5100-09
CZMEDITECH
Availability: | |
---|---|
Quantity: | |
Product Description
The distal ulna is an essential component of the distal radioulnar joint, which helps provide rotation to the forearm. The distal ulnar surface is also an important platform for stability of the carpus and the hand. Unstable fractures of the distal ulna therefore threaten both movement and stability of the wrist. The size and shape of the distal ulna, combined with the overlying mobile soft tissues, make application of standard implants difficult. The 2.7 mm Distal Ulna Plate is specifically designed for use in fractures of the distal ulna.
Anatomically contoured to fit the distal ulna
Low profile design helps reduce soft tissue irritation
Accepts both 2.7 mm locking and cortex screws, providing angular stable fixation
Pointed hooks aid in reduction of the ulnar styloid
Angled locking screws allow secure fixation of the ulnar head
Multiple screw options allow a wide range of fracture patterns to be securely stabilized
Available sterile only, in stainless steel and titanium
REF | REF | Specification | Thickness | Width | Length |
VA Distal Lateral Radius Locking Plate (Use 2.7 Locking Screw/2.7 Cortical Screw) | 5100-0901 | 5 holes | 2 | 6.7 | 47 |
5100-0902 | 6 holes | 2 | 6.7 | 55 |
Actual Picture
Blog
Fractures of the distal radius are common injuries that can occur due to falls, sports injuries, or trauma. These injuries can cause severe pain, swelling, and limited mobility of the wrist. To restore the function of the wrist, surgical intervention may be required. One of the most innovative solutions for treating distal radius fractures is the VA Distal Lateral Radius Locking Plate. This article will provide an overview of this innovative treatment option, including its benefits, surgical technique, and outcomes.
The VA Distal Lateral Radius Locking Plate is a surgical implant designed to treat distal radius fractures. It is a locking plate system that is specifically designed to fit the anatomy of the distal radius. The plate is made of titanium, which makes it durable and biocompatible. The locking plate system consists of a plate, screws, and locking mechanism that provides stability to the fractured bone.
The VA Distal Lateral Radius Locking Plate offers several benefits over traditional treatment options for distal radius fractures. The locking mechanism provides excellent stability to the fractured bone, which allows for early mobilization of the wrist. This can lead to a quicker recovery time and better overall outcomes. The plate also provides a precise fit to the anatomy of the distal radius, which can minimize the risk of complications and improve the accuracy of the surgery.
The surgical technique for the VA Distal Lateral Radius Locking Plate is a minimally invasive procedure that involves making a small incision over the wrist. The fractured bone is then reduced, or realigned, using fluoroscopic guidance. The plate is then secured to the bone using screws that are placed in a locked position to provide stability to the bone. The incision is then closed, and a cast or brace may be applied to protect the wrist during the healing process.
Studies have shown that the VA Distal Lateral Radius Locking Plate has excellent outcomes in the treatment of distal radius fractures. Patients who undergo this procedure have reported significant improvements in pain, range of motion, and overall function of the wrist. The locking plate system also has a low rate of complications, such as screw loosening or breakage.
Advancements in the VA Distal Lateral Radius Locking Plate have led to the development of new techniques and implants. For example, some plates are now designed with a pre-contoured shape that matches the anatomy of the distal radius, which can improve the accuracy of the surgery. Other plates are designed with a variable angle locking mechanism that allows for greater flexibility in screw placement.
Recovery and rehabilitation after surgery with the VA Distal Lateral Radius Locking Plate typically involve a combination of physical therapy and home exercises. The aim of rehabilitation is to restore strength and mobility to the wrist and hand. A physical therapist will guide the patient through exercises that promote range of motion and strength building. Patients may also be advised to wear a wrist brace or cast during the recovery period.
Like all surgical procedures, the VA Distal Lateral Radius Locking Plate does carry some risks and potential complications. These can include infection, bleeding, nerve or blood vessel damage, and implant failure. However, the overall rate of complications with this procedure is low, and the benefits often outweigh the risks.
What is the VA Distal Lateral Radius Locking Plate? The VA Distal Lateral Radius Locking Plate is a surgical implant designed to treat distal radius fractures. It is a locking plate system that is specifically designed to fit the anatomy of the distal radius. The plate is made of titanium, which makes it durable and biocompatible. The locking plate system consists of a plate, screws, and locking mechanism that provides stability to the fractured bone.
What are the benefits of using the VA Distal Lateral Radius Locking Plate? The VA Distal Lateral Radius Locking Plate offers several benefits over traditional treatment options for distal radius fractures. The locking mechanism provides excellent stability to the fractured bone, which allows for early mobilization of the wrist. This can lead to a quicker recovery time and better overall outcomes. The plate also provides a precise fit to the anatomy of the distal radius, which can minimize the risk of complications and improve the accuracy of the surgery.
How is the VA Distal Lateral Radius Locking Plate implanted? The surgical technique for the VA Distal Lateral Radius Locking Plate is a minimally invasive procedure that involves making a small incision over the wrist. The fractured bone is then reduced, or realigned, using fluoroscopic guidance. The plate is then secured to the bone using screws that are placed in a locked position to provide stability to the bone.
What are the outcomes of using the VA Distal Lateral Radius Locking Plate? Studies have shown that the VA Distal Lateral Radius Locking Plate has excellent outcomes in the treatment of distal radius fractures. Patients who undergo this procedure have reported significant improvements in pain, range of motion, and overall function of the wrist. The locking plate system also has a low rate of complications, such as screw loosening or breakage.
What is the recovery process like after using the VA Distal Lateral Radius Locking Plate? Recovery and rehabilitation after surgery with the VA Distal Lateral Radius Locking Plate typically involve a combination of physical therapy and home exercises. The aim of rehabilitation is to restore strength and mobility to the wrist and hand. A physical therapist will guide the patient through exercises that promote range of motion and strength building. Patients may also be advised to wear a wrist brace or cast during the recovery period.