1029022008
CZMEDITECH
Titanium
1 piece
CE/ISO:9001/ISO13485
FedEx / DHL / TNT / EMS / etc
OEM and ODM services are available, including customized sizes, packaging, and branding.
Technical support, product training, surgical guidance, and long-term after-sales service
TLIF, PLIF, OLIF, degenerative disc disease, spinal stenosis, spondylolisthesis, lumbar instability.
Porous titanium structure
• Enhanced bone ingrowth
• Large graft chamber
• High-strength titanium alloy
• Optimized load distribution
• Restores disc height
• MIS compatible
| Availability: | |
|---|---|
Product Description
The LIFUS Titanium Cage from CZMEDITECH is an advanced spinal fusion implant engineered to support lumbar interbody fusion procedures while promoting long-term biological fixation and spinal stability. Manufactured from medical-grade titanium alloy and featuring a porous surface structure, the cage is designed to enhance osseointegration, maximize endplate contact, and facilitate successful fusion outcomes.
As spinal surgeons increasingly seek implants that combine biomechanical strength with biological performance, titanium cages have become a preferred alternative to traditional interbody fusion devices. The CZMEDITECH LIFUS Titanium Cage is suitable for both open and minimally invasive spinal procedures and is designed to address a wide range of degenerative, traumatic, and deformity-related spinal conditions.
Compared with traditional interbody implants, porous titanium cages offer several clinical advantages:
Enhanced bone ingrowth and osseointegration
Improved implant stability
Better load sharing characteristics
Reduced risk of implant migration
Long-term structural support
Optimized fusion environment
Excellent biocompatibility
The LIFUS Titanium Cage integrates these advantages into a single implant system, helping surgeons achieve predictable spinal fusion outcomes.
The LIFUS Titanium Cage is indicated for:
Degenerative Disc Disease (DDD)
Lumbar Disc Herniation
Lumbar Spinal Stenosis
Spondylolisthesis
Degenerative Scoliosis
Lumbar Instability
Recurrent Disc Disease
Revision Spine Surgery
Trauma-Related Lumbar Reconstruction
Interbody Fusion Procedures
TLIF (Transforaminal Lumbar Interbody Fusion)
PLIF (Posterior Lumbar Interbody Fusion)
OLIF (Oblique Lumbar Interbody Fusion)
MIS-TLIF (Minimally Invasive TLIF)
The porous titanium structure is engineered to support bone ongrowth and biological fixation, creating an optimal environment for spinal fusion.
The implant provides a spacious graft chamber that allows sufficient packing of autograft, allograft, or synthetic bone substitutes.
The cage geometry maximizes contact with vertebral endplates, helping distribute physiological loads and reduce stress concentration.
Manufactured from medical-grade Ti6Al4V titanium alloy, delivering excellent fatigue resistance and long-term durability.
Designed to accommodate lumbar anatomy and facilitate implantation during lumbar fusion procedures.
Provides immediate mechanical support to maintain disc height and spinal alignment after implantation.
The implant design allows surgeons to evaluate fusion progression during postoperative follow-up.
Compatible with modern MIS techniques, helping reduce tissue disruption while maintaining procedural effectiveness.
Parameter | Specification |
|---|---|
Product Name | LIFUS Titanium Cage |
Material | Ti6Al4V Titanium Alloy |
Surface Technology | Porous Titanium Surface |
Surgical Indications | Lumbar Fusion |
Bone Graft Area | Large Central Graft Chamber |
Sterilization | Non-Sterile |
Packaging | Individually Packed |
Surgical Approach | TLIF / PLIF / OLIF |
Compatibility | Standard Lumbar Fusion Instrumentation |
Intended User | Spine Surgeons |
The porous titanium structure encourages bone integration and long-term fusion stability.
Helps maintain intervertebral height and foraminal dimensions following disc removal.
Contributes to restoration of lumbar alignment and physiological load transmission.
Optimized contact surfaces assist in distributing loads across vertebral endplates.
Designed for intuitive implantation and compatibility with standard lumbar fusion instruments.
CZMEDITECH offers a complete range of spinal implant solutions:
Pedicle Screw Systems
MIS Pedicle Screw Systems
Cervical Plate Systems
Cervical Cages
PEEK Cages
Titanium Cages
Expandable Cages
Interspinous Devices
We provide:
Private Label Manufacturing
Custom Packaging
Distributor Branding
Product Customization
Market-Specific Solutions
CZMEDITECH supports distributors, hospitals, and spine centers across:
Latin America
Southeast Asia
Middle East
Africa
Europe
Our manufacturing processes follow internationally recognized quality management systems to ensure product consistency and reliability.
A LIFUS Titanium Cage is an interbody fusion implant used during lumbar fusion surgery to restore disc height, stabilize the spine, and support bone fusion.
Porous titanium cages promote bone ingrowth, improve biological fixation, enhance implant stability, and support long-term fusion outcomes.
The implant can be used in TLIF, PLIF, OLIF, and selected minimally invasive lumbar fusion procedures.
The cage is manufactured from medical-grade Ti6Al4V titanium alloy.
Yes. The large central chamber is designed to accommodate various bone graft materials.
Yes. The implant is compatible with MIS spinal fusion techniques.
Titanium cages provide excellent mechanical strength and biological integration, while PEEK cages offer radiolucency. The choice depends on surgeon preference and clinical requirements.
Yes. CZMEDITECH offers OEM and ODM solutions for qualified distributors worldwide.
Degenerative disc disease, lumbar stenosis, spondylolisthesis, disc herniation, spinal instability, and revision spinal fusion procedures.
The product is intended for qualified spine surgeons and healthcare professionals trained in spinal fusion procedures.