Zawhna i nei em?        +86- 18112515727 ah zawhfiah theih a ni       hla@orthopaedic-china.com ah hian a awm a
Please Choose Your Language
Hetah hian i awm: In » Thil siam chhuah te » Locking plate » Ruh them lian » Proximal Lateral Tibial Locking plate -II

loading a ni

Share to:
facebook ah in share theih a ni
twitter hmanga share theih a ni
line insem theihna button a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
whatsapp share theihna tur a ni
sharethih hi share theih a ni

A hnaih ber Lateral Tibial Locking plate -II

  • 5100-26 thleng a ni

  • CZMEDITECH

A awm theih dan:

Product Description chungchang

Proximal Lateral Tibial Locking plate hi eng nge ni ?

CZMEDITECH 3.5 mm LCP® Proximal Tibia Plate hi LCP Periarticular Plating System-a tel a ni a, hei hian Screw khâr technology chu plating technique pangngai nen a thlunzawm a ni. LCP Periarticular Plating System hian 3.5 mm LCP Condylar Plates hmangin distal femur-a complex fracture te, proximal femur-a complex fracture te chu 3.5 mm LCP Proximal Femur Plates leh 3.5 mm LCP hmangin a address thei a ni

Proximal Femur Hook Plates, leh 3.5 mm LCP Proximal Tibia Plates leh 3.5 mm LCP Medial Proximal Tibia Plates hman a nih chuan proximal tibia complex fracture te a awm bawk.


Locking compression plate (LCP) hian plate shaft-ah Combi hole a nei a, chu chuan dynamic compression unit (DCU) hole leh Screw khâr hole a thlunzawm a ni. Combi hole hian plate shaft sei zawng zawngah axial compression leh locking capability flexibility a pe a ni.

Plate-a thil awmte:

  • Anatomically contoured a ni a, proximal tibia lateral aspect hnaih ber a ni

  • Load-sharing construct siam turin tension theih a ni

  • Left leh right configuration-ah a awm a, 316L stainless steel emaw sumdawnna atana thianghlim (CP) titanium emaw a awm bawk

  • Plate shaft chhungah Combi hole 5、7、9 emaw 11 emaw neiin a awm

  • Lu atanga hla deuha round hole pahnih hian interfragmentary compression atan emaw plate position secure nan emaw 3.5 mm cortex screw leh 3.5 mm cancellous Ruh screw-te an pawm a ni

  • Angle, threaded hole, round hole pahnih atanga hla takah chuan 3.5 mm cannulated Screw khâr chu a pawm a ni. Hole angle hian he Screw khâr hi plate lu chhunga central Screw khâr nen inzawmkhawmin medial fragment a thlawp thei a ni

  • Combi holes, angled locking hole atanga hla takah chuan DCU hole leh threaded locking hole te chu inzawmkhawmin a awm a

  • Contact-a awm theihna profile


A hnaih ber Lateral Tibial Locking plate

specification hrang hrang a awm

Thil siam chhuah te REF A sawifiahna Thickness a ni Vang Dung

A hnaih ber Lateral Tibial Locking plate -II 

(3.5 Screw khâr /3.5 Cortical Screw hmang rawh)

5100-2601 ah zawh theih a ni 5 a awm L 4.2 12.5 97
5100-2602 ah zawh theih a ni 7 holes a awm L 4.2 12.5 124
5100-2603 ah zawh theih a ni 9 holes a awm L 4.2 12.5 151
5100-2604 ah zawh theih a ni 11 khur a ni L 4.2 12.5 178
5100-2605 ah zawh theih a ni 13 a awm L 4.2 12.5 205
5100-2606 ah zawh theih a ni 5 a awm R 4.2 12.5 97
5100-2607 ah zawh theih a ni 7 holes a awm R 4.2 12.5 124
5100-2608 ah zawh theih a ni 9 holes a awm R 4.2 12.5 151
5100-2609 ah zawh theih a ni 11 khur a ni R 4.2 12.5 178
5100-2610 ah zawh theih a ni 13 a awm R 4.2 12.5 205


Thlalak tak tak

3

Blog a ni

Proximal Lateral Tibial Locking plate : Indication, Surgical Technique leh Outcome te thlirletna

Proximal tibia fracture hi enkawl harsa tak a ni thei a, a bik takin comminuted emaw osteoporotic fracture emaw a nih chuan. Heng complex fracture enkawlna atana hmanraw tangkai tak niin proximal lateral tibial Locking plate (PLTLP) hman hi a lo chhuak ta a ni. He thuziak ah hian PLTLP hmanna nena inzawm indication, surgical technique leh outcome te kan sawi dawn a ni.

Indication te chu

PLTLP hi proximal tibia ruh tliak enkawlna atan hman a ni ber a, chutah chuan tibial plateau, medial leh lateral condyles, leh proximal shaft te pawh a tel a ni. A bik takin fracture, traditional method hmanga stabilize harsa, intramedullary nail emaw External Fixators emaw tan a tangkai hle. PLTLP hi proximal tibia nonunion emaw malunion emaw a awm chuan hman theih a ni bawk.

