FNS (Femoral Neck System) hi orthopedic fixation system bik a ni a, ke ruh tliak te chu a nghet taka enkawlna atana siam a ni. Traditional cannulated screw-te tihkhawtlai theihna tura siam a ni a, he system hian angular stability tihchakna, controlled compression, leh hip fracture management atan fixation rintlak tak a pe a ni.
  • 3300-01 ah zawh theih a ni

  • CZMEDITECH a ni

  • Titanium Alloy hmanga siam a ni

  • 1 set a ni

  • CE, ISO 13485 a ni

  • FedEx, DHL, TNT, EMS, etc. te pawh a awm bawk.

  • OEM leh ODM a awm bawk

  • Quality guarantee, technical support, fast response, returns & maintenance te a awm bawk.

  • Femoral neck fracture a awm chuan internal fixation hman a ni

  • Anatomically contoured design a ni a, a fit tha ber tur a ni.
    Fixation nghet tak leh micromotion tihtlem a ni.
    Minimally invasive technique nena inmil.
    Soft tissue irritation tih tlem nan surface smooth.

A awm theih dan:

FNS (Femoral Neck System) tih hi a awm a.

FNS (Femoral Neck System) tih hi a awm a.

czmeditech-fns-femoral-neck-system-hip-fracture-fixation tih hi a ni

FNS Femoral Neck System atanga thil siam chhuah thlirletna

Femoral Neck Fracture te tan hian FNS Femoral Neck System hi eng nge ni?

FNS system hi medical device a ni a, femoral neck region-a fracture awmte chu hun eng emaw chen atana siam that, siamthat emaw stabilize emaw tura ruahman a ni. Anatomically contoured locking plate, central fixation bolt, anti-rotation screws, leh soft tissue tihbuai tlem ber nen precise placement support turin dedicated instrumentation te a awm a ni. CZMeditech Minimally invasive design hian incision tenau zawk, a chhehvel tissue-a trauma tihtlem, leh perioperative recovery period rei zawk, traditional open procedure nena khaikhin chuan a phalsak a ni.

FNS Hip Fixation System hman dan tur leh Clinical-a hman dan tur

Femoral Neck Fracture Fixation hman dan tur

  • Femoral neck fractures a awm chuan stable internal fixation a ngai a ni

  • Femoral head humhalh duhna hmuna fracture pattern

  • Damlo puitlingah chuan minimal invasive internal fixation hman a ngai a ni


Heng indication te hi product description-a tarlan hman tum nen a inmil a ni.

FNS Orthopaedic Implant hman loh tur

FNS system hi ruh quality tihchhiat nasa tak avanga internal fixation-in stabilization tha tak a pek theih lohna hmunah emaw, surgical site-a active infection-ah emaw hman loh tur a ni. Contraindication bikte chu: 

  • Fracture awm lo dinhmun

  • Active systemic emaw localized emaw infection a awm thei

  • Case-a bone stock tling lo, internal fixation atana tha lo

Damlo endikna dik leh surgical judgment hian device hman dan tur a kaihruai tur a ni.

Hip Fracture Internal Fixation atana vaukhânna leh fimkhur dan tur

Clinical decision-ah chuan damlo bikte ngaihtuah a ngai a, chung zingah chuan ruh quality, comorbidities, leh overall fracture complexity te pawh a tel. Surgeon-te chuan implant thlan leh dah dan chu an siam ṭhat a ngai a, chu chuan mechanical failure emaw postoperative complication emaw avanga hlauhawmna awm thei chu a ti tlem thei ang. Positioning leh alignment dik tak neih theih nan surgical imaging leh intraoperative monitoring te hi a tha hle.

