Internal fixation for femoral neck fractures
Locking Plate Design for Stable TPLO Fixation
Anatomically Pre-Contoured for Canine Proximal Tibia
High-Strength Titanium or Stainless Steel Material
Compatible with Standard TPLO Surgical Techniques
| Availability: | |
|---|---|
Product Description
The TPLO plate is designed to stabilize the tibia following surgical correction of cranial cruciate ligament (CCL) rupture in dogs. Instead of replacing the ligament, the plate supports biomechanical realignment of the stifle joint, allowing functional stability during weight-bearing.
During tibial plateau leveling osteotomy, the TPLO plate maintains the corrected tibial plateau angle by rigid internal fixation, ensuring controlled healing at the osteotomy site.
A TPLO plate is a veterinary-specific locking bone plate engineered for canine tibial anatomy. Locking screws engage directly with the plate to create a fixed-angle construct.
Unlike conventional plates that rely on friction between plate and bone, TPLO plates function as internal fixators, reducing screw loosening and improving stability in active dogs.
TPLO plates are indicated for dogs suffering from partial or complete cranial cruciate ligament rupture, particularly when joint instability and pain impair normal locomotion.
This system is especially suitable for medium to large breed dogs and physically active animals that require durable fixation and early functional recovery.
Locking screw technology ensures angular stability between the plate and screws, maintaining alignment even under repetitive loading during postoperative movement.
The plate design distributes axial and shear forces evenly across the osteotomy site, minimizing micromotion and supporting consistent bone healing.
TPLO plates are anatomically pre-contoured to fit the medial aspect of the canine proximal tibia, reducing intraoperative plate bending.
Optimized hole placement and screw angulation enhance fixation strength while avoiding critical anatomical structures.
TPLO plates are manufactured from medical-grade titanium alloy or stainless steel, offering high strength, corrosion resistance, and long-term implantation safety.
Advanced surface finishing improves biocompatibility and reduces irritation to surrounding soft tissues.
The TPLO plate system integrates seamlessly with commonly used TPLO surgical instruments, supporting accurate and reproducible procedures.
Standardized locking screws and drill guides ensure precise screw placement and secure fixation.
All TPLO plates are produced under a controlled quality management system covering material sourcing, machining, and final inspection.
Each implant undergoes mechanical strength testing and dimensional verification to ensure consistent clinical performance.
CZMEDITECH provides OEM and ODM customization, including plate dimensions, branding, and packaging.
With scalable manufacturing and global logistics capability, CZMEDITECH supports veterinary distributors worldwide.
It is used to stabilize the tibia after TPLO surgery to restore functional stifle joint mechanics in dogs with CCL rupture.
Most modern TPLO plates use locking screw technology for improved fixation stability.
They are commonly made from titanium alloy or medical-grade stainless steel.
Yes, OEM and private labeling services are available through CZMEDITECH.
Yes, the 2.0/2.4 TPLO Plate Instrument Set is suitable for a wide range of dog breeds, from small to large breeds. The set includes plates and screws of varying sizes, allowing for a customized fit for each dog's unique anatomy.
No, the 2.0/2.4 TPLO Plate Instrument Set is designed specifically for TPLO surgery and is not suitable for other types of orthopedic surgery.
As with any surgical procedure, there are risks associated with TPLO surgery, including infection, bleeding, and complications related to anesthesia. However, using the 2.0/2.4 TPLO Plate Instrument Set can help to minimize these risks by providing a more precise and efficient surgical technique.
Yes, veterinary surgeons can receive training on how to use the 2.0/2.4 TPLO Plate Instrument Set. Many veterinary schools and continuing education programs offer courses and workshops on TPLO surgery and the use of specialized tools such as the 2.0/2.4 TPLO Plate Instrument Set.
The cost of using the 2.0/2.4 TPLO Plate Instrument Set may be slightly higher than traditional TPLO surgery techniques due to the specialized nature of the tools provided. However, the benefits of using the set, including improved precision and efficiency, can lead to better outcomes for the dog and potentially lower long-term costs associated with complications or the need for additional surgeries.
Overall, the 2.0/2.4 TPLO Plate Instrument Set is a valuable tool for veterinary surgeons performing TPLO surgery. Its precision, efficiency, versatility, and reliability provide several benefits over traditional techniques and can greatly improve the outcomes for dogs undergoing this procedure. Additionally, veterinary surgeons can receive training on how to use the set, making it accessible to more practitioners and improving the overall quality of care for dogs undergoing TPLO surgery.
When considering TPLO surgery for your dog, it is important to discuss the various surgical techniques and tools with your veterinarian to determine the best course of action. If TPLO surgery is recommended, ask about the 2.0/2.4 TPLO Plate Instrument Set and its potential benefits for your dog.