Ngaba unayo nayiphi na imibuzo?        + 86- 18112515727        ingoma@orthopedic-china.com
Please Choose Your Language
Ulapha: Ekhaya » Iindaba » 6.0mm Umnqonqo Vs 5.5mm Pedicle Screw: Isikhokelo esiBanzi soGqirha kunye nabasasazo

6.0mm Vs 5.5mm Pedicle Screw: IsiKhokelo esiBanzi seeGqirha kunye nabasasazo

Iimboniselo: 0     uMbhali: Ixesha lokupapasha likaJerry: 2026-07-13 Imvelaphi: Isiza

iqhosha lokwabelana nge-facebook
iqhosha lokwabelana nge-twitter
iqhosha lokwabelana ngomgca
iqhosha lokwabelana nge-wechat
iqhosha lokwabelana ngekhonkco
iqhosha lokwabelana ngepinterest
Yabelana ngeli qhosha lokwabelana

Intshayelelo: Ukhetho olubalulekileyo lwe-Screw Diameter kwi-Spinal Fixation

Kwiminyaka engaphezu kweshumi, ingxoxo phakathi kokusebenzisa i-5.5mm kunye ne-6.0mm ye-pedicle screw systems ibe yisihloko esisembindini wotyando lomqolo. Ukhetho luchaphazela yonke into ukusuka kuzinzo lwe-biomechanical ukuya kubuchule botyando kunye neziphumo zesigulane. Koogqirha botyando, imalunga nokufikelela kulungiso olufanelekileyo. Kubathengisi kunye neengcaphephe zokuthengwa kwempahla, kubandakanya ukuhamba kwimarike entsonkothileyo ukufumana umboneleli othembekileyo, oqinisekisiweyo onikezela ngolungelelwaniso oluchanekileyo lomgangatho, ukusungula izinto ezintsha, kunye nexabiso.

Ngehlabathi jikelele imarike yokulungisa izikrufu zepedicle ekucingelwa ukuba iza kufikelela kwi-US$ 1.6 yebhiliyoni ngo-2031, ukuqonda ezi nkqubo kubaluleke kakhulu kunangaphambili. I-CZMEDITECH , kunye neminyaka eyi-14 yobuchwephesha kunye nehlabathi jikelele kumazwe angama-70 +, ibonelela ngeengcinga ezifunekayo ukuze ukwazi kakuhle olu khetho.

Yintoni equkwa sesi Sikhokelo

Esi sikhokelo siyilelwe ukukhonza zombini oogqirha botyando kunye neengcali zokuthenga. Siza kuhlolisisa:

  • Idatha yeMarike: Iintsingiselo zangoku kunye noqikelelo lokukhula kwemarike yokulungisa izikrufu ze-pedicle.

  • Ukusebenza kwe-Biomechanical: Uhlalutyo lwesakhono sokubamba intonga kunye nefuthe lezinto zentonga.

  • Isikhokelo sokuthengwa kweempahla: Imiba ephambili yeklinikhi kunye nekhonkco lokunikezela ekufuneka liqwalaselwe xa ukhetha inkqubo.

  • Uthelekiso loMboneleli: Iikhrayitheriya ezibalulekileyo zokukhetha umenzi womgangatho ophezulu, kugxilwe kuyo Isindululo sexabiso se-CZMEDITECH .

Ukuqonda izinto eziSiseko: 5.5mm kunye ne-6.0mm Pedicle Screw Systems

Ukwenza isigqibo esinolwazi, kubalulekile ukuqonda ukuba '5.5mm' kunye '6.0mm' zichaza ubukhulu becala i-tulip ye-pedicle screw yenzelwe ukwamkela. Lo mahluko ubonakala umncinci we-0.5mm uneziphumo ezibalulekileyo zeklinikhi kunye nenkqubo.

Inkqubo ye-5.5mm: Umgangatho weGolide?

