. Please refer to the surgical technique guide for specific MRI safety information.

10. Where can I get a surgical technique manual or pricing information?

Contact CZMEDITECH directly via your regional distributor or the official website. Full surgical technique guides, catalogues, and quotation requests are available upon request.

Technical Specifications

  • Material: Titanium alloy (Ti‑6Al‑4V)

  • Plate sizes: Length 21–70 mm, Width 14–18 mm

  • Screw diameters: 3.5 mm / 4.0 mm

  • Sterility: Implants supplied sterile; instruments reusable

  • Standards: ISO 13485 certified

Contact & Ordering

For full surgical technique guide, catalog, or pricing, please contact CZMEDITECH directly.

Caution: For professional orthopedic and neurosurgeon use only.

NovaFix‑I – Precision. Safety. Anatomical Harmony.

Previous: 
Next: 

CZMEDITECH Helps You

Find our full ranges of solutions for different fractures.
 
* Cover all major spine categroies ;
* Always reassure customers in terms of quality and delivery time ;
* We pursue high cost performance,so that dealers have profit space.
Contact us

Consult Your CZMEDITECH Orthopedic Experts

We help you avoid the pitfalls to delivery the quality and value your orthopedic need, on-time and on-budget.
Changzhou Meditech Technology Co., Ltd.

Products

Service

Inquiry Now
© COPYRIGHT 2023 CHANGZHOU MEDITECH TECHNOLOGY CO., LTD. ALL RIGHTS RESERVED.