4100-02
CZMEDITECH
Intsimbi engatyiwayo / iTitanium
CE/ISO:9001/ISO13485
| Ubukho: | |
|---|---|
Ingcaciso yeMveliso
(I-S-Clavicle Plate eyenziwe yi-CZMEDITECH yonyango lweefractures ingasetyenziselwa ukuphatha i-midshaft kunye ne-distal clavicle fractures.
Olu luhlu lwe-orthopedic implants lugqithise isatifikethi se-ISO 13485, sifanelekile kuphawu lwe-CE kunye neentlobo ezahlukeneyo zenkcazo ezilungele ukulungiswa kwe-trauma kunye nokwakhiwa kwakhona kwe-clavicle shaft phakathi kunye ne-distal bone fractures. Zilula ukusebenza, zikhululekile kwaye zizinzile ngexesha lokusetyenziswa.
Ngemathiriyeli entsha ye-Czmeditech kunye nokuphuculwa kweteknoloji yokuvelisa, ukufakelwa kwethu kwamathambo kuneempawu ezikhethekileyo. Ikhaphukhaphu kwaye yomelele ngokubambelela okuphezulu. Ngaphezu koko, akunakwenzeka ukuba uqalise ukusabela kwe-aleji.
Ngolwazi oluthe vetshe malunga neemveliso zethu, nceda uqhagamshelane nathi ngokukhawuleza kwakho.
Iimpawu kunye neeNzuzo

Inkcazo
| Igama | REF(intsimbi engatyiwayo) | REF(titanium) | Inkcazo |
Ipleyiti ye-S-clavicle ephakathi |
S4100-0101 | T4100-0101 | 8 imingxuma L |
| S4100-0102 | T4100-0102 | 8 imingxunya R | |
Ipleyiti yeDistal S-clavicle |
S4100-0201 | T4100-0201 | 4 imingxuma L |
| S4100-0202 | T4100-0202 | 6 imingxuma L | |
| S4100-0203 | T4100-0203 | 8 imingxuma L | |
| S4100-0204 | T4100-0204 | 10 imingxuma L | |
| S4100-0205 | T4100-0205 | 4 imingxuma R | |
| S4100-0206 | T4100-0206 | 6 imingxuma R | |
| S4100-0207 | T4100-0207 | 8 imingxunya R | |
| S4100-0208 | T4100-0208 | 10 imingxuma R | |
I-Distal S-clavicle plate-I |
S4100-0301 | T4100-0301 | 4 imingxuma L |
| S4100-0302 | T4100-0302 | 6 imingxuma L | |
| S4100-0303 | T4100-0303 | 8 imingxuma L | |
| S4100-0304 | T4100-0304 | 10 imingxuma L | |
| S4100-0305 | T4100-0305 | 4 imingxuma R | |
| S4100-0306 | T4100-0306 | 6 imingxuma R | |
| S4100-0307 | T4100-0307 | 8 imingxunya R | |
| S4100-0308 | T4100-0308 | 10 imingxuma R | |
Owona Mfanekiso

Umxholo weNzululwazi odumileyo
I-clavicle, eyaziwa ngokuba yi-collarbone, ithambo elide elidibanisa i-scapula (i-shoulder blade) kwi-sternum (ithambo lesifuba). Idlala indima ebalulekileyo ekuhambeni kwamagxa kunye nokuzinza. Ukwaphuka kweClavicle kukwenzakala okuqhelekileyo, kubalelwa malunga ne-5% yazo zonke iifractures zabantu abadala. Kwiminyaka yakutshanje, kukho inkqubela phambili ebalulekileyo kubuchule botyando kunye nokufakelwa kokunyanga i-clavicle fractures. Ufakelo olunye olunjalo yi-S-Clavicle Plate kunye ne-Screw System.
I-S-Clavicle Plate kunye ne-Screw System yinkqubo ekhethekileyo yamathambo esetyenziselwa ukulungiswa kwe-midshaft clavicle fractures. Inkqubo iqulethe iprofayili ephantsi, i-anatomically contoured plate eyenzelwe ukulungelelanisa imilo ye-clavicle. Ipleyiti yenziwe nge-titanium alloy, eyomeleleyo, ehlala ixesha elide, kunye ne-biocompatible. Inkqubo iquka isethi yezikrufu, ezisetyenziselwa ukukhusela iplate kwithambo.
I-S-Clavicle Plate kunye ne-Screw System isetyenziswe kwiinkqubo zotyando kunyango lwe-midshaft clavicle fractures. Inkqubo ibandakanya ukwenza i-incision encinci phezu kwendawo yokuphuka, ukuveza ithambo, kunye nokulungelelanisa amaqhekeza. Ipleyiti ke idityaniswe kwimilo ye-clavicle kwaye ikhuselwe kwithambo ngokusebenzisa izikrufu. Ipleyiti kunye nezikrufu zisebenza kunye ukuzinzisa ukuphuka kunye nokukhuthaza ukuphilisa.
I-S-Clavicle Plate kunye ne-Screw System inikezela ngeenzuzo ezininzi kwiindlela eziqhelekileyo zokulungiswa kwe-clavicle fracture. Ezinye zezi zibonelelo ziquka:
Iprofayili ephantsi: I-S-Clavicle Plate kunye ne-Screw System yenzelwe ukuba ibe yiprofayili ephantsi, oku kuthetha ukuba akunakwenzeka ukucaphukisa ulusu kunye nezicubu ezithambileyo.
I-anatomically contoured: Ipleyiti i-anatomically contoured ukuze ilingane imilo ye-clavicle, enika ukulungiswa okukhuselekileyo kunye nokunciphisa umngcipheko wokungaphumeleli kokufakelwa.
I-Biocompatible: Ipleyiti kunye nezikrufu zenziwe nge-titanium alloy, eyomeleleyo, ehlala ixesha elide, kunye ne-biocompatible. Oku kuthetha ukuba akunakwenzeka ukuba kubangele ukusabela okanye ukwaliwa ngumzimba.
I-invasive kancinane: Inkqubo yotyando ye-S-Clavicle Plate kunye ne-Screw System i-invasive kancinane, oku kuthetha ukuba kubandakanya ukutshatyalaliswa okuncinci kunye nomonakalo omncinci wezicubu. Oku kunokukhokelela kumaxesha okuphilisa ngokukhawuleza kunye nokunciphisa intlungu.
Njengazo zonke iinkqubo zotyando kunye nokufakelwa, kukho imingcipheko kunye neengxaki ezinokubakho ezinxulumene ne-S-Clavicle Plate kunye ne-Screw System. Eminye yale mingcipheko ibandakanya:
Usulelo
Ukusilela kofakelo
Ukulimala kwemithambo-luvo
Ukulimala komthambo wegazi
Umanyano olungelulo umanyano okanye ulibazisekile umanyano lokwaphuka
Ukucaphukisa i-Hardware
I-S-Clavicle Plate kunye ne-Screw System yinkqubo ekhethekileyo yamathambo esetyenziselwa ukulungiswa kwe-midshaft clavicle fractures. Ibonelela ngeenzuzo ezininzi kwiindlela zemveli zokulungiswa kwe-clavicle fracture, kubandakanywa iprofayili ephantsi, uyilo lwe-anatomically contoured, i-biocompatibility, kunye nenkqubo yokuhlinzwa encinci. Nangona kunjalo, njengazo zonke iinkqubo zotyando kunye nokufakelwa, kukho imingcipheko kunye neengxaki ezinokuthi zixoxwe kunye nogqirha wakho wamathambo.