I Inkqubo ye-5.5mm ithathwa ngokubanzi njengehashe lomsebenzi wokulungiswa komgogodla. Ukuthandwa kwayo kubangelwa kukuguquguquka kwayo kunye nerekhodi yekliniki. Ifanelekile kuninzi lweenkqubo zomgogodla, kubandakanywa i-lumbar kunye ne-thoracic fusions kwiimeko eziphazamisayo. Inkqubo encinci yeprofayili inokuba negalelo ekunciphiseni ukucaphuka kwezicubu ezithambileyo kwezinye izigulana. Inika oogqirha botyando iqonga eliqhelekileyo, elithembekileyo kuluhlu olubanzi lwezalathiso.

Inkqubo ye-6.0mm: Ityala lokuNyusa koBungqongqo

I Isistim ye-6.0mm idla ngokuba lolona khetho lukhethwayo xa kufuneka ubuninzi bobulukhuni bokwakha. Oku kubaluleke ngakumbi kwi:

  • Ukulungiswa kokukhubazeka: Ukulungiswa kwe-Scoliosis kunye ne-kyphosis kufuna amandla anamandla, kwaye intonga eqinile inika amandla afunekayo ukuze kugcinwe ukulungiswa.

  • I-Osteoporotic Bone: Kwizigulana ezinomgangatho ophantsi wamathambo, ukuqina okongeziweyo kunokunceda ukukhulula ujongano lwe-screw-bone, okunokunciphisa umngcipheko wokukhulula isikrufu.

  • Ulwakhiwo olude: Udibaniso oluthatha amanqanaba amaninzi luzuza ngokunyuka kozinzo olunikezwa ngentonga ye-6.0mm.

Amacandelo abalulekileyo: I-Screw Tulip kunye ne-Rod Compatibility

Owona mahluko ubalulekileyo kukuhambelana. Inkqubo ye -5.5mm (kubandakanywa ne-tulips yayo ye-screw) yenzelwe ukwamkela intonga ye-5.5mm kuphela. Inkqubo ye -6.0mm yenzelwe intonga ye-6.0mm.

I-innovation ebalulekileyo yi -screw ye-dual-diameter (DD) , ebonisa i-tulip ekwazi ukwamkela zombini ii-rods ze-5.5mm kunye ne-6.0mm. Uphononongo lwe-Biomechanical lubonise ukuba i-5.5mm intonga ngaphakathi kwe-screw ye-diameter ephindwe kabini inamandla okubamba afanayo okanye angcono kunakwinkqubo ye-diameter enye.

I Imarike yokufakelwa kwamathambo iyaguquguquka kwaye iyakhula. Ukuqonda amandla emalike asisiseko kubalulekile ekwenzeni izigqibo zobuchule bokuthenga. Imakethi yehlabathi ye-spinal implants implants ikhula ngokuzinzileyo, ikhuthazwa yinkqubela phambili yetekhnoloji kunye nabemi abalupheleyo.

IGlobal Pedicle Screw Fixation Market Outlook (2024-2031)

Imarike yehlabathi yokulungisa izikrufu ze-pedicle inkulu kwaye ikulungele ukukhula okubalulekileyo. Ngo-2024, imakethi yaqikelelwa malunga ne- US988 yezigidi∗∗yandisprojectedtoreachkufutshane∗∗US988 million kwaye yaqikelelwa malunga ne- 1.61 yezigidigidi ngo-2031 , ibonisa ireyithi yokukhula ehlanganisiweyo ye- 7.3% ngonyaka (CAGR) . Le ndlela yokukhula yomelele igxininisa imfuno engaguqukiyo neyandayo kwezi zibalulekileyo ukufakelwa komqolo.

IMetric yeMarike

Ixabiso

2024 Ixabiso leMarike

US$988 yezigidi

2031 Ixabiso leMarike eliqikelelweyo

US$ 1.61 billion

Umyinge woHlumo loNyaka (CAGR)

7.3%

Abaqhubi beMakethi abaPhambili: Ukuguga kwabemi kunye neNtuthuko yoTyando

Izinto ezininzi eziqhubela ukwanda kwemarike:

  1. Ukuguga kweGlobal Population: Ukwanda kweziganeko ze-osteoporosis, isifo se-disc degenerative, kunye ne-spinal fractures kubantu abadala ngumqhubi oyintloko.

