Have any questions?       +86-18112515727       song@orthopedic-china.com
Please Choose Your Language
You are here: Home » Products » Intramedullary Nail » Intramedullary Nails » DFN Intramedullary Nail Box 1000-0135

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

DFN Intramedullary Nail Box 1000-0135

  • 1000-0135

  • CZMEDITECH

  • Titanium

  • CE/ISO:9001/ISO13485

  • FedEx. DHL.TNT.EMS.etc

Availability:
Quantity:

Product Description


DFN Intramedullary Nail Box 1000-0135

307-3

DFN Distal Femurintramedullary Nail (Spiral Blade Screw Type) is an internal fixation implant designed for distal femoral fractures, featuring a blade-locking mechanism and retrograde insertion technique to enhance stability and anti-rotation, ideal for osteoporotic or complex fractures.

182-7

Main Storage Box        

Serving as the central unit, it features durable metal construction with a silver finish and a handle for convenient carrying. The interior is meticulously divided with compartments and securing fixtures to safely hold various-sized nails, preventing movement or damage during transit.

182-9

Stackable Sub-boxes (2 units)        

Engineered to fit snugly within the main box, these sub-boxes allow nested storage. Each unit is equipped with labeling systems for categorized sorting of different nail components. Their sidewalls incorporate grooves and protrusions to ensure stable stacking, maximizing space-saving potential.


1200


#f0f0f0


Product Advantage

276-1

Spiral Locking

Unique distal locking options The unique distal combination holes can used with standard locking screw or Spiral blade screw.

四宫格-2

Standard Locking

Unique distal locking options The unique distal combination holes can used with standard locking screw or Spiral blade screw.

四宫格-3

Diameter Length

Different diameters and lengths. Diameter from 9.5, 10, 11mm with length 160mm-400mm for different clinical needs.

四宫格-4

End Cap Types

Three different end cap meet the different requirements of the locking the spiral blade screw and standard locking screw.

#f0f0f0


#f0f0f0


Video


#f0f0f0


#f0f0f0

X-Ray


X-1

Case1

X-2

Case2


#f0f0f0


底




Features & Benefits


Expert R/Afn. Retrograde /Antegrade Femoral Nail(1)

Unique distal locking options

The unique distal combination holes can used with standard locking screw or Spiral blade screw.


Expert R/Afn. Retrograde /Antegrade Femoral Nail(2)

Unique distal locking options

The unique distal combination holes can used with standard locking screw or Spiral blade screw.


Expert R/Afn. Retrograde /Antegrade Femoral Nail

Different diameters and lengths

Diameter from 9.5,10.11mm with length 160mm-400mm for different clinical needs.


Expert R/Afn. Retrograde /Antegrade Femoral Nail

Different end cap

Three different end cap meet the different requirements of the locking the spiral blade screw and standard locking screw.



Specification

Brand
CZMEDITECH
Material
Titanium
Certificate
CE,ISO13485
Diameter
9.5/10/11/12mm
Length
160/180/200/220/240/260mm
Other
Customizable
Delivery Way
DHL/UPS/FEDEX/TNT/ARAMAX/EMS
Delivery Time
3-7 days

Actual Picture

0O7A9549

0O7A9538

0O7A9773_1

0O7A9790

Blog

Expert DFN Distal Femur Intramedullary Nail: Revolutionizing Orthopedic Surgery

Orthopedic surgery has witnessed significant advancements in recent years, particularly in fracture fixation techniques. One such innovative approach is the DFN Distal Femur Intramedullary Nail, a surgical procedure that has revolutionized the treatment of femoral shaft fractures.


Introduction to Expert DFN Distal Femur Intramedullary Nail

DFN Distal Femur Intramedullary Nail is a sophisticated surgical technique used to stabilize and heal fractures of the femoral shaft, providing patients with quicker recovery times and improved outcomes compared to traditional fixation methods.


Understanding Femoral Nailing Techniques

Retrograde Femoral Nailing

Retrograde femoral nailing involves inserting a nail into the femur from the knee joint, allowing for stable fixation and alignment of fractures.

Antegrade Femoral Nailing

Antegrade femoral nailing, on the other hand, involves inserting a nail from the hip joint, providing surgeons with versatile options for addressing different types of femoral fractures.


Indications for DFN Distal Femur Intramedullary Nail

DFN Distal Femur Intramedullary Nail is indicated for various conditions, including fractures of the femoral shaft and cases of non-union or malunion following previous femoral fractures.


Advantages of DFN Distal Femur Intramedullary Nail Over Traditional Fixation Methods

DFN Distal Femur Intramedullary Nail offers several advantages over traditional fixation methods, such as minimal soft tissue damage, reduced surgical time, and improved patient mobility post-surgery.


Surgical Procedure of DFN Distal Femur Intramedullary Nail

The surgical procedure of DFN Distal Femur Intramedullary Nail involves meticulous preoperative evaluation and planning, precise intraoperative steps, and comprehensive postoperative care and rehabilitation protocols.


Complications and Risk Factors Associated with DFN Distal Femur Intramedullary Nail

While DFN Distal Femur Intramedullary Nail is generally safe and effective, it is essential to be aware of potential complications and risk factors, including infection, implant failure, and nerve injury.


Case Studies and Success Stories of DFN Distal Femur Intramedullary Nail

Numerous case studies and success stories highlight the positive impact of DFN Distal Femur Intramedullary Nail on orthopedic surgery, showcasing improved patient outcomes and enhanced quality of life.


Future Trends and Innovations in DFN Distal Femur Intramedullary Nail Technology

The future of DFN Distal Femur Intramedullary Nail technology looks promising, with ongoing advancements focusing on enhanced implant designs, navigation systems, and biomechanical innovations.


Conclusion: The Impact of DFN Distal Femur Intramedullary Nail on Orthopedic Surgery

In conclusion, Expert DFN Distal Femur Intramedullary Nail has emerged as a game-changer in orthopedic surgery, offering surgeons and patients a reliable and effective solution for femoral shaft fractures.


Previous: 
Next: 

Consult Your CZMEDITECH Orthopedic Experts

We help you avoid the pitfalls to delivery the quality and value your orthopedic need, on-time and on-budget.
Changzhou Meditech Technology Co., Ltd.

Products

Service

Inquiry Now
© COPYRIGHT 2023 CHANGZHOU MEDITECH TECHNOLOGY CO., LTD. ALL RIGHTS RESERVED.