Kwisibhedlele sikarhulumente saseTamaulipas, eMexico, indoda eneminyaka engama-55 ubudala yaphuka entloko ngenxa yokuwa ngempazamo. Utyando lwenziwe ngempumelelo nguDkt Luis Rodriguez usebenzisa i-CZMEDITECH ye-Multi-lock ye-Humeral Intramedullary Nail System, ukuphumeza ukuzinza okugqwesileyo kokulungiswa kunye nokubuyisela ngokukhawuleza emva kokuhlinzwa.
I-imaging yangaphambi kokuhlinzwa ibonakalise ukuphuka kwentloko ye-humeral esusiweyo ngokungahambi kakuhle. Emva kovavanyo olubanzi, uGqr. Rodriguez ucwangcise ukulungiswa kwe-intramedullary encinci usebenzisa i-CZMEDITECH's Multi-lock Humeral Nail ukubuyisela ubume be-anatomical yejoyinti kunye nokukhuthaza ukubuyisela kwangethuba.
Indlela encinci yokuhlasela yasetyenziswa ukufikelela kwindawo yokuphuka. I-Multi-lock ye-Humeral Intramedullary Nail yafakwa phantsi kwesikhokelo se-fluoroscopic, ilandelwa zizikrufu ezininzi zokutshixa ukufikelela kwi-fixation eyomeleleyo ye-three-dimensional. I-Intraoperative imaging iqinisekise ukulungelelaniswa okugqwesileyo kunye nokuzinza kokufakelwa.

Ukhathalelo lwasemva kokutyalwa kunye nokuBuyisa
I-X-rays yasemva kokusebenza ibonise ukulungelelaniswa okufanelekileyo kunye nokulungiswa okuqinileyo. Isigulana saqala ukunyakaza kwamagxa ngosuku lwe-3 kwaye saqala ukuvuselela okusebenzayo kwiiveki ezimbini kamva. Kulandelelwano lweeveki ezintandathu, ukusebenza kwamagxa kuye kwachacha ngaphezulu kwama-80%, kungakhange kukhululwe okanye kubonwe usulelo.
I-Multi-lock ye-Humeral Intramedullary Nail 8.0 × 220 mm
Multi-lock Screw 4.5 × 34 mm
Ngaphakathi ukuLocking Screw 3.5 × 40 mm
Ukutshixa iScrew 3.5 × 40 mm
Zonke izixhobo zanikezelwa ngu I-CZMEDITECH , eyenzelwe ukuhlanganisana okulula, Isethi yesixhobo ihambelana ngokupheleleyo nazo zonke iinkqubo ze-CZMEDITECH ze-humeral nail, ezivumela ukuguqulwa okugudileyo phakathi kwentloko ye-humeral, i-shaft, kunye neenkqubo zokuphuka kwe-proximal. Ikwaxhasa ulungelelwaniso lwasekhohlo nasekunene, lula ulawulo lwempahla kwizibhedlele.

UGqr. Rodriguez uvakalise ukoneliseka okuphezulu ngokuzinza kokufakelwa kunye nokuphatha ngokulula. Ugxininise ukuba inkqubo ye-CZMEDITECH yanciphisa ixesha lokusebenza ngelixa iqinisekisa amandla okulungiswa okuqinileyo kunye nokubuyiselwa kwe-anatomical ngokuchanekileyo.
Eli tyala liqaqambisa ukusebenza kakuhle kwe I-Multi-lock ye-Multi-lock ye-Humeral Nail System ye-CZMEDITECH yonyango lwe-fractures yentloko ye-humeral. Uyilo lwayo lwe-anatomical kunye ne-multi-directional locking inikezela ukulungiswa okugqwesileyo kwaye yenza ukuba ukuvuselelwa kwangethuba, kubonisa ukuba sisisombululo esithembekileyo kwi-orthopedic trauma surgery.
Eli tyala libonisa ukuthembeka kwe Ufakelo lwe-CZMEDITECH lwe-orthopedic yotyando lokwenzakala lwamazwe ngamazwe.
I-CZMEDITECH i-Multi-lock ye-Humeral Intramedullary Nail System, eyenzelwe ukulungiswa kwe-fracture ye-humeral.
Kwisibhedlele sikaRhulumente saseTamaulipas, eMexico.
Intshukumo yePassive yaqala ngomhla we-3, kwaye ukubuyiswa ngokupheleleyo kwafunyanwa kwiiveki ze-6.
Ukutshixwa ngeendlela ezininzi kunika uzinzo oluphezulu kunye nokuxhasa ukubuyisela kwangethuba..
Ingxubevange ye-Titanium yamandla agqwesileyo kunye ne-biocompatibility.
Ewe, iqinisekisa ukulungiswa okuthembekileyo nakwi-osteoporotic bone.
Inciphisa ukuphazamiseka kwezicubu ezithambileyo kwaye inika uzinzo olungcono lwe-axial.
ISO 13485 kunye nesatifikethi se-CE somgangatho kunye nokhuseleko.
Uninzi luphinda lufumane umsebenzi wemihla ngemihla kwiiveki ezi-6-8 emva kotyando.
Ewe, ifanelekile kwi-proximal kunye ne-shaft humeral fractures ngokunjalo.