Tin, he system hi hetiang hi a tamna hmunah hman loh tur a ni:


  • Sepsis natna (Sepsis) a awm

  • Malignant primary emaw metastatic tumor emaw a awm thei

  • Material sensitivity a ni

  • Vascularity tihchhiat a ni

Femoral Neck Internal Fixation System-a thil ha lo thleng thei

Internal fixation device leh surgical procedure dang ang bawkin risk a awm thei. Thil ha lo thleng thei tlangpui chu: 

  • Incision site ah natna hrik a awm

  • Implant loose emaw, a chhe emaw

  • Union emaw nonunion emaw tihkhawtlai

  • Soft tissue a ti na thei

  • Nerve emaw vessel emaw hliam hun eng emaw chen emaw, a awm reng emaw

  • Implant material atanga allergy awm thei

 I orthopaedic surgeon chuan operation hmain hlauhawmna awm thei leh harsatna awm thei tih tlem dan tur a sawiho ang.


DFN Distal Femur Intramedullary Nail (Spiral Blade Screw chi hrang hrang) hmanga siam a ni.

FNS Femoral Neck Fixation System-a thil pawimawh leh a hlawkna

fns-locking-plate-chuan-femoral-neck-fracture-fixation-czmeditech

FNS Femoral Neck Fixation System hman dan tur ruahmanna siam a ni

FNS Locking Plate a awm a

FNS (Femoral Neck System) Locking Plate hi implant thar tak a ni a, ke ruh tliak te fixation atana siam a ni. A hian traditional multiple screw construct atanga paradigm shift a entir a, angular stability nei standardized, simplified implant a pe a ni.

fns-locking-plate-chuan-femoral-neck-fracture-fixation-ah a awm a

5.0 Locking Screw hmanga siam a ni

5.0mm Locking Screw hi FNS Locking Plate chu femoral shaft-a nghet taka dah theihna tura siam a ni.

fns-5-0mm-locking-screws-a-hip-fracture-system-a hman theih a ni

FNS Bolts+Antirotation Screw hmanga siam a ni

Hei hi FNS system-a dynamic compression leh anti-rotation function danglam tak pe theitu core implant combination a ni.

The Bolt: Hei hi plate kaltlangin femoral head chhunga dah luh ber implant a ni.

The Antirotation Screw: Main bolt nen parallel-a dah a nih avangin he screw hian a bul berah chuan femoral head fragment a inher loh nan hna a thawk a ni.

fns-bolt-leh-anti-rotation-screw-te chu femoral-lu-stability-na atan

       

FNS Instrument Set 3300-04 ah a awm a

FNS Instrument Set (3300-04) hi surgical toolkit kimchang leh uluk taka siam a ni a, FNS system chu a dik, a tha a, a siam chhuah theih a ni.

fns-instrument-set-model-3300-04-orthopaedic-surgical-a hmanraw hman te

hming specification hrang hrang a awm REF(titanium hmanga siam) a ni.

FNS Locking Plate (130° CCD angle) (5.0 Locking Screw hmang rawh)

1 khur a ni 3300-0101 ah biak theih a ni
2 a awm 3300-0102 ah zawhfiah theih a ni
FNS Bolts+Antirotation Screw hmanga siam a ni 75mm a ni 3300-0201 ah biak theih a ni
80mm a ni 3300-0202 ah biak theih a ni
85mm a ni 3300-0203 ah biak theih a ni
90mm a ni 3300-0204 ah biak theih a ni
95mm a ni 3300-0205 ah biak theih a ni
100mm a ni 3300-0206 ah biak theih a ni
105mm a ni 3300-0207 ah biak theih a ni
110mm a ni 3300-0208 ah biak theih a ni
115mm a ni 3300-0209 ah biak theih a ni


DFN Distal Femur Intramedullary Nail (Spiral Blade Screw chi hrang hrang) hmanga siam a ni.

FNS Orthopedic System atanga thil siam chhuah thlalak leh thlalak tak tak

fns-femoral-neck-fracture-fixation-surgical-a entir a ni


DFN Distal Femur Intramedullary Nail (Spiral Blade Screw chi hrang hrang) hmanga siam a ni.

FNS System chungchanga Clinical Knowledge leh Zirna hmanrua te

FNS (Femoral Neck System): A tlangpuiin a sawi

Femoral neck hi thigh bone atanga hip joint nena inzawm a ni. He hmuna hliam hi a na thei hle a, operation pawh a ngai thei bawk. Surgery tih theih pakhat chu Femoral Neck System (FNS) a ni a, hei hi femoral neck ruh tliak enkawlna atana hman thin damdawi a ni. He thuziak ah hian FNS chungchang tlangpui kan sawi dawn a, a hlawkna, a hlauhawmna leh a dam lehna kalphung te pawh kan sawi dawn a ni.