  2. Ukunyuka kweMiqulu yoCando: Inani elikhulayo leenkqubo ze-spinal fusion zenziwa kwihlabathi jikelele ukulungisa ezi meko.

  3. Ukuqhubela phambili kwezobuGcisa: Ukwenziwa kwezinto ezintsha kuyilo lwesikrufu (umzekelo, iintloko ze-polyaxial, iintambo ezine-lead ezimbini) kunye nemathiriyeli (umz., i-titanium alloys, i-cobalt-chromium) iphucula iziphumo zeklinikhi kunye nokwandisa inani lezigulane ezinokulungiseka.

Ulwazi lweMarike yeNgingqi: I-US, iYurophu, kunye ne-Asia-Pacific

Ngelixa iNyakatho Melika kunye neYurophu zihlala zizimakethi ezinkulu ngenxa yeziseko zononophelo lwezempilo ezisekwe kakuhle, ummandla waseAsia-Pacific uvela njengendawo yokukhula okuphezulu. Izinto ziquka ukuphucula ukufikelela kukhathalelo lwempilo, ukunyuka kwemivuzo enokulahlwa, kunye nezigulana ezininzi kumazwe afana neTshayina neIndiya. Kubavelisi, ukuba nobukho behlabathi kunye nobuchule bokulawula ngundoqo ekwenzeni imali kula mathuba engingqi.

Ukusebenza kwe-Biomechanical: 6.0mm vs 5.5mm Systems

Iipropathi ze-biomechanical zenkqubo zinempembelelo ngokuthe ngqo ekusebenzeni kwayo kwezonyango. Ezimbini zezona metrics zibalulekileyo kukukwazi ukubamba intonga kunye nokumelana nokudinwa. Uphando lubonelela ngolwazi oluxabisekileyo malunga nendlela i-5.5mm kunye ne-6.0mm iinkqubo ezithelekisa ngayo.

I-Rod Gripping Capacity: Ulwazi oluvela kwi-Biomechanical Studies

Uphononongo lwe-biomechanical luka-2020 olupapashwe kwi- Spine Deformity luvavanye ukuba ingaba intonga eyi-5.5mm kwi-screw system ye-double-diameter screw (ekwaziyo ukwamkela i-6.0mm rods) isengozini. Iziphumo eziphambili ziquka:

  • Akukho buthathaka: Uphononongo lugqibe kwelokuba i-5.5-mm iintonga ngaphakathi kwezikrufu zeDD 'azikho buthathaka kune-5.5-mm iintonga kwiinkqubo ze-SD ze-axial gripping capacity (AGC) kunye ne-torsional gripping capacity (TGC)'

  • Ukwahluka koMboneleli: Uphononongo lufumanise ukuba umboneleli wentonga wayengoyena uxela kwangaphambili umthamo omkhulu wokubamba, oku kuthetha ukuba umgangatho wentonga kunye nokuveliswa kubaluleke kakhulu.

IParameter yeBiomechanical

5.5mm Inkqubo

6.0mm Inkqubo

Inkqubo ye-Dual-Diameter

Intonga yokubamba amandla

Umgangatho

Phezulu

Ifana nomgangatho (kunye ne-5.5mm intonga)

Yakha Ukuqina

Umgangatho

Yandisiwe

Ubhetyebhetye

Ukudinwa Ukumelana

Kulungile

Ngcono

Kulungile

Izicelo zeklinikhi

I-Degenerative, i-Trauma

Ukukhubazeka, I-Osteoporosis, Ukwakhiwa Okude

Zininzi izinto zombini

Imiba yezinto zentonga: Titanium vs. Cobalt-Chromium

Ukukhethwa kwezinto zentonga kubaluleke njengobubanzi bayo.

  1. I-Titanium Alloy (TiAl): Inika ukuqina okukhulu. Oku kunokuba luncedo ekuququzeleleni ulungiso kwaye kunokubonelela ngemeko yokulayisha encomekayo yokuphiliswa kwamathambo.

