3300-01 ah zawh theih a ni
CZMEDITECH a ni
Titanium Alloy hmanga siam a ni
1 set a ni
CE, ISO 13485 a ni
FedEx, DHL, TNT, EMS, etc. te pawh a awm bawk.
OEM leh ODM a awm bawk
Quality guarantee, technical support, fast response, returns & maintenance te a awm bawk.
Femoral neck fracture a awm chuan internal fixation hman a ni
Anatomically contoured design a ni a, a fit tha ber tur a ni.
Fixation nghet tak leh micromotion tihtlem a ni.
Minimally invasive technique nena inmil.
Soft tissue irritation tih tlem nan surface smooth.
| A awm theih dan: | |
|---|---|
FNS (Femoral Neck System) tih hi a awm a.
FNS system hi medical device a ni a, femoral neck region-a fracture awmte chu hun eng emaw chen atana siam that, siamthat emaw stabilize emaw tura ruahman a ni. Anatomically contoured locking plate, central fixation bolt, anti-rotation screws, leh soft tissue tihbuai tlem ber nen precise placement support turin dedicated instrumentation te a awm a ni. CZMeditech Minimally invasive design hian incision tenau zawk, a chhehvel tissue-a trauma tihtlem, leh perioperative recovery period rei zawk, traditional open procedure nena khaikhin chuan a phalsak a ni.
Femoral neck fractures a awm chuan stable internal fixation a ngai a ni
Femoral head humhalh duhna hmuna fracture pattern
Damlo puitlingah chuan minimal invasive internal fixation hman a ngai a ni
Heng indication te hi product description-a tarlan hman tum nen a inmil a ni.
FNS system hi ruh quality tihchhiat nasa tak avanga internal fixation-in stabilization tha tak a pek theih lohna hmunah emaw, surgical site-a active infection-ah emaw hman loh tur a ni. Contraindication bikte chu:
Fracture awm lo dinhmun
Active systemic emaw localized emaw infection a awm thei
Case-a bone stock tling lo, internal fixation atana tha lo
Damlo endikna dik leh surgical judgment hian device hman dan tur a kaihruai tur a ni.
Clinical decision-ah chuan damlo bikte ngaihtuah a ngai a, chung zingah chuan ruh quality, comorbidities, leh overall fracture complexity te pawh a tel. Surgeon-te chuan implant thlan leh dah dan chu an siam ṭhat a ngai a, chu chuan mechanical failure emaw postoperative complication emaw avanga hlauhawmna awm thei chu a ti tlem thei ang. Positioning leh alignment dik tak neih theih nan surgical imaging leh intraoperative monitoring te hi a tha hle.
Sepsis natna (Sepsis) a awm
Malignant primary emaw metastatic tumor emaw a awm thei
Material sensitivity a ni
Vascularity tihchhiat a ni
Internal fixation device leh surgical procedure dang ang bawkin risk a awm thei. Thil ha lo thleng thei tlangpui chu:
Incision site ah natna hrik a awm
Implant loose emaw, a chhe emaw
Union emaw nonunion emaw tihkhawtlai
Soft tissue a ti na thei
Nerve emaw vessel emaw hliam hun eng emaw chen emaw, a awm reng emaw
Implant material atanga allergy awm thei
I orthopaedic surgeon chuan operation hmain hlauhawmna awm thei leh harsatna awm thei tih tlem dan tur a sawiho ang.

FNS (Femoral Neck System) Locking Plate hi implant thar tak a ni a, ke ruh tliak te fixation atana siam a ni. A hian traditional multiple screw construct atanga paradigm shift a entir a, angular stability nei standardized, simplified implant a pe a ni.
5.0mm Locking Screw hi FNS Locking Plate chu femoral shaft-a nghet taka dah theihna tura siam a ni.
Hei hi FNS system-a dynamic compression leh anti-rotation function danglam tak pe theitu core implant combination a ni.
The Bolt: Hei hi plate kaltlangin femoral head chhunga dah luh ber implant a ni.
The Antirotation Screw: Main bolt nen parallel-a dah a nih avangin he screw hian a bul berah chuan femoral head fragment a inher loh nan hna a thawk a ni.
FNS Instrument Set (3300-04) hi surgical toolkit kimchang leh uluk taka siam a ni a, FNS system chu a dik, a tha a, a siam chhuah theih a ni.
| hming | specification hrang hrang a awm | REF(titanium hmanga siam) a ni. |
FNS Locking Plate (130° CCD angle) (5.0 Locking Screw hmang rawh) |
1 khur a ni | 3300-0101 ah biak theih a ni |
| 2 a awm | 3300-0102 ah zawhfiah theih a ni | |
| FNS Bolts+Antirotation Screw hmanga siam a ni | 75mm a ni | 3300-0201 ah biak theih a ni |
| 80mm a ni | 3300-0202 ah biak theih a ni | |
| 85mm a ni | 3300-0203 ah biak theih a ni | |
| 90mm a ni | 3300-0204 ah biak theih a ni | |
| 95mm a ni | 3300-0205 ah biak theih a ni | |
| 100mm a ni | 3300-0206 ah biak theih a ni | |
| 105mm a ni | 3300-0207 ah biak theih a ni | |
| 110mm a ni | 3300-0208 ah biak theih a ni | |
| 115mm a ni | 3300-0209 ah biak theih a ni |