Surgery hman dan tur

PLTLP hi a tlangpuiin khup ruh (knee joint) lam hawia lateral approach hmanga dah a ni. Surgeon chuan khup lateral aspect chungah incision a siam ang a, chutah chuan fracture site chu a pholang ang. Chumi hnuah chuan fracture fragment te chu tihtlem a ni a, Kirschner wire hmangin a hmunah hun eng emaw chen an fix leh thin. A dawtah chuan PLTLP chu proximal tibia nena inmil turin contoured a ni a, Screw khârte hmangin a hmunah fixed a ni. Screw khârte hian ruh nena inzawmna neiin stability a pe a, rotational emaw angular motion emaw a veng bawk.

A chhuahna tur

Zirna hrang hrangah PLTLP hman hian union rates sang tak leh clinical outcome tha tak a thlen tih hmuhchhuah a ni. Zirna pakhatah chuan thla 24 chhunga enkawl zui zelnaah union rate 98% leh mean Knee Society Score 82 a awm tih a tarlang. Zirna dang pakhatah chuan thla 48 chhunga enkawl zui zelnaah union rate 97% leh mean Knee Society Score 88 a awm tih a tarlang bawk. Mahse, hriat tur chu mimal outcome chu damlo leh fracture characteristic bik a zirin a danglam thei a ni.

Harsatna awm thei te

PLTLP hman avanga harsatna awm thei chu infection, nonunion, malunion, leh hardware failure te a ni. Damlo uluk taka thlan leh surgical technique hi harsatna awm thei tih tlem nan a pawimawh hle. Surgeon chuan a chhehvel soft tissue, peroneal nerve emaw lateral collateral ligament emaw tihchhiat loh nan a fimkhur tur a ni bawk.

Tawpna

Proximal lateral tibial Locking plate hi proximal tibia-a complex fracture enkawlna atana hmanraw tangkai tak a ni. Stability a pe a, mobilization hmasa ber a siamsak a, hei hian clinical outcome tha zawk a thlen thei a ni. Harsatna a awm theih laiin, damlo uluk taka thlan leh surgical technique hian a hlauhawmna a ti tlem thei hle. A pum puiin PLTLP hi orthopedic surgeon-te armamentarium-a proximal tibia fracture enkawlna atana thil hlu tak a ni.

FAQs te

  1. Proximal lateral tibial Locking plate hi proximal tibia fracture enkawlna kawng dang nen engtin nge a khaikhin? PLTLP hi proximal tibia-a complex fracture enkawlna atana hmanraw tangkai tak a ni tih hmuhchhuah a ni a, a bik takin traditional method hmanga stabilize harsa tak takte enkawlna atan hmanraw tangkai tak a ni. Mahse, mimal outcome chu damlo bik leh fracture characteristics a zirin a danglam thei.

  2. Proximal lateral tibial Locking plate hman hian eng nge a thatna? PLTLP hian fracture fragment-te chu stable fixation a pe a, mobilization hmasa ber a siamsak a, hei hian clinical outcome tha zawk a thlen thei a ni. A bik takin complex fracture, traditional method hmanga stabilize harsa tak tan a tangkai hle.

  3. Proximal lateral tibial Locking plate hman avanga harsatna awm thei te chu engte nge ni? PLTLP hman avanga harsatna awm thei te chu infection,nonunion, malunion, leh hardware failure te a ni. Damlo uluk taka thlan leh surgical technique hian harsatna awm thei tur a ti tlem thei hle.

  4. Proximal lateral tibial Locking plate hi a dam theih nan eng chen nge a duh? PLTLP dam hun chhung hi damlo pakhat zel leh a ruh tliak dan azirin a inang lo. Mahse, zirchianna hrang hrangah chuan PLTLP hmanna nen hian union rate sang tak a awm tih hmuhchhuah a ni.

  5. Fracture a dam hnuah proximal lateral tibial Locking plate hi lakchhuah theih a ni em? Ni e, PLTLP hi a ruh tliak a dam hnuah lakchhuah theih a ni a, chu chuan harsatna emaw thil dang emaw a thlen a nih chuan. Mahse, hardware lakchhuah chungchanga thutlukna chu case-by-case basis-a siam tur a ni a, damlo surgeon nen inrawnkhawmin siam tur a ni.


Hma chiah: 
Dawtchiah: 

CZMEDITECH A anpui che

Fracture hrang hrang tan kan solution range kimchang zawng rawh.
 
* Spine categroies lian zawng zawng khuh vek tur ;
* Quality leh delivery time lamah customer te thlamuan fo thin ;
* High cost performance kan zawm a,dealer ten profit space an neih theih nan.
Min rawn biak theih reng e

I CZMEDITECH Orthopaedic Expert te zawt rawh

I orthopaedic mamawhna atana i mamawh quality leh value, a hun taka leh budget chhunga pe turin pitfalls pumpelh turin kan pui che a ni.
Changzhou-a Meditech Technology Co., Ltd. chuan a rawn ti a.
Thil siam chhuah te
Thawhna
OEM/ODM
Tunah hian zawt rawh
© COPYRIGHT 2026 CHANGZHOU MEDITECH TECHNOLOGY CO., LTD., a hnuaia mi ang hian a hlawhtling hle. DIKNA ENGKIM A NI.