  2. I-Cobalt-Chromium (CoCr): Iqinile kwaye yomelele. Oku kubangela amandla okulungisa anamandla kwaye kunokubonelela ngolungiso olungcono kwindiza ye-coronal, njengoko kucetyiswa ngophando lwe-2022 apho i-5.5mm CoCr rods inikezela ukulungiswa okungcono kwe-coronal kune-6mm TiAl rods kwi-adolescent idiopathic scoliosis. Iinduku ze-CoCr zikwabonakaliswe ukuba zinamandla okubamba ngamandla.

Izinto eziphathekayo

Ukuqina

Ukolula

Eyona Isicelo seKlinikhi

Ingxubevange yeTitanium (TiAl)

Phakathi

Phezulu

Ukulungiswa kokukhubazeka (i-sagittal plane), ukuphilisa amathambo

I-Cobalt-Chromium (CoCr)

Phezulu

Phantsi

Ukulungiswa kokukhubazeka (inqwelomoya ye-coronal), ubulukhuni obukhulu

Iziphumo zeklinikhi: Ukulungiswa kokukhubazeka kunye nokumelana nokukhathala

Ukukhethwa kobubanzi bentonga kunye nezinto eziphathekayo zihambelana nemeko yeklinikhi. Umzekelo:

  • I-Scoliosis: Injongo kukuphumeza ulungiso oluphezulu lwe-3D. Ugqirha unokukhetha i-5.5mm ye-CoCr intonga yokuqina kwayo kunye nokulungiswa okuphezulu kwe-coronal okanye intonga ye-TiAl eyi-6.0mm ngenxa ye-elasticity yayo kunye nokukwazi ukuphucula iphrofayili ye-sagittal.

  • I-Trauma kunye ne-Degenerative Disease: Ukulinganisela kwamandla kunye nokumelana nokukhathala kubalulekile ukugcina uzinzo kuze kube yilapho ukudibanisa kwenzeka. Inkqubo ye-5.5mm idla ngokwaneleyo, kodwa inkqubo ye-6.0mm inokukhethwa kwizigulane ezinkulu okanye iifractures ezinzima.

Isikhokelo sokuThengwa kweeMpahla: Ungayikhetha njani iNkqubo eLungileyo

Kubasasazi kunye nezibhedlele, isigqibo sidlulela ngaphaya kweemethrikhi zeklinikhi. Ibandakanya uvavanyo olupheleleyo lweemfuno zeklinikhi, ukusebenza kakuhle kwekhonkco lokubonelela, kunye nokuthembeka komthengisi.

Imiba yeklinikhi: I-Anatomy yesigulane kunye noMgangatho weBone

  • Umgangatho Wamathambo: Kwizigulana ze-osteoporotic, ugqirha wotyando unokuthanda inkqubo eyi-6.0mm ngokungqongqo kwayo ukunciphisa uxinzelelo kujongano lwe-screw-bone.

  • I-Pedicle Morphology: Ubungakanani be-pedicle ngokwayo bumisela ubukhulu be-screw diameter enokubekwa ngokukhuselekileyo. I-diameter yentonga (5.5mm vs. 6.0mm) ayithethi ukuba i-screw diameter, kodwa inkqubo kufuneka ihambelane.

Imiba yoTyando: Uhlobo lokukhubazeka kunye noKwakha ukuNxila

  • I-Simple vs Complex Fusions: I-fusion elula yezinga elilodwa inokusebenza kakuhle nge-5.5mm system. Izakhiwo ezide zokulungiswa kokukhubazeka zihlala zixhamla kwi-rigidity eyongezelelweyo ye-6.0mm rod.

  • Ubuchwephesha bokuNciphisa: Ezinye iisistim ze-6.0mm zinezikrufu zokunciphisa ezomeleleyo eziyilelwe uguqulelo olunamandla kunye nokuguqula indlela.

Izinto eziNikezela ngeKhonkco: Iindleko ze-Inventory and Supplier Relibility

  • Ulawulo lwe-Inventory: Ukugcina zombini i-5.5mm kunye ne-6.0mm inkqubo kunokuba yindleko. Inkqubo ye-double-diameter eyamkela zombini iintonga inokunciphisa ubunzima be-inventory.