Femoral neck hi thigh bone atanga hip joint nena inzawm a ni. He hmuna hliam hi a na thei hle a, operation pawh a ngai thei bawk. Surgery tih theih pakhat chu Femoral Neck System (FNS) a ni a, hei hi femoral neck ruh tliak enkawlna atana hman thin damdawi a ni. He thuziak ah hian FNS chungchang tlangpui kan sawi dawn a, a hlawkna, a hlauhawmna leh a dam lehna kalphung te pawh kan sawi dawn a ni.
FNS hi medical device a ni a, femoral neck fracture te fixation leh stabilization pe thei tura siam a ni. He device hi plate leh screw hmanga siam a ni a, chu chu ruh tliak chu tihngheh nan hman a ni. He system hi minimally invasive tura siam a ni a, hei hian incision tenau zawk a mamawh tihna a ni a, traditional open surgery nena khaikhin chuan a chhehvel tissue-ah trauma a thlen tlem zawk tihna a ni.
FNS hman hian hlawkna engemaw zat a pe a, chung zingah chuan:
Dam chak zawk: He procedure hi minimally invasive nature a nih avangin damlote chu traditional open surgery aiin an dam chak zawk thei a ni.
Natna tihtlem: Incision te zawk leh traumatic procedure tlem zawk hian operation hnua natna a ti tlem thei.
Harsatna awm theihna a tlem zawk: FNS hian natna hrik kai, nerve tihchhiatna, thisen tlakchhamna te a nei tlem zawk.
Mobility tihchangtlun: FNS hian traditional open surgery aiin a natna hmuna mobility leh function siam that lehna kawngah a pui thei a ni.
Surgery dang ang bawkin FNS hman hian hlauhawm leh harsatna a awm thei a ni. Chung zingah chuan:
Infection: Incision awmna hmunah emaw, plate dahna atana screw hman vel emaw ah natna kai theihna a awm.
Implant failure: Hun kal zelah plate chu a lo chhuak emaw, a chhe emaw thei a, operation dang neih belh a ngai bawk.
Nerve emaw thisen kalna kawng emaw tihchhiat: Surgery tih hian a chhehvela nerve emaw thisen kalna kawng emaw a tichhe thei a, ke emaw ke emaw a ti na emaw, a ti na emaw a tichhe thei a ni.
Allergic reaction: Damlo thenkhat chuan plate-a metal hman chu allergic reaction an nei thei.
Procedure zawhah chuan i ke natna chu hun engemaw chen chu rit lo turin an hrilh ang che. Mobility-a pui turin crutches emaw walker emaw pek i ni thei bawk. Ke natna chu chakna leh hnathawhna siamhatna tura pui turin physical therapy pawh pek theih a ni bawk. Hliam nasat dan leh damlo pakhat zel a zirin dam hun hi a inang lo thei a, mahse a tlangpuiin a dam kim theih nan kar engemaw zat atanga thla engemaw zat a ngai a ni.
FNS (Femoral Neck System) hi femoral neck fracture internal fixation atan hman a ni. Fracture stabilize turin siam a ni a, angular stability a pe thei a, ruh damna a pui bawk a, chutih rualin femoral head a humhim bawk.
FNS system hi femoral neck fracture, stable internal fixation mamawh, a bik takin undisplaced emaw minimally displaced fracture te, leh clinically femoral head humhalh duhna case te tan hman a ni.
Traditional cannulated screw nena khaikhin chuan FNS system hian fixation bolt, anti-rotation screw leh locking plate te inzawmkhawm hmangin angular leh rotational stability a ti tha zawk a, fixation failure hlauhawmna a tihziaawm thei a ni.
Awle. FNS Femoral Neck System hi minimally invasive surgical techniques support thei tura siam a ni a, incision tenau zawk siam theihna tur, soft tissue tihbuai tihtlem theihna tur leh postoperative recovery rang zawka awm theihna tur a ni.
FNS system hi medical-grade titanium alloy hmanga siam a ni a, orthopaedic implantation atan chakna sang tak, corrosion resistance leh biocompatibility a pe a ni.
Awle. FNS system design hian fracture site-ah controlled dynamic compression a siam thei a, hei hian fracture healing a tichak thei a, chutih rualin femoral neck shortening lutuk pawh a ti tlem thei bawk.
He system hi anatomically contoured locking plate, central fixation bolt, anti-rotation screw, 5.0 mm locking screw, leh implantation dik tak atana instrument set bik a awm a ni.
A hlauhawmna awm thei chu infection, union emaw nonunion emaw tihkhawtlai, implant looseing emaw breakage emaw, femoral head necrosis, leh revision surgery neih a ngai te a ni. Heng hlauhawmnate tihziaawmna atan hian damlo thlan dan dik leh surgical technique dik tak a pawimawh hle.
Osteoporosis na tak nei damlote tan chuan fixation stability a tichhe thei a ni. FNS system hi a remchan leh remchan loh chu ruh quality leh ruh tliak dan a zirin uluk takin surgeon-in a zirchiang tur a ni.
Awle. FNS system hian dedicated instrument set (Model 3300-04) a hmang a, hei hi guide wire dik taka dah, reaming, leh controlled implant insertion te pui thei tura duan a ni.
FNS system hi non-sterile-a supply a ni a, clinical-a hman hmain standard hospital protocol angin tihfai leh sterilized a ngai a ni.
Awle. CZMEDITECH hian FNS Femoral Neck System atan hian OEM leh ODM service, technical support, leh distributor thawhhona a pe a ni. Chipchiar zawka hriat duh chuan CZMEDITECH orthopaedic expert te nena inrawnkhawm a tha.

He video hian medical technology solution lama thil thar siamtu lar tak CZMEDITECH atanga Gamma Nail product a pholang a ni. Kan Gamma Nail hi orthopaedic procedure-a precision leh rintlak taka siam a ni.



Thil siam chhuah te