Views: 0 Author: Site Editor A chhuah hun: 2025-10-09 A bul tanna: Hmun
Clinical Case Report: Khup zawng zawng (Total Knee Arthroplasty) tih a ni
Implant design hmasawn tak, surgical preci ion, leh damlo outstan sding outcome te a ni
Total Knee Arthroplasty (TKA) hi khup ruh natna nasa tak, deformity, emaw, chak lohna emaw enkawlna atana standard surgical procedure a ni. Khawvel pumah advanced orthopedic implants mamawhna a san chhoh zel avangin CZMEDITECH chuan khawvel puma orthopaedic surgeon-te tan high-precision, durable, leh biocompatible solution a pe chhunzawm zel a ni. He case study hian Mexico rama Nuevo León-a CZMEDITECH MMR Knee System hmanga khup zawng zawng thlak danglamna hlawhtling tak a sawi a ni.
Mipa damlo kum 49 mi, ROCHA SUSANA DEL CARMEN chuan a khup dinglam a hrehawm lo tih a lantir a, thla ruk kalta chhung khan kea kal laiin natna nasa tak a nei bawk. Enfiahnaah chuan khup dinglam ruh chu a deformity tih hmuhchhuah a ni a, movement laiin audible popping a awm a, joint capsule-ah edema a lang chiang hle a, hun rei tak chhung squat emaw ding thei lo emaw a ni tih a chiang bawk.
Operation hmaa X-ray - Hma lam atanga thlir
Enfiahnaah khup deformity a awm tih hmuhchhuah a ni
He surgery hi Hospital Zambrano Hellion ah hmangin hlawhtling takin an ti a ni CZMEDITECH MMR Knee Joint System . Preoperative planning chuan alignment leh balance tha ber a siam thei a ni. CZMEDITECH-in a design ergonomic surgical instrument set hian precision tha tak a pe a, hnathawh dan a ti awlsam a, intraoperative time pawh a ti tlem bawk. Intraoperative leh postoperative imaging hmangin implant positioning dik tak leh functional joint restoration a awm tih a chiang hle.
Surgical Approach leh Exposure dan tur
Ruh buatsaih dan leh Implant dah dan
CZMEDITECH Surgery hmanrua hman mek
CZMEDITECH surgical instrument system hian outcome mumal tak neih theihna turin coordination dik tak leh simplified operation a pe a, surgical time a tihtlem bakah accuracy a ti sang bawk.
CZMEDITECH MMR Khup System Component hrang hrangte
CZMEDITECH MMR Knee System hian design element thar tak tak a keng tel a, chu chuan surgical outcome leh damlo satisfaction a tichak a ni:
Oblique osteotomy: hmalam condyle tan 5° leh hnunglam condyle tan 1°
Gradient hmanga inthlak danglamna curve design
Cobalt-chromium-molybdenum hmanga siam tibial tray-ah hian a awm a
Surgical instrument system inzawmkhawm a ni
bone mass humhalh nan leh anterior notch risk tihziaawmna turin anterior condyle tan 5° leh posterior condyle tan 1° a ni.
Traditional walking curve a thlak a, femoral-tibial contact area a tipung a, wear a ti tlem a, joint balance a tichiang bawk.
Tibial tray chu cobalt-chromium-molybdenum (Co-Cr-Mo) alloy polished sang tak hmanga siam niin hun rei tak a daih theih nan leh insert installation awlsam tak a ni.
Procedure hun tlem zawka surgical outcome mumal tak neih theihna turin coordination dik tak leh simplified operation.
Heng features te hian CZMEDITECH Knee System hi total knee arthroplasty-a precision, rintlak leh hun rei tak chhunga performance tum surgeon te tan chuan solution duh ber a ni.
Damlo hian a dam tha hle a, joint stability leh range of motion a ti tha zawk bawk. Rehabilitation hmasa berah chuan alignment dik tak, natna tihziaawmna nasa tak, leh functional restoration a awm tih hmuhchhuah a ni. Follow-up-ah chuan implant fixation nghet tak leh hun rei tak chhunga satisfaction a awm tih hmuhchhuah a ni.
Postoperative X-ray - Hma lam atanga thlir
Postoperative X-ray - A sir lam atanga thlir
Patient hian mobility score-ah 90% zetin hmasawnna a nei a, thla 6 chhunga enkawlnaah natna tihziaawmnaah 95% satisfaction a nei tih a sawi bawk.
He case hian a hlawhtlinna a tichak a ni CZMEDITECH MMR Knee System hman a ni. Tunlai ruh lam enkawlnaah A design hi khawvel pum huapa minimally invasive leh precision-driven joint reconstruction lama hmasawnna nen a inmil a, postoperative complications tihziaawmna leh damlo satisfaction tihchangtlun a ni. CZMEDITECH hian CE leh ISO13485 standard hmanga certified orthopaedic implant leh instrument siamna kawngah a inpe reng a ni.
CZMEDITECH hi orthopedic implant siamtu lar tak a ni a, kum 10 chuang zet a thawk tawh a, spine, trauma, joint, leh sports medicine systems lama tui tak a ni. Kan thil siamte hi ram 50 chuangah thawnchhuah a ni a, khawvel hmun hrang hranga damdawi in, distributor, leh surgeon-te chuan an precision, stability leh a man tlawm avangin an ring tlat a ni.
Total Knee Arthroplasty hi surgical procedure a ni a, khup ruh chhe tawhte chu artificial component hmanga thlak a, natna tihziaawmna leh mobility siam that leh a ni.
He system hian hun rei tak chhunga hnathawh theihna turin cobalt-chromium-molybdenum alloy tibial tray, high-strength femoral components leh wear-resistant polyethylene insert te a hmang a ni.
Anatomical precision, load distribution tha tak, wear tihtlem, leh optimized instrument system hmanga surgical handling awlsam tak an pe a ni.
Thil siam chhuah te