No. | REF | Products | Qty |
1 | 3200-0501 | Alumium Box & Screw Rack | 1 |
2 | 3200-0502 | Multi-axial Cone Guider Ø2.1 | 1 |
3 | 3200-0503 | Multi-axial Cone Guider Ø2.0 | 1 |
4 | 3200-0504 | Depth Gauge | 1 |
5 | 3200-0505 | Torx Head Screwdriver T8 | 1 |
6 | 3200-0506 | Multi-axial Straight Guider Ø2.1 | 1 |
7 | 3200-0507 | Multi-axial Straight Guider Ø2.0 | 1 |
8 | 3200-0508 | Screwdriver Handle | 1 |
9 | 3200-0509 | Drill Sleeve Ø2.0 | 1 |
10 | 3200-0510 | Drill Sleeve Ø2.0 | 1 |
11 | 3200-0511 | Drill Sleeve Ø2.1 | 1 |
12 | 3200-0512 | Drill Sleeve Ø2.1 | 1 |
13 | 3200-0513 | Plate Bender 2.4/2.7mm | 1 |
14 | 3200-0514 | Plate Bender 2.4/2.7mm | 1 |
15 | 3200-0515 | Drill Guider Ø2.1/2.7 | 1 |
16 | 3200-0516 | Drill Guider Ø2.0/2.4 | 1 |
17 | 3200-0517 | AO Drill Bit Ø2.0mm | 1 |
18 | 3200-0518 | AO Drill Bit Ø2.0mm | 1 |
19 | 3200-0519 | AO Drill Bit Ø2.1mm | 1 |
20 | 3200-0520 | AO Drill Bit Ø2.1mm | 1 |
21 | 3200-0521 | Drill Guider Ø2.1/2.7 | 1 |
22 | 3200-0522 | Drill Guider Ø2.0/2.4 | 1 |
23 | 3200-0523 | Torque Wrench 0.8N.m. | 1 |
24 | 3200-0524 | Screw Holding Sleeve | 1 |
25 | 3200-0525 | Countersink Drill Ø2.4 | 1 |
26 | 3200-0526 | Countersink Drill Ø2.7 | 1 |
27 | 3200-0527 | Torx Head Screwdriver T8 (Quick-coupling) | 1 |
28 | 3200-0528 | Quick Coupling Tap HC2.4 | 1 |
29 | 3200-0529 | Quick Coupling Tap HA2.4 | 1 |
30 | 3200-0530 | Quick Coupling Tap HA2.7 | 1 |
31 | 3200-0531 | Quick Coupling Tap HC2.7 | 1 |
32 | 3200-0532 | Guider Pin | 1 |
33 | 3200-0533 | Guider Pin | 1 |
34 | 3200-0534 | Aluminium Box | 1 |
Actual Picture
Blog
The 2.4/2.7 multi-axial locking plates instrument set is a specialized tool used in orthopedic surgery to treat fractures and deformities in the bone. This instrument set is designed to provide greater stability and strength compared to traditional bone fixation techniques, allowing for better outcomes and faster recovery times.
The 2.4/2.7 multi-axial locking plates instrument set includes several components, including:
The locking plates are made of titanium alloy and feature a multi-axial locking system. This system allows the screws to be inserted at an angle, providing greater stability and fixation.
The screws used with the locking plates are also made of titanium alloy and feature a self-tapping design. This allows for easier insertion into the bone and reduces the risk of screw loosening or failure.
The drill guides are used to ensure accurate placement of the screws into the bone. They are designed to fit the locking plates precisely and help prevent damage to surrounding tissues and structures.
The instrument set also includes various instruments, such as screwdrivers and pliers, used to insert and manipulate the screws and locking plates.
The 2.4/2.7 multi-axial locking plates instrument set has several advantages over traditional bone fixation techniques. Some of these include:
The multi-axial locking system of the plates and screws provides greater stability and strength compared to traditional bone fixation techniques, allowing for better outcomes and faster recovery times.
The self-tapping design of the screws used with the locking plates reduces the risk of screw loosening or failure, providing greater durability and reliability.
The locking plates are available in various sizes and shapes, allowing for a customized fit to the patient's anatomy. This can lead to improved outcomes and reduced complications.
While the use of the 2.4/2.7 multi-axial locking plates instrument set has several advantages, there are potential risks and complications associated with its use. Some of these include:
As with any surgical procedure, there is a risk of infection. This risk can be minimized by adhering to strict aseptic techniques and using sterile instruments.
In some cases, the bone may not heal properly, leading to non-union or mal-union. This can occur if the bone is not properly stabilized during the healing process.
The locking plate and screw system used in the instrument set can fail if the screws become loose or the plate breaks. This can lead to pain and the need for revision surgery.
The 2.4/2.7 multi-axial locking plates instrument set is a specialized tool used in orthopedic surgery to treat fractures and deformities in the bone. While there are potential risks and complications associated with its use, the benefits of using this instrument set far outweigh the risks. The increased stability and strength provided by the multi-axial locking system can lead to better outcomes and faster recovery times, making it an essential tool in modern orthopedic surgery.
Is the 2.4/2.7 multi-axial locking plates instrument set used in all bone fixation procedures?
No, the instrument set is designed for specific types of bone fixation procedures, such as fractures and deformities in the bone.
How long does it take to recover from a bone fixation procedure using the instrument set?
Recovery time varies depending on the type and complexity of the bone fixation procedure. Patients can expect to undergo physical therapy and rehabilitation to aid in their recovery.
Are there any restrictions on activities after a bone fixation procedure using the instrument set?
Patients may be advised to avoid high-impact activities or activities that put excessive strain on the affected area for a certain period of time, depending on the nature of the procedure and their individual recovery progress.
Can the locking plates and screws be removed after the bone has healed?
In some cases, the locking plates and screws can be removed after the bone has healed. This decision is typically made by the surgeon based on the patient's individual circumstances and the nature of the procedure.
How common are complications associated with the use of the instrument set?
Complications associated with the use of the instrument set are rare but can occur. These risks can be minimized by adhering to strict surgical techniques and closely monitoring patients during the recovery process.