5100-33 a ni.
CZMedItech 1000 a ni.
| A awm theihna: | |
|---|---|
Product sawifiahna .
Specification 100 a ni.
| Ref a ni a. | Specification 100 a ni. | Thickness . | Vang | Dung |
| 5100-3301 a ni. | Hole 5 a awm . | 3.2 | 11 | 66 |
| 5100-3302 a ni. | Hole 6 a awm . | 3.2 | 11 | 79 |
| 5100-3303 a ni. | Hole 7 a awm a. | 3.2 | 11 | 92 |
| 5100-3304 a ni. | Hole 8 a awm a. | 3.2 | 11 | 105 |
| 5100-3305 a ni. | Hole 9 a awm a. | 3.2 | 11 | 118 |
| 5100-3306 a ni. | Hole 10 a awm a. | 3.2 | 11 | 131 |
| 5100-3307 a ni. | Hole 12 a awm a. | 3.2 | 11 | 157 |
Thlalak tak tak .

Blog 100 a ni.
Orthopedic injury hi a tam chho zel a, enkawl that loh chuan a tichak lo thei bawk. Heng hliamte enkawlna tha ber pakhat chu plate leh screw hmanga ruh tliakte tihngheh nan leh damna awlsam zawk siam hi a ni. He thuziak ah hian orthopedic surgery-a plate hman tlanglawn tak, straight reconstruction locking plate (SRLP) kan sawi dawn a ni.
SRLP hi orthopedic surgery-a hman thin plate chi khat a ni a, chu chuan ruh tliakte a ti nghet a, damna kawngah a pui bawk. Titanium emaw stainless steel emaw hmanga siam metal plate a ni a, chu chu ruh chung lamah screw hmanga dah a ni. Plate hi low-profile leh contour to the bone a siam a ni a, stability leh support a pe a, motion a ti buai lo emaw, a tikhawlo lo emaw a ni.
SRLP hian orthopedic surgery-a hmanraw tangkai tak a nih theihna tur feature engemaw zat a nei a ni. Heng feature thenkhat te hi:
SRLP hian locking screw a hmang a, hei hian traditional screw aiin stability leh support nasa zawk a pe a ni. Locking screw hian plate chu a kal thei lo emaw, a inthlak emaw thei lo va, chu chuan nonunion emaw malunion emaw ang chi harsatna a awm loh nan a pui thei a ni.
SRLP hi low-profile atana siam a ni a, chu chu ruh chungah flush-in a thu a, a chhehvel tissue-ah a chhuak lo tihna a ni. He design hian harsatna a veng a, motion a tikhawlo a, chu chuan damlo outcome a ti tha thei a ni.
SRLP hi ruh awm dan ang zela contour turin siam a ni a, fit tha zawk leh stability sang zawk a pe thei a ni. He contoured shape hian screw loosening emaw plate migration emaw ang chi complication awm theihna a tihziaawm thei a ni.
SRLP hian screw atan hole tam tak a nei a, hei hian surgery-ah pawh flexibility leh customization nasa zawk a siam thei a ni. Surgeon-te chuan damlo pakhat zel tan optimal screw placement an thlang thei a, chu chu an taksa peng hrang hrang leh hliam an neih dan azirin an thlang thei a ni.
SRLP hi orthopedic surgery hrang hrangah hman a ni a, chung zingah chuan:
SRLP hi ruh tliakte tihngheh nan hman a ni tlangpui a, a bik takin kut leh keah te hman a ni. Plate chu ruh chunglamah dahin screw hmangin an nghet a, ruh a dam laiin support leh stability a pe a ni.
SRLP hi osteotomy procedure-ah pawh hman theih a ni a, chu chuan ruh chu a tan a, a ruh chu a tifai leh a ni. Plate hmang hian ruh chu a awmna thara nghet taka dah theih a ni a, chu chuan a dam tha thei a ni.
SRLP hi arthrodesis procedure-ah hman a ni hin a, chu chu ruh pahnih fuse khawm a ni. Plate hmang hian ruhte chu an inzawm khawm laiin an awmna hmunah an vawng tlat a, chu chuan solid joint a siam a ni.
SRLP hi orthopedic surgery-a hmanraw tangkai tak a nih laiin, a hmanna nena inzawm harsatna a awm thei. Chung harsatna thenkhat chu:
Surgical procedure zawng zawng ang bawkin SRLP hman hian natna kai theihna a awm bawk. Sterilization technique dik tak leh uluk taka enkawl hian natna kai lo turin a pui thei a, mahse hriat chian a la hlauhawm hle.
Ruh a dam loh chuan nonunion emaw malunion emaw a thlen thei. Hei hi plate dah dik loh emaw, plate-in stability a pek tlem emaw a nih chuan a thleng thei a ni.
Plate nghet taka hman theihna tur screw te chu a lo chhuak emaw, a lo inthlak emaw chuan natna, inflammation, leh nerve tihchhiatna te pawh a thlen thei a ni.
Straight reconstruction locking plate hi orthopedic surgery-ah chuan hmanraw hlu tak a ni a, stability leh support a pe a ni
discomfort tih tlem leh motion a tihbuai lai. A locking screw, low-profile design, contoured shape, leh multiple screw holes te hian fracture fixation, osteotomy, leh arthrodesis procedures atan versatile leh effective plate a ni. Mahse, surgical procedure zawng zawng ang bawkin, hriat tur harsatna a awm thei a, chu chu infection, nonunion emaw malunion, leh screw loosening emaw migration te hi a ni.
Straight reconstruction locking plate hmanga surgery neih zawh hnua ruh dam theih nan eng chen nge a rei ang?
Surgery hnua ruh a dam theih hun chhung hi mimal leh hliam nasat dan azirin a danglam thei. A tlangpuiin ruh a dam kim theih nan kar engemaw zat atanga thla engemaw zat a ngai thei.
Ruh a dam hnuah straight reconstruction locking plate hi lakchhuah theih a ni em?
A then phei chuan ruh a dam hnuah plate chu lakchhuah theih a ni. Hei hi plate-in a tihbuai emaw, a tihbuai emaw a nih chuan tih theih a ni.
Straight reconstruction locking plate hi orthopedic surgery-a hman thin plate chi khat chauh a ni em?
Ni lo, orthopedic surgery-ah hian plate chi hrang hrang hman a ni a, chung zingah chuan compression plate, dynamic compression plate, leh locking plate te pawh a tel.
Straight reconstruction locking plate hi fracture chi hrang hrang atan hman a ni em?
Ni lo, SRLP hi a tlangpuiin kut leh ke ruh tliak tan hman a ni. Fracture chi dangte chuan plate chi hrang hrang emaw, surgery tih dan emaw an mamawh thei bawk.
Straight reconstruction locking plate hi insurance-in a huam em?
Insurance coverage hi mimal insurance plan leh surgery neih dan tur chiang tak a zirin a danglam thei. Insurance provider hnenah coverage hriat theih a tha ber.
thil siam chhuah te .