FNS chu eng nge ni?

FNS hi medical device a ni a, femoral neck fracture te fixation leh stabilization pe thei tura siam a ni. He device hi plate leh screw hmanga siam a ni a, chu chu ruh tliak chu tihngheh nan hman a ni. He system hi minimally invasive tura siam a ni a, hei hian incision tenau zawk a mamawh tihna a ni a, traditional open surgery nena khaikhin chuan a chhehvel tissue-ah trauma a thlen tlem zawk tihna a ni.

FNS hlawkna

FNS hman hian hlawkna engemaw zat a pe a, chung zingah chuan:

  • Dam chak zawk: He procedure hi minimally invasive nature a nih avangin damlote chu traditional open surgery aiin an dam chak zawk thei a ni.

  • Natna tihtlem: Incision te zawk leh traumatic procedure tlem zawk hian operation hnua natna a ti tlem thei.

  • Harsatna awm theihna a tlem zawk: FNS hian natna hrik kai, nerve tihchhiatna, thisen tlakchhamna te a nei tlem zawk.

  • Mobility tihchangtlun: FNS hian traditional open surgery aiin a natna hmuna mobility leh function siam that lehna kawngah a pui thei a ni.


Risk leh complication awm thei te

Surgery dang ang bawkin FNS hman hian hlauhawm leh harsatna a awm thei a ni. Chung zingah chuan:

  • Infection: Incision awmna hmunah emaw, plate dahna atana screw hman vel emaw ah natna kai theihna a awm.

  • Implant failure: Hun kal zelah plate chu a lo chhuak emaw, a chhe emaw thei a, operation dang neih belh a ngai bawk.

  • Nerve emaw thisen kalna kawng emaw tihchhiat: Surgery tih hian a chhehvela nerve emaw thisen kalna kawng emaw a tichhe thei a, ke emaw ke emaw a ti na emaw, a ti na emaw a tichhe thei a ni.

  • Allergic reaction: Damlo thenkhat chuan plate-a metal hman chu allergic reaction an nei thei.

I orthopaedic surgeon chuan heng hlauhawm leh harsatna te hi i tih hmain a sawipui ang che a, harsatna awm thei tur tihtlem nan hma a la ang.


Recovery kalpui dan tur

Procedure zawhah chuan i ke natna chu hun engemaw chen chu rit lo turin an hrilh ang che. Mobility-a pui turin crutches emaw walker emaw pek i ni thei bawk. Ke natna chu chakna leh hnathawhna siamhatna tura pui turin physical therapy pawh pek theih a ni bawk. Hliam nasat dan leh damlo pakhat zel a zirin dam hun hi a inang lo thei a, mahse a tlangpuiin a dam kim theih nan kar engemaw zat atanga thla engemaw zat a ngai a ni.

FNS Femoral Neck System chungchanga zawhna tam tak awm thin

FNS Femoral Neck System hi eng atan nge hman a nih? 

FNS (Femoral Neck System) hi femoral neck fracture internal fixation atan hman a ni. Fracture stabilize turin siam a ni a, angular stability a pe thei a, ruh damna a pui bawk a, chutih rualin femoral head a humhim bawk. 

FNS system atan hian eng ang femoral neck fracture nge tih tur? 

FNS system hi femoral neck fracture, stable internal fixation mamawh, a bik takin undisplaced emaw minimally displaced fracture te, leh clinically femoral head humhalh duhna case te tan hman a ni.

Engtin nge FNS system hi traditional cannulated screw fixation nen a danglam? 

Traditional cannulated screw nena khaikhin chuan FNS system hian fixation bolt, anti-rotation screw leh locking plate te inzawmkhawm hmangin angular leh rotational stability a ti tha zawk a, fixation failure hlauhawmna a tihziaawm thei a ni. 

