Zawhna i nei em?        +86- 18112515727 ah      zawhfiah theih a ni  hla@orthopaedic-china.com ah hian a awm a
Please Choose Your Language
Hetah hian i awm: In » Thil siam chhuah te » Spine a ni » Spinal Implant te pawh a awm » Stryker hmanga tihzauh theih Lumbar Cage

loading a ni

Share to:
facebook ah in share theih a ni
twitter hmanga share theih a ni
line insem theihna button a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
whatsapp a insem theihna tur a ni
sharethih hi share theih a ni

Stryker Lumbar Cage tihzauh theih a ni

  • 2300-26 thleng a ni

  • CZMEDITECH a ni

  • Titanium / Titanium Alloy hmanga siam a ni

  • 1 piece a ni

  • CE/ISO:9001/ISO13485 a ni

  • FedEx / DHL / TNT / EMS / etc. te hi a ni

  • OEM leh ODM service a awm bawk

  • Technical support, product training, surgical guidance, leh hun rei tak chhunga hralh hnua service pek te a ni

  • Posterior lumbar interbody fusion (PLIF/TLIF) hmangin degenerative disc natna, spondylolisthesis, stenosis, leh corpectomy siam thar lehna tur a awm a ni. L1–S1, single emaw multi‐level fusion emaw atan tarlan a ni.

  • Expandable design – in‐situ expansion hian disc san zawng leh segmental lordosis a siam tha leh
    Tritanium 3D printing technology – ruh chhunga tihpunna tur high‐porosity, cancellous bone‐like structure
    Multiple approach – PLIF/TLIF, straight or curved profile
    Bi‐directional fixation teeth – solid‐tip serrations for anti‐migration
    Window lian tak tak – fusion assessment atan X‐ray/CT visualization chiang tak
    Size hrang hrang duhthlan tur – kephah, a san zawng, leh lordotic angle hrang hrang

A awm theih dan:

Product Description chungchang

Product chungchang tlangpui

Stryker Expandable Lumbar Cage hian mechanical structure thar, tihzauh theih leh Tritanium 3D‐printed technology hmasawn tak a hmang a ni. He device hian in‐situ expansion hmangin disc height leh segmental lordosis a siam tha leh a, a biomimetic porous structure erawh chu ruh ingrowth leh biological fixation tichak tura duan a ni thung. A hnunglam lumbar interbody fusion (PLIF ) leh transforaminal lumbar interbody fusion ( .TLIF ) a ni.

Clinical Indication hrang hrang a awm bawk

  • Degenerative disc natna leh instability nei lo

  • Grade I‐II ah chuan lumbar spondylolisthesis a awm a

  • Disc herniation lo awm leh tur chu revision surgery neih a ni

  • Spinal stenosis awm theihna tur post‐decompression fusion hmanga tih a ni

  • Corpectomy siam thar lehna (lumbar spine) .

  • Pseudoarthrosis siamthatna tur a ni

Target levels: L1 – S1 (single emaw multi‐level emaw)
Surgery tih dan tur: PLIF / TLIF

Thil pawimawh tak tak

Design tihzauh theih

  • In‐situ expansion – controlled expansion hmangin intervertebral height leh lordosis a siam tha leh thin

  • Insertion height hniam – initial profile te zawk hian minimally invasive placement a ti awlsam

  • Independent control – lordosis siamthat nan hmalam emaw hnunglam emaw expansion thlan theih

Tritanium 3D Printing hmanga siam a ni

  • Proprietary AMagineTM technology – porous architecture dik tak siamna atana additive siamna

  • Biomimetic porosity – pore size leh shape mumal lo, cancellous bone ang chi

  • Pores inzawm kim vek – through‐pores endplate atanga endplate thleng

  • Fluid retention capacity – titanium hlui nena khaikhin chuan fluid retention tha zawk

Cage Design-a thil awmte

  • Lateral window lian tak tak – bone graft packing leh radiographic fusion assessment siam awlsam

  • Bi‐directional fixation teeth – multi‐directional anti‐migration atan solid‐tip serrations te hi a awm a, a chhuahna tur hmun hi a awm lo

  • Curved profile option – Tritanium TL curved cage chu oriented insertion atan hman theih a ni

Size duhthlan tur a awm

  • Footprint size hrang hrang a awm

  • A san zawng: 8 – 14 mm

  • Lordotic angle: 0° / 6° / 12° (12° hyper‐lordotic option te pawh a tel)

Inthlauhna – Stryker Expandable Cage leh Traditional Static Cage te nen khaikhin a ni

Nihphung

Stryker Cage tihzauh theih (Thar) .

Traditional Static Cage (Hmanlai) a ni.

Insertion dan tur

A san zawng hniam taka insertion, in‐situ expansion

Final‐height atanga direct impaction a ni

A san zawng siamthat

Controlled expansion, siamthatna dik tak

Distraction nasa tak a mamawh

Lordosis siamthat lehna

Anterior/posterior expansion thlan theih a ni

Lordotic angle tihfel a ni

Ruh chhunga tihpunna tur thil

Tritanium porous titanium (cancellous ang maia awm) a ni.

PEEK emaw solid titanium emaw a ni thei

Pore ​​awm dan

Pores mumal lo (60‐80% porosity) inzawmkhawm kim vek .

