Proximal lateral tibial locking plate-i .

  • 5100-25 a ni.

  • CZMedItech 1000 a ni.

A awm theihna:

Product sawifiahna .

Proximal lateral tibial locking plate chu eng nge ni?

CZMedItech LCP® proximal tibia plate hi LCP periarticular plating system-a tel a ni a, locking screw technology leh plating technique pangngai te chu a inzawm khawm a ni. LCP periarticular plating system hian distal femur complex fractures te chu LCP condylar plate te nen, proximal femur complex fractures te nen LCP proximal femur plates leh LCP te nen a hmachhawn thei a ni.

Proximal femur hook plate te, leh LCP proximal tibia plate leh LCP medial proximal tibia plate te hman laiin proximal tibia a fracture complex tak tak te a awm bawk.

Locking compression plate (LCP) hian plate shaft-ah combi hole a nei a, chu chuan dynamic compression unit (DCU) hole leh locking screw hole a inzawm khawm a ni. Combi hole hian plate shaft sei zawng zawngah axial compression leh locking theihna a pe thei a ni.

Plate features:

  • Anatomically contoured a nih chuan proximal tibia lateral aspect chu a approximate thei ang.

  • Load-sharing construct siam turin tension siam theih a ni .

  • Left leh right configuration-ah te a awm a, 316L stainless steel emaw, sumdawnna atana pure (CP) titanium-ah emaw a awm bawk.

  • Plate shaft ah 5、7、9 emaw 11 combi holes nen a awm thei

  • Head thlenga round hole pahnih distal te hian 3.5 mm cortex screw leh 4.5 mm cancellous bone screw te chu interfragmentary compression atan emaw, plate position nghet taka dah theih nan emaw an pawm a ni.

  • Angled, threaded hole, round hole pahnih atanga hla taka awm chuan 3.5 mm cannulated locking screw chu a pawm a ni. Hole angle hian he locking screw hi plate head-a central locking screw nen a inzawm theih nan medial fragment a support thei a ni.

  • Combi holes, angled locking hole-a distal, DCU hole leh threaded locking hole nena inzawm khawm

  • Limited-contact-a thu zawhfiah theih a ni.


Proximal lateral tibial locking plate-i .

Specifications 1.1.

thil siam chhuah te . Ref a ni a. Specification 100 a ni. Thickness . Vang Dung

Proximal lateral tibial locking plate-i . 

(3.5/5.0 locking screw/ 4.5 cortical screw hmang rawh)

5100-2501 a ni. 3 holes l . 4.6 14 117
5100-2502 a ni. 5 holes l . 4.6 14 155
5100-2503 a ni. 7 holes l . 4.6 14 193
5100-2504 a ni. 9 holes l . 4.6 14 231
5100-2505 a ni. 11 holes l . 4.6 14 269
5100-2506 a ni. 3 holes r . 4.6 14 117
5100-2507 a ni. 5 holes r . 4.6 14 155
5100-2508 a ni. 7 holes r . 4.6 14 193
5100-2509 a ni. 9 holes r . 4.6 14 231
5100-2510 a ni. 11 holes r . 4.6 14 269


Thlalak tak tak .

Proximal lateral tibial locking plate a awm bawk.

Blog 100 a ni.

Proximal Lateral Tibial Locking Plate: Indication, surgical technique, leh outcome te thlirletna

Proximal tibia a fracture te hi enkawl a harsa thei hle a, a bik takin comminuted emaw osteoporotic fractures a awm chuan. Proximal lateral tibial locking plate (PLTLP) hman hi heng complex fractures enkawlna atana hmanraw tangkai tak a ni chho ta a ni. He thuziak ah hian PLTLP hmanna nena inzawm indication te, surgical technique te, leh outcomes te kan sawi dawn a ni.

Indication te .

PLTLP hi a bul berah chuan proximal tibia ruh tliak enkawlna atan hman a ni a, chutah chuan tibial plateau, medial leh lateral condyles te, leh proximal shaft te pawh a tel a ni. A bik takin fractures, traditional methods nena stabilize harsa tak tak, intramedullary nails emaw external fixators emaw te tan a tangkai hle. PLTLP hi nonunion emaw malunion emaw a nih chuan proximal tibia a nih chuan hman theih a ni bawk.

Surgical technique hman dan .

