3200-10
CZMEDITECH
Availability: | |
---|---|
Quantity: | |
Product Video
Features & Benefits
Specification
NO. | REF | Description | Qty. |
1 | 3200-1001 | 1.5mm PlateTray | 1 |
2 | 3200-1002 | 2.0mm Plate Tray | 1 |
3 | 3200-1003 | 2.4mm Plate Tray | 1 |
4 | 3200-1004 | 1.5mm Plate Holder | 2 |
5 | 3200-1005 | 1.1mm AO Drill Bit | 1 |
6 | 3200-1006 | T5 Stardriver | 1 |
7 | 3200-1007 | 3.0mm Countersink | 1 |
8 | 3200-1008 | 1.5mm AO Tap | 1 |
9 | 3200-1009 | 1.1/1.5 Guider | 1 |
10 | 3200-1010 | 1.1mm Locking Sleeve | 1 |
11 | 3200-1011 | 1.1mm Locking Sleeve | 1 |
12 | 3200-1012 | 2.0mm Plate Holder | 2 |
13 | 3200-1013 | 1.5mm AO Drill Bit | 1 |
14 | 3200-1014 | T6 Stardriver | 1 |
15 | 3200-1015 | 2.0mm AO Tap | 1 |
16 | 3200-1016 | 4.0mm Countersink | 1 |
17 | 3200-1017 | 1.5/2.0 Guider | 1 |
18 | 3200-1018 | 1.5mm Locking Sleeve | 1 |
19 | 3200-1019 | 1.5mm Locking Sleeve | 1 |
20 | 3200-1020 | 2.4mm Plate Holder | 2 |
21 | 3200-1021 | 2.0mm AO Drill Bit | 1 |
22 | 3200-1022 | T8 Stardriver | 1 |
23 | 3200-1023 | 4.5mm Countersink | 1 |
24 | 3200-1024 | 2.4mm AO Tap | 1 |
25 | 3200-1025 | 2.0/2.4 Guider | 1 |
26 | 3200-1026 | 2.0mm Locking Sleeve | 1 |
27 | 3200-1027 | 2.0mm Locking Sleeve | 1 |
28 | 3200-1028 | Bending Forcep | 1 |
29 | 3200-1029 | Plate Cutter | 1 |
30 | 3200-1030 | 0.4 N.m Torque Wrench | 1 |
31 | 3200-1031 | 0.8 N.m Torque Wrench | 1 |
32 | 3200-1032 | Self-locking Reduction Forcep | 1 |
33 | 3200-1033 | Screwholding Forcep | 1 |
34 | 3200-1034 | AO Quick Coupling Handle | 1 |
35 | 3200-1035 | Tip Reduction Forcep | 1 |
36 | 3200-1036 | Depth Gague 0-30mm | 1 |
37 | 3200-1037 | Depth Gague 0-40mm | 1 |
38 | 3200-1038 | Periosteal Elevator Flat | 1 |
39 | 3200-1039 | Periosteal Elevator Round | 1 |
40 | 3200-1040 | Aluminium Box | 1 |
Actual Picture
Blog
The Mini Fragment Locking Plate Instrument Set is a comprehensive orthopedic surgical instrument set designed for the fixation of fractures, osteotomies, and non-unions in small bones such as the hand, wrist, foot, and ankle. The set consists of various instruments including plates, screws, drills, taps, and instruments for implant placement.
The Mini Fragment Locking Plate Instrument Set offers various features that make it suitable for the fixation of small bone fractures, osteotomies, and non-unions, including:
Comprehensive set: The set contains various instruments required for the fixation of fractures in small bones, reducing the need for additional instruments during surgery.
Locking plate technology: The set includes locking plates that offer superior stability and allow for multiplanar fixation in small bones.
Anatomical plate design: The plates are designed to fit the anatomy of small bones, reducing the risk of implant failure.
Self-drilling and self-tapping screws: The screws included in the set are designed for easy insertion and reduced risk of screw pullout.
Minimally invasive: The set includes instruments that allow for minimally invasive surgery, reducing tissue trauma and promoting faster healing.
The Mini Fragment Locking Plate Instrument Set is used for various surgical applications, including:
Fixation of hand fractures: The set is used for the fixation of phalangeal, metacarpal, and carpal fractures.
Fixation of foot and ankle fractures: The set is used for the fixation of calcaneal, talus, and metatarsal fractures.
Fixation of wrist fractures: The set is used for the fixation of distal radius fractures and scaphoid fractures.
Fixation of non-unions and osteotomies: The set is used for the fixation of non-unions and corrective osteotomies in small bones.
The surgical technique for using the Mini Fragment Locking Plate Instrument Set involves the following steps:
Preoperative planning and patient positioning: Preoperative planning involves the selection of appropriate implants and instruments based on the fracture pattern and patient anatomy. The patient is positioned appropriately for the surgery.
Incision and exposure: A small incision is made over the fracture site, and the bone is exposed using appropriate instruments.
Reduction of fracture: The fracture is reduced using reduction forceps and checked for accuracy using imaging.
Plate placement: The appropriate locking plate is selected and contoured to fit the bone anatomy. The plate is then fixed to the bone using screws.
Screw placement: Self-drilling and self-tapping screws are inserted through the plate into the bone to achieve stable fixation.
Closure: The incision is closed in layers, and a sterile dressing is applied.
Like any surgical procedure, the use of the Mini Fragment Locking Plate Instrument Set may be associated with some complications, including:
Infection
Implant failure
Screw breakage or migration
Nerve or blood vessel damage
Loss of reduction
Non-union or delayed union
However, these complications are rare and can be minimized by careful surgical technique, appropriate patient selection, and close postoperative monitoring.
The Mini Fragment Locking Plate Instrument Set is a comprehensive orthopedic instrument set designed for the fixation of fractures, osteotomies, and non-unions in small bones. The features, surgical applications, and surgical technique for using the set make it an ideal choice for orthopedic surgeons looking to achieve stable and anatomical fixation in small bones. Although there are some potential complications associated with the use of the set, they are rare and can be minimized through careful surgical technique and postoperative monitoring.
What is the Mini Fragment Locking Plate Instrument Set used for?
The Mini Fragment Locking Plate Instrument Set is used for the fixation of fractures, osteotomies, and non-unions in small bones such as the hand, wrist, foot, and ankle.
What are the features of the Mini Fragment Locking Plate Instrument Set?
The Mini Fragment Locking Plate Instrument Set features locking plate technology, anatomical plate design, self-drilling and self-tapping screws, and instruments for minimally invasive surgery.
What are the potential complications associated with the Mini Fragment Locking Plate Instrument Set?
The potential complications associated with the Mini Fragment Locking Plate Instrument Set include infection, implant failure, screw breakage or migration, nerve or blood vessel damage, loss of reduction, and non-union or delayed union.
How can the risk of complications be minimized?
The risk of complications can be minimized through careful surgical technique, appropriate patient selection, and close postoperative monitoring.
Who is qualified to use the Mini Fragment Locking Plate Instrument Set?
The Mini Fragment Locking Plate Instrument Set should only be used by qualified orthopedic surgeons who have received appropriate training and certification.