Pores awm lo emaw, surface coating chauh emaw a ni

Radiographic hmanga hmuh theihna

Window lian tak tak + titanium, X‐ray/CT-a chiang taka hmuh theih

PEEK hi radiolucent a ni

Fusion hmanga tehfung siam a ni

Porous structure hmanga ruh ingrowth endikna direct

Indirect sign a mamawh

Anti‐migration design a ni

Bi‐directional solid‐tip serration te chu a awm a

Conventional ha te tak te emaw, a chung lam hrual emaw

Clinical insight: Stryker Expandable Lumbar Cage-a Tritanium technology hian 3D printing hmangin cancellous bone‐like porous structure a siam a, chu chu ruh chhungril leh biological fixation tichak tura duan a ni. Clinical data atanga a lan dan chuan Tritanium cages nen hian fusion rates 91‐96% a ni.

Hrechiang duh tan surgical cases te chu he product hi a ni, khawngaihin min rawn biak theih reng e.

Engvangin Nge CZMEDITECH hi I Stryker Expandable Lumbar Cage Supplier atan I thlan?

  • Minimally invasive friendly – ​​initial height hniam chuan incision tenau zawk insertion a siam thei

  • Precise height restoration – expandable design hian disc san zawng recovery tha zawk a pe a ni

  • Fusion a tichak – Tritanium porous structure chu ruh chhunga tihpunna atana siam a ni

  • Radiographic compatibility – titanium material + postoperative fusion assessment atan window lian tak tak

  • Thil thlan tur tam tak – straight/curved profile, anatomy hrang hrang atan size hrang hrang

  • Clinically validated – fusion rate data support (91‐96%) a ni a, a hlawhtlinna chu a hlawhtlinna a ni.

Zawhna zawh fo thin (FAQ) .

1. Expanable cage leh traditional static cage te hi eng nge an danglamna ber?

Expanable cage chu initial height hniam zawkah dah a ni a, chutah chuan disc space chhungah height duh angin expand a ni. He design hian nerve root retraction a ti tlem a, disc san zawng leh segmental lordosis te chu chiang zawkin a siam tha thei bawk. Traditional static cages hian final height-ah impaction a mamawh a, hei hian insertion harsatna a tipung thei a ni.

2. Tritanium technology chu eng nge ni?

Tritanium hi Stryker-in a siam, high‐porosity titanium material a ni a, AMagineTM 3D printing technology hmanga siam a ni. Cancellous bone morphology ang deuha siam, bone ingrowth leh biological fixation tichak tura siam, irregular, interconnected pores a nei a ni.

3. Expanable cage hian subsidence risk a nei em?

Biomechanical study-ah chuan subsidence depth hi ruh density nen a inzawm tlat tih hmuhchhuah a ni. Expansion torque ang chiah hnuaiah hian ruh density hniam (eg, 5 PCF) chuan subsidence 2.3 mm vel a lantir a, ruh density sang (20 PCF) chuan 1.1 mm vel a lantir thung. Surgeon-te chuan ruh quality a zirin size dik tak an thlang tur a ni a, fimkhur takin an exercise tur a ni.

4. He cage fusion rate hi engzat nge ni?

Clinical data atanga a lan dan chuan thla 12-ah Tritanium cages nen fusion rates 91‐96% a ni. Single‐cage fusion rate chu 91% a ni a, dual‐cage fusion rate chu 96% a ni.

5. Cage MRI hi a inmil em?

Titanium alloy implant hi MR conditional a ni. MRI himna chungchang chiang tak hriat duh chuan product instructions hi en la.

6. Eng size option nge awm?

Footprint size hrang hrang a awm a, a san zawng chu 8‐14 mm a ni a, lordotic angle option chu 0°, 6°, leh 12° (12° hyper‐lordotic option pawh a tel) a ni.

7. Engtin nge cage hian migration a veng?

Cage hian precision‐angled serrations solid tips nei a nei a, bi‐directional anti‐migration capacity pe thei tur leh endplate contact surface area tihpun theihna tura duan a ni.

8. He cage atan hian eng surgical approach nge hman tur?

A bul berah chuan posterior lumbar interbody fusion (PLIF) leh transforaminal lumbar interbody fusion (TLIF) atan hman a ni.

9. Surgical technique manual emaw, pricing information emaw khawi atanga ka hmuh theih ang?

I awmna hmuna Stryker distributor hnenah zawhfiah emaw official website-ah emaw zawhfiah theih a ni. Surgical technique guide kimchang, catalog leh quotation te chu dil theih a ni.


Hma chiah: 
Dawtchiah: 

CZMEDITECH hian a pui che a ni

Fracture hrang hrang tan kan solution zawng zawng zawng rawh.
 
* Spine categroies lian zawng zawng khuh vek tur ;
* Quality leh delivery time lamah customer te thlamuan fo thin ;
* High cost performance kan zawm a,dealer ten profit space an neih theih nan.
Min rawn biak theih reng e

I CZMEDITECH Orthopaedic Expert te zawt rawh

Quality delivery-a harsatna awmte pumpelh turin kan pui che a, i orthopaedic mamawh chu a ngai pawimawh hle a, a hun takah leh budget-ah.
Changzhou-a Meditech Technology Co., Ltd. chuan a rawn ti a.

Thawhna

Tunah hian zawt rawh
© COPYRIGHT 2023 CHANGZHOU MEDITECH TECHNOLOGY CO., LTD., a hlawhtlinna chu a hlawhtlinna a ni. DIKNA ENGKIM A NI.