Zawhna i nei em?        +86- 18112515727 ah      zawhfiah theih a ni  hla@orthopaedic-china.com ah hian a awm a
Please Choose Your Language
Hetah hian i awm a ni: In » Thil siam chhuah te » Spine a ni » Spinal Implant te pawh a awm » NovaFix-I Anterior Cervical Plate

loading a ni

Share to:
facebook ah in share theih a ni
twitter hmanga share theih a ni
line insem theihna button a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
whatsapp share theihna tur a ni
sharethih hi share theih a ni

NovaFix-I Hma lam Cervical Plate-ah hian a awm a

NovaFix-I Anterior Cervical Plate hian ACDF, trauma, leh fusion procedure hrang hrang atan cervical spine fixation him tak a pe a ni. Khawvel pum huapa distributor te tan OEM siamtu leh orthopedic implant supplier a ni.
  • 2100-89 thleng a ni

  • CZMEDITECH a ni

  • 1 piece a ni

  • Titanium a ni

  • OEM leh ODM a awm bawk

  • CE/ISO:9001/ISO13485 a ni

  • Technical support, product training, surgical guidance, leh hun rei tak chhunga hralh hnua service pek te a ni

  • FedEx / DHL / TNT / EMS / etc. te hi a ni

  • ACDF, corpectomy, trauma, degenerative instability, leh tumor siam tharna atana hmalam cervical fixation te hi a ni. Level C2–C7, single emaw multi‐level emaw (level 4 thleng) a ni.

A awm theih dan:

Product Description chungchang

Product chungchang tlangpui

NovaFix‐I hi anterior cervical discectomy leh fusion (ACDF), corpectomy, trauma, leh degenerative pathologies te tan ruahman a ni. 90° limit‐locking mechanism, anatomically curved plate body, leh screw type pali te a hmang khawm a, soft tissue irritation tihziaawmna tur, construct stability tihchangtlunna tur leh intraoperative efficiency tihsan nan a hmang a ni.

Clinical-a hman dan tur

  • ACDF (single emaw multi‐level emaw) 1.1.

  • Cervical corpectomy leh siam thar lehna

  • Traumatic fractures / dinhmun nghet lo (instability) a awm

  • Degenerative disc natna leh instability nei lo

  • Tumor resection atan hmalam fixation a ngai

  • Revision surgery neih a ni

Target level: C2 – C7 (level 4 thleng)
A inmil: autograft, allograft, PEEK cage

Thil pawimawh tak tak

Plate Design siam a ni

  • 90° limit‐locking – hmuh theih leh hriat theiha full locking tih nemnghehna, screw back‐out a titawp

  • Chamfered edges – soft tissue irritation leh postoperative dysphagia awm theihna a ti tlem

  • Overall curved surface – load distribution tha zawk neih nan physiological cervical lordosis nen a inmil

Screw duhthlan tur (1 in 4) .

  • Universal self‐tapping / mahni inrintawkna (self‐drilling) a ni

  • Directional self‐tapping / mahni inhriatthiamna (self‐drilling) tih

Screw zawng zawng hi 3.5 mm leh 4.0 mm diameter-a awm vek a ni. Self‐drilling tip hian ruh stock a humhim a, operative step pawh a ti tlem bawk.

Smart Instrumentation hmanga siam a ni

Plate Bending Pliers – force distribution pawh nise, contouring neih laiin notch emaw surface damage emaw a awm lo.

Bidirectional hmanga thehdarhtu – 1.1.

  • Expand theih leh pressure siam theih a ni

  • Two‐way adjustable trigger hmangin distraction / compression tha tak a awm thei

  • Multi‐joint design → hian mit hmuhna hmun (visual field occlusion) a ti tlem

Guide Drill System – directional & universal guide bik, hman awlsam zawka hman theih turin color‐coded a ni.

Instrument Set kimchang – screw driver, tap, depth gauge, torque limiter, leh sterilization tray te a awm a.

Inthlauhna – NovaFix‐I leh Conventional Anterior Cervical Plate te nen khaikhin a ni

NovaFix-I hmalam panna kawngkhar-CZMEDITECH.jpg

Nihphung

NovaFix‐I (Thil thar) 1.1.

Plate pangngai (Hmanlai) .

Locking mechanism a ni

90° limit‐locking a ni a, audible stop a awm bawk

Basic snap‐on / friction lock hman theih a ni

Plate geometry a ni

Curved + chamfered → taksa peng hrang hranga awm, irritation tlem

Flat emaw minimal emaw contour, a sir hrual

Screw hmanga hman theih a ni

chi 4 (universal/directional + mahni in tapping/mahni in drilling) a awm.

A tlangpuiin chi 1–2, a tam zawk chu fixed‐angle a ni

Bidirectional hmanga thehdarh thei

A zau zawnga tihzauh theih, pressure siam theih, 2‐way trigger, multi‐joint

Basic ratchet spreader, a lian zawk

Plate bending pliers hmanga siam a ni

Uniform force, plate tihchhiat a awm lo

Stress riser a siam thei

Guide drill system hmanga siam a ni

Directional + universal kaihhruaina, awlsam tak

Single guide, hriatthiam awlsam lo zawk

Self‐drilling tih theih a ni

Ni e – drilling step a tihtlem

Pre‐drilling a ngai fo thin

Biomechanical lama hlawkna a awm

Load distribution tha zawk

Flat design hian stress concentration a thlen thei

Clinical insight: NovaFix‐I-a 90° limit‐locking leh chamfered profile hian screw back‐out leh soft tissue irritation nasa takin a tihtlem a, screw option pali leh instrument hmasawn tak takte hian surgical flexibility tluk loh a pe thung.