PLTLP hi a tlangpuiin knee joint-a lateral approach hmanga dah a ni. Surgeon chuan khup lateral aspect-ah incision a siam ang a, chutah chuan fracture site chu a pholang ang. Chumi hnuah chuan fracture fragment te chu tihtlem a ni a, Kirschner wire hmangin a hmunah hun eng emaw chen an dah a ni. A dawtah chuan PLTLP chu proximal tibia fit turin contoured a ni a, locking screw hmangin a hmunah fixed a ni. Locking screw te hian ruh nena inzawmna neiin stability a pe a, rotational emaw angular motion emaw a veng thei bawk.

Outcome 1000 a ni.

Zirna hrang hrangah PLTLP hman hian union rate sang tak leh clinical outcome tha tak a thlen tih hmuhchhuah a ni. Zirna pakhatah chuan union rate 98% a ni a, mean knee society score chu thla 24 chhunga a vaiin follow-up-ah a awm a ni. Zirchianna dang chuan union rate 97% leh mean knee society score 88 chu a vaiin thla 48 chhung a enkawl a ni. Mahse, hriat tur chu mimal outcome hi damlo bik leh fracture characteristics a zirin a danglam thei a ni.

harsatna awm thei te .

PLTLP hman avanga harsatna awm thei te chu infection, nonunion, malunion, leh hardware failure te a ni. Damlo thlan leh surgical technique uluk taka siam hi harsatna awm thei tur tihtlem nan a pawimawh hle. Surgeon chuan a chhehvela soft tissue, peroneal nerve emaw, lateral collateral ligament emaw tihchhiat loh nan a fimkhur tur a ni bawk.

Tawpna

Proximal lateral tibial locking plate hi proximal tibia complex fractures enkawlna atana hmanraw tangkai tak a ni. Stability a pe a, early mobilization a phalsak a, chu chuan clinical outcome tha zawk a thlen thei a ni. Complication a awm theih laiin, uluk taka damlo thlan leh surgical technique hmang hian a hlauhawmna a tlem thei hle. A pum puia thlir chuan PLTLP hi orthopedic surgeon Armamentarium-a proximal tibia fracture enkawlna atana thil hlu tak a ni.

FAQS 1000 a ni.

  1. Engtin nge proximal lateral tibial locking plate hi proximal tibia fractures enkawlna kawng dang nen a khaikhin? PLTLP hi proximal tibia-a complex fractures, a bik takin traditional methods nena stabilize harsa tak takte enkawlna atana hmanraw tangkai tak a nih thu hmuhchhuah a ni. Mahse, mimal outcome chu damlo bik leh ruh tliak (fracture characteristics) a zirin a danglam thei.

  2. Proximal lateral tibial locking plate hman hian eng nge a thatna? PLTLP hian fracture fragments te chu stable fixation a pe a, early mobilization a phalsak a, hei hian clinical outcome tha zawk a thlen thei a ni. A bik takin, traditional methods nena stabilize harsa tak, complex fractures tan chuan a tangkai hle.

  3. Proximal lateral tibial locking plate hman hian eng harsatna nge a thlen theih? PLTLP hman avanga harsatna awm thei te chu infection,nonunion, malunion, leh hardware failure te an ni. Damlo thlan leh surgical technique uluk taka siam hian harsatna awm thei tur a tihtlem theih phah a ni.

  4. Proximal lateral tibial locking plate a dam theih nan eng chen nge a rei ang? PLTLP a dam theih hun chhung hi damlo pakhat zel leh a ruh tliak awm dan azirin a danglam thei. Mahse, zirchiannaah chuan PLTLP hmanna nen union rate sang tak a awm tih hmuhchhuah a ni.

  5. Proximal lateral tibial locking plate chu a hliam tawh hnuah a la chhuak thei ang em? Ni e, PLTLP hi fracture a dam tawh chuan a tidam thei a, chu chuan hrehawmna emaw, thil dang emaw a thlen chuan. Mahse, hardware lakchhuah tura thutlukna siam chu case-by-case basis-a siam tur a ni a, damlo surgeon nen inrawnkhawmin siam tur a ni.



Hma chiah: 
Dawtchiah: 

I CZMedItech orthopedic mithiamte zawt rawh

I orthopedic mamawhna, a hun leh a budget-a i mamawh tur thilte delivery-na atana harsatna awmte chu pumpelh turin kan pui che a ni.
A rilru a hah lutuk chuan a rilru a buai em em a.

Thawhna

Inquiry tunah hian .
© Copyright 2023 Changzhou Meditech Technology Co., Ltd. Thuneihna zawng zawng a nei.