HAYI.
|
I-REF
|
Inkcazo
|
Qty.
|
|
1
|
4200-0701
|
Ubunzulu beGauge(0-120mm)
|
1
|
|
2
|
4200-0702
|
Ucingo olunemisonto lwesikhokelo 2.5mm
|
1
|
|
3
|
4200-0703
|
Ucingo olunemisonto lwesikhokelo 2.5mm
|
1
|
|
4
|
4200-0704
|
I-Cannulated Drill Bit eneBhloko encinci 4.5mm
|
1
|
|
5
|
4200-0705
|
I-Cannulated Countersink Φ9
|
2
|
|
6
|
4200-0706
|
Isitshixo seHex
|
2
|
|
7
|
4200-0707
|
Isitshixo seSikhokelo socingo esiLungisayo esiParallel
|
1
|
|
8
|
4200-0708
|
IsiKhokelo esineeNcingo ezininzi
|
1
|
|
9
|
4200-0709
|
Thepha i-Cannulated Screw 6.5mm
|
1
|
|
10
|
4200-0710
|
Screwdriver Hexagonal 3.5mm
|
1
|
|
11
|
4200-0711
|
Ukucoca i-Stylet 2.5mm
|
1
|
|
12
|
4200-0712
|
I-Sleeve ye-Drill
|
1
|
|
13
|
4200-0713
|
IsiKhokelo socingo esinoLungisa oluDityaniswayo
|
1
|
|
14
|
4200-0714
|
I-Cannulated Screwdriver Hexagonal 3.5mm
|
1
|
|
15
|
4200-0715
|
Ibhokisi yeAluminiyam
|
1
|
|
16
|
4200-0516
|
DHS / DCS Isitshixo, Umkhono weGolide
|
1
|
|
17
|
4200-0517
|
Screwdriver Hexagonal 3.5mm
|
1
|
|
18
|
4200-0518
|
DCS Angle Guide 95 Degree
|
1
|
|
19
|
4200-0519
|
DHS Angle Guier 135 degree
|
1
|
|
20
|
4200-0520
|
I-DHS Reamer
|
1
|
|
21
|
4200-0521
|
I-DCS Reamer
|
1
|
|
22
|
4200-0522
|
Ibhokisi yeAluminiyam
|
1
|
Owona Mfanekiso

Ibhlog
I-6.5mm yesixhobo se-screw esifakwe kwi-cannulated sisixhobo sotyando esisetyenziselwa utyando lwamathambo ukuzinzisa ukuphuka kwamathambo. Ezi zikrufu zinomqolo kwaye ziyilelwe ukuvumela ukuba ucingo lwesikhokelo lufakwe ethanjeni phambi kokuba isikrufu sibekwe, ngaloo ndlela kuncitshiswe umonakalo wezicubu ezithambileyo ngexesha lotyando. Kweli nqaku, siza kuphonononga i-anatomy, usetyenziso, kunye nobuchule bokusebenzisa i-6.5mm eseti yesixhobo se-cannulated screw.
Iseti yesixhobo se-screw se-6.5mm esikhonkxiweyo siquka isikrufu, intambo yesikhokhelo, intwana ye-drill e-cannulated, kunye nomqheba. Isikrufu senziwe ngentsimbi engatyiwayo kwaye sithungelwe ukusivumela ukuba sibambe ithambo ngokuqinileyo. Intambo yesikhokelo isetyenziselwa ukufaka i-screw kwithambo kwaye ibekwe kuqala, ilandelwa yi-screw. I-drill bitana esetyenzisiweyo isetyenziselwa ukudala umngxuma wokulingwa kwintambo yesikhokelo kunye nesikrufu, kwaye isiphatho sisetyenziselwa ukuphatha izixhobo ngexesha lotyando.
I-6.5mm yesixhobo se-screw esifakwe kwi-cannulated sisetyenziswa ngokuqhelekileyo kunyango lweefractures kumathambo amade, njenge-femur kunye ne-tibia. Ezi zikrufu ziluncedo ngakumbi kwiifractures ezingazinzanga kwaye zifuna ukulungiswa ukuthintela ukufuduka. Uyilo lwe-cannulated lwe-screws luvumela umonakalo omncinci omncinci wezicubu ezithambileyo ngexesha lokufakwa, ezinokunceda ukukhuthaza ukuphilisa ngokukhawuleza kunye nokunciphisa umngcipheko weengxaki.
Ukongeza ekunyangeni iifractures, i-6.5mm yesixhobo se-screw esifakwe kwi-cannulated sinokusetyenziswa kunyango lwe-osteotomies (ukusikwa kwethambo ngotyando) kunye ne-arthrodesis (ukudibanisa amathambo amabini).
Ngaphambi kokusebenzisa i-6.5mm yesixhobo se-screw se-cannulated, kubalulekile ukuvavanya ngokufanelekileyo isigulane kunye nokulimala kwabo ukuqinisekisa ukuba olu hlobo lokulungiswa lufanelekile. Ubuchwephesha botyando bokusebenzisa isixhobo se-6.5mm esiqholiweyo sesixhobo sokutshiza bubandakanya la manyathelo alandelayo:
Lungiselela isigulane utyando kwaye ulawule i-anesthesia.
Yenza isiko kwindawo yokwaphuka okanye i-osteotomy.
Sebenzisa ubuchule bokucinga njenge-X-rays okanye i-fluoroscopy ukukhokela ukufakwa kocingo lwesikhokelo kwithambo.
Sebenzisa i-drill bit enkonkxiweyo ukwenza umngxuma wokulingwa wocingo lwesikhokelo kunye nesikrufu.
Faka ucingo lwesikhokelo kwithambo kwaye uqinisekise ukubekwa kwayo usebenzisa iindlela zokucinga.
Faka isikrufu phezu kocingo lwesikhokelo kwaye uluqinise de lukhuseleke.
Vala ukusika kwaye ufake isamente okanye esinye isixhobo sokuthintela njengoko kufuneka.
Kubalulekile ukuba uqaphele ukuba ukusetyenziswa kwe-6.5mm yesixhobo se-screw esifakwe kwi-cannulated kufuna uqeqesho olufanelekileyo kunye namava ukuphepha iingxaki ezifana nokubekwa kwe-screw engafanelekanga okanye umonakalo kwizicubu ezijikelezileyo.
I-6.5mm yesixhobo se-screw esifakwe kwi-cannulated sineenzuzo ezininzi ngaphezu kwezinye iintlobo zezixhobo zokulungisa. Ezi ziquka:
Umonakalo omncinci wezicubu ezithambileyo ngexesha lokufakwa
Ukuzinza okuphezulu kunye namandla okulungisa
Amaxesha okuphilisa ngokukhawuleza ngenxa yomonakalo omncinci wezicubu ezithambileyo
Umngcipheko omncinci weengxaki ezinxulumene nokufakelwa
Nangona kunjalo, kukwakho nezinye izinto ezingeloncedo ekusebenziseni isixhobo sesixhobo se-screw se-6.5mm, kubandakanya:
Okunokwenzeka kumonakalo kwizicubu ezijikelezileyo ngexesha lokufakwa
Ubunzima bokubekwa kwesikrufu kwiindawo ezithile ze-anatomical
Okunokwenzeka kokungaphumeleli kokufakelwa kwiintlobo ezithile zokwaphuka