  • Ukuthembeka koMboneleli: Irekhodi eqinisekisiweyo yokuhanjiswa kwexesha, umgangatho ongaguqukiyo, kunye nenkxaso yolawulo ayinakuxoxwa. Khangela abavelisi abane-ISO 13485 kunye nezatifikethi ze-CE.

Umba

Ukuqwalasela

Umgangatho Wamathambo

6.0mm kwithambo le-osteoporotic; 5.5mm kwithambo eliqhelekileyo

Ubungakanani bePedicle

Khetha i-screw diameter esekelwe kwi-pedicle morphology; inkqubo kufuneka ihambelane

Yakha Ubude

6.0mm kulwakhiwo olude; 5.5mm kwizakhiwo ezimfutshane/eziphakathi

I-Inventory Strategy

Inkqubo ye-Dual-diameter inciphisa ubunzima be-SKU

Uthelekiso loMboneleli: Yintoni omawuyijonge kumvelisi

Ukukhetha iqabane elifanelekileyo lemveliso sisigqibo esicwangcisiweyo esichaphazela ngokuthe ngqo ukukwazi kwakho ukukhuphisana kwimarike. Ayingabo bonke ababoneleli bokufakelwa kwamathambo abalinganayo.

Iziqinisekiso zoMgangatho: CE, ISO 13485, kunye ne-FDA

Iimfuno ezingaxoxisiyo kuye nawuphi na umenzi obalulekileyo.

  • ISO 13485: Umgangatho wehlabathi wolawulo lomgangatho kwizixhobo zonyango.

  • Ukumakishwa kwe-CE: Ibonisa ukuthotyelwa kwempilo yaseYurophu, ukhuseleko, kunye nemigangatho yokukhuselwa kwendalo, imfuneko yokuthengisa eYurophu.

  • Ukubhaliswa kwe-FDA: Kufunwa ukuthengiswa eUnited States.

Iimveliso ze-CZMEDITECH , umzekelo, zi-CE-certified kwaye ziyahambelana nomyalelo we-European device medical device.

Ubunakho bokuVelisa: Ukuchaneka, isikali, kunye nokwenza ngokwezifiso

  • Imveliso yangaphakathi: Umvelisi onezityalo zakhe kunye nezixhobo eziphambili ze-CNC zibonelela ngolawulo olukhulu kumgangatho, amaxesha okukhokela, kunye neendleko.

  • Ukwenziwa ngokwezifiso: Ukukwazi ukunikezela Izisombululo ze -OEM/ODM ziluncedo olukhulu kubahambisi abajonge ukusungula iimveliso zabo ezinegama. I-CZMEDITECH ibonelela Izisombululo zesiko kwaye inikezela nge-co-branding kumaqabane.

Ukufikelelwa kwiGlobal: uLungiselelo kunye neNkxaso yoLawulo

  • Ukuhanjiswa ngokukhawuleza: Inethiwekhi ethembekileyo yokuthumela kumazwe ngamazwe (i-DHL, i-FedEx, njl.) ibalulekile.

  • Inkxaso yoLawulo: Ababoneleli abanokubonelela ngamaxwebhu kwaye bancedise ngobhaliso lolawulo lwengingqi banokuba ngamaqabane axabisekileyo. I-CZMEDITECH , kunye neminyaka eyi-14 + yamava kunye nabathengi be-2,500 + kumazwe angama-70 +, ingumzekelo wobu buchule behlabathi.

Kutheni i-CZMEDITECH Igqamile kuBasasazi

I-CZMEDITECH ingaphezulu kunomthengisi; liqabane lobuchule bokukhula. Ngepotfoliyo ebanzi yeemveliso ezivunyiweyo ze-900+ CE, sinikezela:

  • Umgangatho oqinisekisiweyo: Iimveliso zethu zivavanywa ngokungqongqo ngoomatshini, ukudinwa, kunye novavanyo lwezonyango, oluxhaswa yi-CE, ISO 13485, ISO 9001 izatifikethi.

  • Izisombululo eziSebenzayo ngeendleko: Ngokusebenzisa ikhonkco lokubonelela ngamathambo aseTshayina aqolileyo, sinikezela nge-30% + yokonga iindleko ngaphandle kokubeka esichengeni umgangatho.

