4100-02 ah a awm
CZMEDITECH a ni
Stainless Steel / Titanium hmanga siam a ni
CE/ISO:9001/ISO13485 a ni
| A awm theih dan: | |
|---|---|
Product Description chungchang
(CZMEDITECH siam S-Clavicle Plate hi midshaft leh distal clavicle fracture enkawlna atan hman theih a ni.
He series of orthopedic implant hian ISO 13485 certification a paltlang tawh a, CE mark leh specification hrang hrang nei thei a ni a, chungte chu trauma repair leh clavicle shaft middle leh distal bone fracture siamthatna atan a tha hle. Hman a awlsam a, hman laiin a nuam a, a nghet bawk.
Czmeditech thil thar leh thil siamna technology tihchangtlun tak hmang hian kan orthopedic implants te hian thil danglam bik an nei a ni. A rit zawk a, a chak zawk a, tenacity sang tak a nei bawk. Plus, allergic reaction a tichhuak tlem zawk bawk.
Kan thil siam chungchang chipchiar zawka hriat duh chuan i duh angin min rawn biak theih reng e.
Features & Hlawkna te

A sawifiahna
| Hming | REF(stainless steel) hmanga siam a ni. | REF(titanium) a ni. | A sawifiahna |
A laiah S-clavicle plate a awm |
S4100-0101 ah a awm bawk | T4100-0101 a ni | 8 holes a awm L |
| S4100-0102 ah a awm bawk | T4100-0102 a ni | 8 holes a awm R | |
Distal S-clavicle plate chu a awm a |
S4100-0201 ah hian a awm | T4100-0201 ah a awm | 4 holes a awm L |
| S4100-0202 ah a awm bawk | T4100-0202 ah hian a awm | 6 holes a awm L | |
| S4100-0203 ah a awm bawk | T4100-0203 ah a awm | 8 holes a awm L | |
| S4100-0204 ah a awm bawk | T4100-0204 ah a awm bawk | 10 a awm L | |
| S4100-0205 ah a awm bawk | T4100-0205 ah a awm | 4 a awm R | |
| S4100-0206 hmanga tih theih a ni | T4100-0206 a ni | 6 a awm R | |
| S4100-0207 ah a awm bawk | T4100-0207 ah a awm bawk | 8 holes a awm R | |
| S4100-0208 ah a awm bawk | T4100-0208 ah hian a awm | 10 a awm R | |
Distal S-clavicle plate-I atanga chhuak a ni |
S4100-0301 ah a awm bawk | T4100-0301 ah a awm | 4 holes a awm L |
| S4100-0302 ah a awm bawk | T4100-0302 ah a awm | 6 holes a awm L | |
| S4100-0303 ah a awm bawk | T4100-0303 ah a awm | 8 holes a awm L | |
| S4100-0304 ah a awm bawk | T4100-0304 ah a awm | 10 a awm L | |
| S4100-0305 ah a awm bawk | T4100-0305 ah a awm | 4 a awm R | |
| S4100-0306 ah a awm bawk | T4100-0306 ah a awm | 6 a awm R | |
| S4100-0307 ah a awm bawk | T4100-0307 ah a awm | 8 holes a awm R | |
| S4100-0308 ah a awm bawk | T4100-0308 ah a awm | 10 a awm R | |
Thlalak tak tak

Science lama thupui lar tak tak
Clavicle, collarbone tia hriat bawk hi ruh sei tak a ni a, scapula (shoulder blade) leh sternum (breastbone) a thlunzawm a ni. Shoulder movement leh stability-ah hmun pawimawh tak a chang a ni. Clavicle fracture hi hliam awm fo a ni a, puitling fracture zawng zawng zinga 5% vel a ni. Tun hnaiah chuan clavicle fracture enkawlna atana surgical technique leh implant-ah hmasawnna nasa tak a awm a. Chutiang implant pakhat chu S-Clavicle Plate leh Screw System a ni.
S-Clavicle Plate and Screw System hi orthopedic implant bik a ni a, midshaft clavicle fracture fixation atan hman a ni. He system hi low-profile, anatomically contoured plate a ni a, chu chu clavicle pianzia nena inmil tura siam a ni. Plate hi titanium alloy hmanga siam a ni a, a chak a, a chhe thei lo a, biocompatible a ni. He system hian screw set a keng tel bawk a, chu chu plate chu ruh-ah nghet taka dah nan hman a ni.
S-Clavicle Plate and Screw System hi midshaft clavicle fracture enkawlna atana surgical procedure-ah hman a ni. Chutianga tih danah chuan ruh tliakna hmun chungah incision te tak te siam a, ruh chu pholan a, ruh tliak te chu align-a siam a ni. Chumi hnuah plate chu clavicle lem angin contour-in screw hmangin ruh-ah an nghet a ni. Plate leh screw te hian an thawk dun a, fracture chu a stabilize a, damna a tichak bawk.
S-Clavicle Plate and Screw System hian clavicle fracture fixation hmanlai aiin hlawkna engemaw zat a pe a ni. Chung hlawkna thenkhat chu:
Low profile: S-Clavicle Plate and Screw System hi low profile tura duan a ni a, hei hian vun leh soft tissue te a ti na lo tihna a ni.
Anatomically contoured: Plate hi clavicle pianzia nena inmil turin anatomically contoured a ni a, hei hian fixation him zawk a pe a, implant failure hlauhawmna a ti tlem bawk.
Biocompatible: Plate leh screw te hi titanium alloy a siam a ni a, a chak a, a chhe thei lo a, biocompatible a ni. Chumi awmzia chu taksain allergic reaction emaw rejection emaw a thlen tlem zawk tihna a ni.
Minimally invasive: S-Clavicle Plate leh Screw System atana surgical procedure hi minimally invasive a ni a, chu chu incision tenau zawk leh tissue chhiatna tlem zawk a ni tihna a ni. Hei hian dam hun a tikhawtlai thei a, natna pawh a tiziaawm thei bawk.
Surgical procedure leh implant zawng zawng ang bawkin S-Clavicle Plate leh Screw System nena inzawm hian hlauhawmna leh harsatna awm thei a awm a ni. Chung hlauhawmna thenkhat chu:
Kaichhawng
Implant a hlawhchham
Nerve hliam a awm
Thisen kalna kawng hliam
Fracture chu non-union emaw delayed union emaw a ni
Hardware a ti na hle
S-Clavicle Plate and Screw System hi orthopedic implant bik a ni a, midshaft clavicle fracture fixation atan hman a ni. Clavicle fracture fixation hmanlai method aiin hlawkna engemaw zat a pe a, chung zingah chuan low profile, anatomically contoured design, biocompatibility, leh minimally invasive surgical procedure te pawh a tel. Mahse, surgical procedure leh implant zawng zawng ang bawkin, i orthopaedic surgeon nen sawiho tur hlauhawm leh harsatna awm thei a awm.
Thil siam chhuah te