Engvangin Nge NovaFix‐I hi kan thlan?

  • Safety – positive locking feedback hian back‐out risk a ti bo thin

  • Dysphagia tlem zawk – low‐profile, curved leh chamfered design a ni

  • Efficiency – self‐drilling screw + intuitive guide te hian OR hun a ti tawi

  • Versatility – screw chi pali hi ruh quality eng pawha inmil thei

  • Instrumentation tha zawk – bidirectional spreader leh bending pliers te hian hmuh theihna leh handling a ti tha zawk

Zawhna zawh fo thin (FAQ) .

1. 90° limit‐locking design hian eng nge a thatna ber?

90° limit‐locking hian screw chu a lock kim chuan audible click leh visual confirmation a pe a ni. Hei hian screw back‐out, traditional snap‐on emaw friction‐lock mechanism-a harsatna awm fo chu a veng a, step dang pawh tih belh ngai lovin construct stability a ti sang bawk.

2. NovaFix‐I nen hian eng cervical level nge inmil?

NovaFix‐I hi C2 atanga C7 thleng tan a ni. Single‐level bakah multi‐level construct te pawh vertebral level pali thleng a support thei bawk.

3. Screw zawng zawng pre‐drill ka mamawh em?

No. System ah hian self‐drilling screw (universal leh directional variant pahnih) a awm a. Ruh quality tha nei damlo tan chuan self‐drilling screw hian pre‐drilling step a ti bo a, operation hun a ti tlem a, ruh stock a humhim bawk. Traditional self‐tapping screw pawh ruh denser zawk atan a awm bawk.

4. Engtin nge bidirectional spreader hi standard spreader nen a danglam?

Bidirectional spreader hian distract leh compress (expandable leh pressurizable) a ti thei bawk. Control finer zawk nan two‐way adjustable trigger a nei a, a multi‐joint design hian surgical field-a obstruction a tihziaawm a, anterior cervical approach-ah hmuh theihna tha zawk a pe bawk.

5. Damlo taksa peng hrang hrang nena inmil turin plate chu ka ben thei ang em? Bending hian plate a tichhia em?

Ni e, plate chu dedicated Plate Bending Pliers hmangin zawi zawiin contoured theih a ni . Heng pliers te hian force chu inang tlangin an sem darh a, notch, surface scratches, emaw structural damage generic bending tools hmanga thleng fo thin te chu a veng thei a ni.

6. Eng screw size leh type nge awm?

Screw zawng zawng hi 3.5 mm leh 4.0 mm diameter a awm vek a ni. Configuration pali a awm a:

  • Universal self‐tapping tih hi a ni

  • Universal self‐drilling tih a ni

  • Directional self‐tapping tih a ni

  • Directional self‐drilling tih a ni

Color‐coded instruments hian chi hrang hrangte chu rang taka hriat theihna turin a pui a ni.

7. Standard ACDF procedure atan instrument set chu a kim tawh em?

Awle. Instrument set-ah hian plate bending pliers, bidirectional spreader, guide drill system (directional + universal guides), screw driver, tap, depth gauge, torque limiter, leh sterile organizing tray te a awm a ni. Instrument pawimawh dang a ngai lo.

8. Plate material leh a thickness chu engzat nge ni?

NovaFix‐I plate hi Ti‐6Al‐4V titanium alloy (ISO 13485 certified) atanga siam a ni. Low‐profile, curved design a nei a, biomechanical strength vawng reng chungin prominence a ti tlem hle.

9. Implants MRI hmanga siam hi a him em?

Awle. Titanium alloy implant hi MR conditional a ni. MRI himna chungchang chiang tak hriat duh chuan surgical technique guide hi en la.

10. Khawi atanga surgical technique manual emaw, pricing information emaw ka hmuh theih ang?

zawhfiah theih a ni . CZMEDITECH hi i regional distributor emaw official website emaw kaltlangin direct-in Surgical technique guide kimchang, catalogue, leh quotation dilna te chu dil theih a ni.

Technical lam thil chi hrang hrang

  • Thil hman tur: Titanium alloy (Ti‐6Al‐4V) hmanga siam a ni.

  • Plate lian leh te: A sei zawng 21–70 mm, A zau zawng 14–18 mm

  • Screw sei zawng: 3.5 mm / 4.0 mm a ni

  • Sterility: Implant supply te chu sterile a ni a; instruments hman nawn theih a ni

  • Standards: ISO 13485 certified a ni

Contact & Order tih theih a ni

A kimchangin surgical technique kaihhruaina, catalog , emaw pricing emaw, zawhfiah theih a ni CZMEDITECH direct a ni.

Fimkhur tur: Professional orthopaedic leh neurosurgeon hman tur chauh.

NovaFix‐I – A dikna. Sahimna. Anatomical Harmony a ni.

Hma chiah: 
Dawtchiah: 

CZMEDITECnal Implant Supplier tha ber ber: Kum 2026 chhunga Company hriat tur tha ber ber 15

Fracture hrang hrang tan kan solution zawng zawng zawng rawh.
 
* Spine categroies lian zawng zawng khuh vek tur ;
* Quality leh delivery time lamah customer te thlamuan fo thin ;
* High cost performance kan zawm a,dealer ten profit space an neih theih nan.
Min rawn biak theih reng e