  • Ukwenziwa ngokwezifiso kunye neBranding: Sibonelela ngeenkonzo eziguquguqukayo ze-OEM/ODM, ukusuka kuyilo ukuya kwimveliso yobuninzi, okukuvumela ukuba wakhe uphawu lwakho.

  • Inkonzo yeHlabathi jikelele: Iqela lethu libonelela ngenkxaso yeelwimi ezininzi ezingama-24/7, izisombululo eziqinisekisiweyo zeeyure ezingama-72, kunye nezibanzi. uqeqesho lotyando.

Izisombululo ze-CZMEDITECH: Umgangatho Wokuvala kunye neXabiso

Nge CZMEDITECH , siyayiqonda i-nuances yesigqibo se-5.5mm vs. 6.0mm. Injongo yethu kukubonelela oogqirha botyando ngezona zixhobo zithembekileyo, eziphezulu zokusebenza kunye nabasasazi ngokukhuphisana, okuthembekileyo.

Umnikelo wethu we-5.5mm kunye ne-6.0mm Pedicle Screw

Sinikezela ngoluhlu olubanzi lweenkqubo zokulungisa umgogodla, kubandakanywa zombini i-5.5mm kunye ne-6.0mm i-polyaxial kunye ne-monoaxial pedicle screws kunye neentonga. Iimveliso zethu zenziwe kusetyenziswa izixhobo zeprimiyamu ezifana ne-Ti6Al4V ELI titanium alloy, iqinisekisa ukuhambelana kwe-biocompatibility ekhethekileyo kunye namandla oomatshini.

Product Feature

CZMEDITECH Unikezelo

Iinketho zeDiameter yentonga

5.5mm kunye ne-6.0mm

Iintlobo zeScrew

Polyaxial kunye neMonoaxial

Izinto eziphathekayo

Ti6Al4V ELI Titanium Alloy

Iziqinisekiso

CE, ISO 13485, ISO 9001

Ukwenza ngokwezifiso

OEM / ODM ekhoyo

Ubunakho be-OEM/ODM: Izisombululo zesiko kwi-Brand yakho

Siyaqonda ukuba abasasazi abaninzi kufuneka bazakhele ezabo iimpawu zophawu. Iinkonzo zethu ze-OEM/ODM zikuvumela ukuba uchaze eyakho inkqubo, ukupakishwa, kunye nophawu. Silawula yonke inkqubo, ukusuka kuyilo kunye nokuveliswa ukuya ekuthotyelweni, siqinisekisa indlela engenamthungo yokuthengisa.

Isiphelo: Ukwenza iSigqibo esinolwazi

Ukhetho phakathi kwe-6.0mm kunye ne-5.5mm ye-pedicle screw system yinto engathandekiyo, enefuthe kwisicwangciso sotyando, iziphumo zesigulane, kunye ne-logistics yezoshishino. Inkqubo ye-6.0mm inikezela ngobunzima obukhulu, obulungele ukukhubazeka kunye neemeko ezinzima. Inkqubo ye-5.5mm ihlala ingumgangatho oguquguqukayo, othembekileyo kuninzi lweenkqubo. Ngapha koko, ukuvela kwezikrufu ezimbini-diameter kunika isisombululo esiguquguqukayo esinciphisa ubunzima be-inventri ngelixa ugcina ingqibelelo ye-biomechanical.

Ngokuqonda ubungqina bekliniki, iintsingiselo zemarike, kunye nobuchule bomboneleli wakho, unokwenza isigqibo esiluncedo zombini izigulane kunye neyona nto isezantsi. I-CZMEDITECH ime ikulungele ukuba liqabane lakho kolu hambo.

Imibuzo Ebuzwa Rhoqo (FAQ)

1. Ndingasebenzisa intonga ye-5.5mm ngesikrufu esiyi-6.0mm?

Hayi, akunjalo. I-tulip ye-screw ye-6.0mm yenzelwe intonga eyi-6.0mm. Nangona kunjalo, izikrufu ezimbini ze-diameter zenzelwe ukwamkela zombini ii-5.5mm kunye ne-6.0mm rods, zinika isisombululo esiguquguqukayo.