FNS system hi minimally invasive surgery atan a tha em? 

Awle. FNS Femoral Neck System hi minimally invasive surgical techniques support thei tura siam a ni a, incision tenau zawk siam theihna tur, soft tissue tihbuai tihtlem theihna tur leh postoperative recovery rang zawka awm theihna tur a ni. 

FNS Femoral Neck System-ah hian eng thil nge hman? 

FNS system hi medical-grade titanium alloy hmanga siam a ni a, orthopaedic implantation atan chakna sang tak, corrosion resistance leh biocompatibility a pe a ni. 

FNS system hian fracture hmunah controlled compression a pe thei ang em? 

Awle. FNS system design hian fracture site-ah controlled dynamic compression a siam thei a, hei hian fracture healing a tichak thei a, chutih rualin femoral neck shortening lutuk pawh a ti tlem thei bawk. 

FNS Femoral Neck System-a thil pawimawh ber berte chu engte nge ni? 

He system hi anatomically contoured locking plate, central fixation bolt, anti-rotation screw, 5.0 mm locking screw, leh implantation dik tak atana instrument set bik a awm a ni. 

FNS system nena inzawm risk emaw complication awm thei te chu engte nge ni? 

A hlauhawmna awm thei chu infection, union emaw nonunion emaw tihkhawtlai, implant looseing emaw breakage emaw, femoral head necrosis, leh revision surgery neih a ngai te a ni. Heng hlauhawmnate tihziaawmna atan hian damlo thlan dan dik leh surgical technique dik tak a pawimawh hle. 

FNS system hi ruh natna vei tan a tha em? 

Osteoporosis na tak nei damlote tan chuan fixation stability a tichhe thei a ni. FNS system hi a remchan leh remchan loh chu ruh quality leh ruh tliak dan a zirin uluk takin surgeon-in a zirchiang tur a ni. 

FNS system hian surgical instrument bik a mamawh em? 

Awle. FNS system hian dedicated instrument set (Model 3300-04) a hmang a, hei hi guide wire dik taka dah, reaming, leh controlled implant insertion te pui thei tura duan a ni. 

FNS Femoral Neck System supply hi sterile a ni em? 

FNS system hi non-sterile-a supply a ni a, clinical-a hman hmain standard hospital protocol angin tihfai leh sterilized a ngai a ni. 

CZMEDITECH hian FNS system atan hian OEM emaw distributor emaw support a pe thei ang em?  

Awle. CZMEDITECH hian FNS Femoral Neck System atan hian OEM leh ODM service, technical support, leh distributor thawhhona a pe a ni. Chipchiar zawka hriat duh chuan CZMEDITECH orthopaedic expert te nena inrawnkhawm a tha.        


DFN Distal Femur Intramedullary Nail (Spiral Blade Screw chi hrang hrang) hmanga siam a ni.

Surgical Technique leh FNS System Video hmanga entir

CZMEDITECH-Gamma Nail hmanga siam a ni

He video hian medical technology solution lama thil thar siamtu lar tak CZMEDITECH atanga Gamma Nail product a pholang a ni. Kan Gamma Nail hi orthopaedic procedure-a precision leh rintlak taka siam a ni.


DFN Distal Femur Intramedullary Nail (Spiral Blade Screw chi hrang hrang) hmanga siam a ni.


DFN Distal Femur Intramedullary Nail (Spiral Blade Screw chi hrang hrang) hmanga siam a ni.




底 tih a ni



Hma chiah: 
Dawtchiah: 

I CZMEDITECH Orthopaedic Expert te zawt rawh

Quality delivery-a harsatna awmte pumpelh turin kan pui che a, i orthopaedic mamawh chu a ngai pawimawh hle a, a hun takah leh budget-ah.
Changzhou-a Meditech Technology Co., Ltd. chuan a rawn ti a.

Thawhna

Tunah hian zawt rawh
© COPYRIGHT 2023 CHANGZHOU MEDITECH TECHNOLOGY CO., LTD., a hnuaia mi ang hian a hlawhtling hle. DIKNA ENGKIM A NI.