3200-08
CZMEDITECH
Availability: | |
---|---|
Quantity: | |
Product Video
Features & Benefits
Specification
No. | REF | Products | Qty |
1 | 3200-0801 | Qucik Coupling Drill Bit Ø3.5*150 | 1 |
2 | 3200-0802 | Qucik Coupling Drill Bit Ø3.5*150 | 1 |
3 | 3200-0803 | Qucik Coupling Tap HC.0*220 | 1 |
4 | 3200-0804 | Qucik Coupling Drill Bit Ø4.3*280 | 2 |
5 | 3200-0805 | Osteotome 10mm | 1 |
6 | 3200-0806 | Osteotome 15mm | 1 |
7 | 3200-0807 | Osteotome 20mm | 1 |
8 | 3200-0808 | Osteotome 25mm | 1 |
9 | 3200-0809 | Pointed Kirschner Wire Ø2.0*280 | 2 |
10 | 3200-0810 | Pointed Kirschner Wire Ø2.5*280 | 2 |
11 | 3200-0811 | Drill Bit KirschnerWwire Ø2.5*300 | 2 |
12 | 3200-0812 | Depth Gauge 0-120mm | 1 |
13 | 3200-0813 | Section Height Monitor | 1 |
14 | 3200-0814 | Angle Measurer | 1 |
15 | 3200-0815 | Torque Handle 4.0N.m | 1 |
16 | 3200-0816 | Spring Drill Ø3.5/4.3 | 1 |
17 | 3200-0817 | Straight Quick Coupling Handle | 1 |
18 | 3200-0818 | Measuring Ruler | 1 |
19 | 3200-0819 | Quick coupling Hex Screwdriver SW3.5*100 | 1 |
20 | 3200-0820 | Tap Guide Drill Sleeve Ø5.0*100 | 1 |
21 | 3200-0821 | Guide Pin Duide Ø2.0 | 1 |
22 | 3200-0822 | Guide Pin Duide Ø2.0 | 1 |
23 | 3200-0823 | Drill-oriented Drill Sleeve Ø4.3*150 | 1 |
24 | 3200-0824 | Drill-oriented Drill Sleeve Ø4.3*150 | 1 |
25 | 3200-0825 | Aluminium Box | 1 |
Actual Picture
Blog
Osteotomy is a surgical procedure that involves cutting or reshaping bone to treat various conditions such as deformities, trauma, and degenerative diseases. Osteotomy procedures require specialized instruments to ensure precision and accuracy. One of the most important tools used in osteotomy surgery is the locking plate instrument set. In this article, we will take a closer look at the osteotomy locking plate instrument set, its components, and its importance in surgical procedures.
An osteotomy locking plate instrument set is a collection of surgical instruments specifically designed to aid in the osteotomy surgical procedure. The set includes various tools that enable surgeons to make precise and accurate bone cuts and secure them in place with locking plates.
An osteotomy locking plate instrument set typically includes the following components:
A bone saw is a specialized surgical saw designed for cutting through bone. In osteotomy procedures, bone saws are used to make precise cuts in the bone to reshape or realign it.
An osteotome is a chisel-like surgical instrument used to cut through bone. Osteotomes come in various shapes and sizes and are used to reshape bone during osteotomy procedures.
A surgical drill is used to create holes in bone for the insertion of screws or other fixation devices. In osteotomy procedures, drills are used to create holes for locking plate screws.
A locking plate is a specialized plate that is used to hold fractured or osteotomized bones in place. The plate is fixed to the bone with screws, and the locking mechanism prevents the screws from loosening.
Locking plate screws are used to secure the locking plate to the bone. These screws are designed to thread into the locking plate and engage with the bone to hold the plate in place.
The osteotomy locking plate instrument set is essential in osteotomy procedures as it enables surgeons to make precise bone cuts and hold them securely in place with locking plates. This set of instruments has revolutionized the field of orthopedic surgery, allowing for safer and more accurate osteotomy procedures.
There are several types of osteotomy locking plate instrument sets available, each designed for a specific type of osteotomy procedure. The most common types include:
This instrument set is specifically designed for tibial osteotomy procedures. The set includes specialized plates, screws, and instruments for the precise reshaping of the tibia bone.
This instrument set is designed for femoral osteotomy procedures. The set includes specialized plates, screws, and instruments for the precise reshaping of the femur bone.
This instrument set is designed for maxillofacial osteotomy procedures. The set includes specialized plates, screws, and instruments for the precise reshaping of the bones in the face and jaw.
The use of the osteotomy locking plate instrument set has several advantages over traditional osteotomy techniques, including:
The use of specialized instruments in the osteotomy locking plate instrument set allows for more precise bone cuts and greater accuracy in bone reshaping.
The locking plate and screw system used in the osteotomy locking plate instrument set provides greater stability and reduces the risk of post-operative complications such as non-union or mal-union.
While the use of the osteotomy locking plate instrument set has several advantages, there are potential risks and complications associated with its use. Some of these include:
As with any surgical procedure, there is a risk of infection. This risk can be minimized by adhering to strict aseptic techniques and using sterile instruments.
In some cases, the bone may not heal properly, leading to non-union or mal-union. This can occur if the bone is not properly stabilized during the healing process.
The locking plate and screw system used in the osteotomy locking plate instrument set can fail if the screws become loose or the plate breaks. This can lead to pain and the need for revision surgery.
The osteotomy locking plate instrument set is an essential tool in modern orthopedic surgery. Its use has revolutionized the field of osteotomy procedures, allowing for safer and more accurate bone reshaping. While there are potential risks and complications associated with its use, the benefits of using this instrument set far outweigh the risks.
Is the osteotomy locking plate instrument set used in all osteotomy procedures?
No, the instrument set is designed for specific types of osteotomy procedures, such as tibial, femoral, and maxillofacial osteotomy.
Can the locking plate and screw system fail?
Yes, the locking plate and screw system can fail if the screws become loose or the plate breaks. This can lead to pain and the need for revision surgery.
How long does it take to recover from an osteotomy procedure?
Recovery time varies depending on the type and complexity of the osteotomy procedure. Patients can expect to take several weeks to months to fully recover.
Are there any alternative techniques to the osteotomy locking plate instrument set?
Yes, there are alternative techniques, such as traditional osteotomy techniques or external fixation devices. However, the osteotomy locking plate instrument set has several advantages over these techniques.
Can osteotomy procedures be performed using minimally invasive techniques?
Yes, some osteotomy procedures can be performed using minimally invasive techniques, which may result in faster recovery times and less scarring. However, not all osteotomy procedures are suitable for minimally invasive techniques.