2. Yeyiphi i-diameter yentonga eyomeleleyo?

Intonga eyi-6.0mm yomelele kwaye yomelele kunentonga eyi-5.5mm. Oku kunyuka kokuqina kunenzuzo yokulungiswa kokukhubazeka kunye nokwakhiwa okude. Nangona kunjalo, intonga ye-5.5mm yanele kwiintlobo ezininzi eziqhelekileyo.

3. Yintoni inkqubo yesikrufu se-pedicle diameter (DD)?

Inkqubo ye-DD yenzelwe i-tulip ye-screw engakwazi ukuhlalisa zombini i-5.5mm kunye ne-6.0mm rods, inikezela ukuguquguquka okukhulu kunye nokunciphisa iimfuno ze-inventory.

4. Yintoni intonga eyona nto ilungileyo?

Zombini i-Titanium Alloy (TiAl) kunye neCobalt-Chromium (CoCr) zibalaseleyo. I-TiAl iyalastiki ngakumbi, ngelixa i-CoCr iqinile. Olona khetho lufanelekileyo luxhomekeke kukhetho logqirha kunye nenjongo yeklinikhi.

5. Ngaba intonga eyi-5.5mm kwisikrufu seDD ibuthathaka?

Hayi. Uphononongo lwe-Biomechanical lubonisa ukuba i-5.5-mm iintonga kwi-DD screws azikho buthathaka kunenkqubo ye-diameter eyodwa ye-axial kunye ne-torsional gripping capacity.

6. Ithini imilinganiselo yemarike yehlabathi yezikrufu ze-pedicle?

Imarike yehlabathi yokulungisa izikrufu ze-pedicle yaqikelelwa kwi- US988million ngo-2024∗∗andisexpectedtogrowto∗∗US988 million ngo-2024∗∗ andiseexpectedtogrowto ∗∗ US 1.61 billion ngo-2031.

7. Ndikhetha njani phakathi kwenkqubo ye-5.5mm kunye ne-6.0mm?

Ukhetho luxhomekeke kutyando oluthile. I-6.0mm isoloko ikhethwa ngenxa yobunzima obukhulu kwizigulane ezinokukhubazeka okanye i-osteoporotic, ngelixa i-5.5mm ingumgangatho oguquguqukayo kwiimeko ezininzi.

8. Zeziphi iziqinisekiso ekufuneka umthengisi we-pedicle screw ephezulu abe nazo?

Jonga i-ISO 13485, i-CE Marking, kunye nobhaliso olufanelekileyo lwe-FDA, oluyimfuneko kuqinisekiso lomgangatho kunye nokufikelela kwimarike yehlabathi.

9. Ngaba i-CZMEDITECH ibonelela nge-custom-branded OEM/ODM iinketho?

Ewe, I-CZMEDITECH ngumvelisi wekhontrakthi okhokelayo onikezela ngemveliso ye-OEM/ODM eguquguqukayo kubanikezeli abajonge ukwenza ezabo izifakelo ezinegama.

10. I-CZMEDITECH ingalinceda njani ishishini lam lokuhambisa?

Sinikezela ngofakelo oluqinisekisiweyo, olukumgangatho ophezulu, amaxabiso akhuphisanayo, inkxaso yolawulo, ukubhengeza uphawu, kunye nokuhanjiswa kwehlabathi okukhawulezayo, konke kuxhaswe ngaphezu kweminyaka eyi-14 yobuchwephesha kunye nenkxaso ye-24/7.

Qhagamshelana nathi

Qhagamshelana neengcaphephe zakho ze-CZMEDITECH ze-Orthopedic

Sikunceda ukuba uphephe imigibe yokuhambisa umgangatho kwaye uxabise imfuno yakho ye-orthopedic, ngexesha kunye ne-budget.
Changzhou Meditech Technology Co., Ltd.

Inkonzo

Buza Ngoku
© COPYRIGHT 2023 CHANGZHOU MEDITECH TECHNOLOGY CO., LTD. ONKE AMALUNGELO AGCINIWE.