Zawhna i nei em?        +86- 18112515727 ah      zawhfiah theih a ni  hla@orthopaedic-china.com ah hian a awm a
Please Choose Your Language
You are here: In » Chanchinthar » Locking plate resources te pawh a awm » Case Study:S-Clavicle Locking Plate hmanga Clavicle Fracture enkawlna hlawhtling tak neih a ni

Case Study:S-Clavicle Locking Plate hmanga Clavicle Fracture enkawlna hlawhtling tak neih a ni

Views: 0     Author: Site Editor A chhuah hun: 2025-11-06 A chhuahna: Hmun

facebook ah in share theih a ni
twitter hmanga share theih a ni
line insem theihna button a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
sharethih hi share theih a ni

Case Study: Mexico—S-Clavicle Locking Plate hmanga Clavicle Fracture Enkawlna Hlawhtling



Inhmelhriattirna

He case study-ah hian Mexico rama State Hospital-a clavicle fracture enkawlna hlawhtling tak tih kan zirchiang a ni. Dr. Pedro-a expert team-in surgery an neihah hian specialized S-clavicle locking plate hman a ni a, hei hian tunlai orthopaedic implant hmanga complex fracture enkawlna atana hman tangkai dan a pholang a ni. He thuziak hian damlo zinkawng, surgery tih dan leh a dam leh dan chipchiar takin a tarlang a ni.

Case chungchang tlangpui

Damlo hi hmeichhia kum 34 mi a ni a, Allman Type 1-a classified right clavicle fracture a nei a, midshaft fracture a ni tihna a ni. Hetiang hliam hi enkawl dik loh chuan harsatna a thlen fo thin. Damlo dinhmun a enfiah hnu leh a imaging result a enfiah hnuah Dr. Pedro chuan S-clavicle locking plate hmanga open reduction and internal fixation (ORIF) tih a rawt a.

operation hmaa-clavicle-xray-mexico-case-czmeditech

Surgery tih dan tur

Surgery-ah hian specialized S-clavicle locking plate hman a ni a, hei hi implant hmasawn tak, multi-fragmented fracture-a stability pe thei tura siam a ni. Hole 8 nei plate hi a fitting dik tak leh a dam laia a ruh tliak chu a thlawp theih avangin thlan a ni. Operation chu a kal tluang hle a, an tih lai hian harsatna a awm lo.

clavicle-surgery-orif-procedure-mexico-czmeditech hmanga tihdam theih a ni

Postoperative Care leh Recovery chungchang

Damlo hi operation a nih aṭanga darkar 24 chauh a liam hnuah chhuahtir a ni a, hei hian enkawlna kalphung a ṭhatzia a tilang chiang hle. Surgery hnu kar ruk chhunga imaging lakah chuan a ruh chu a dam vek tawh tih hmuhchhuah a ni a, damlo hian nitin hnathawhna chu hrehawmna awm lovin a thawk leh thei ta a ni. Hetianga dam chakna hian orthopaedic surgery-a S-clavicle locking plate ang chi implant hmanlai hman a thatzia a tilang chiang hle.

operation hnua-clavicle-locking-plate-fixation-czmeditech

Implant chungchang sawifiahna

Implant Type : S-clavicle khar theihna plate 

Size : 8-hole, dinglam sir 

Material : Titanium alloy hmanga siam a ni a, a chakna leh a chhe thei lo 

Hman dan : Clavicle fracture stabilize na atana siam a ni


s-clavicle-locking-plate-8hole-dinglam-czmeditech

Instrument Set a ni

Instrument zawng zawng hi a supply vek a ni CZMEDITECH , assembly awlsam tak, precision alignment, leh surgical time tihtlem nan siam a ni. An ergonomic design hian intraoperative handling a ti tha a, workflow mumal tak a siam bawk.

clavicle-locking-plate-instrument-set-czmeditech-ah chuan a chhuak leh ta a ni

Clinical Outcome atanga lo chhuak

He case hian clavicle fracture ang maia complex fracture enkawl hunah implant dik thlan leh surgical team tawnhriat ngah tak neih a pawimawhzia a tilang chiang hle. S-clavicle locking plate chu duhthlanna ṭha tak a ni tih a chiang a, a ruh tliak chu a nghet thei a, a dam chak zawk bawk. Dr. Pedro leh a team-te hlawhtlinna hian ruh lam enkawlna lama tunlai thiamna hmanga damlote hlawhtlinna a tihchangtlun zel dan a tarlang a ni.

He case hian rintlakzia a tilang chiang hle CZMEDITECH orthopaedic implants hman a ni. International trauma surgery atana hman tur

FAQ

1. Damlo hian eng ang clavicle fracture nge a neih?

Kum 34 mi hmeichhe damlo hian Allman Type I midshaft fracture a nei a, a fragment tam tak a awm bawk.

2. Engvangin nge conservative treatment ai chuan surgery hi thlan a nih?

Fracture hi multi-fragmented leh displaced nature a nih avangin conservative fixation hian alignment a nei thei lo va, chuvangin ORIF chu thlan a ni.

3. Eng surgical technique nge hman a nih?

Open reduction leh internal fixation (ORIF) chu fracture tawp te pholan a, locking plate hmanga secure-in an ti a.

4. Engvangin nge S-clavicle locking plate hi thlan a nih?

S-shaped contour hi clavicle anatomy nen a inmil a, stress chu a sem darh vek a, implant loosening emaw migration emaw a veng bawk.

5. Intraoperative complication a awm em?

Procedure chu a smooth a, nerve, vascular, soft-tissue complication a awm lo va, dam lehna pawh a thleng lo.

6. Damlo chu operation hnuah eng chen nge chhuahtir a nih?

Damlo hi operation hnu darkar 24 chhungin hliam damna nghet tak neiin chhuahtir a ni.

7. Postoperative rehabilitation-a thil pawimawh ber berte chu engte nge ni?

A hmaa kephah zawi zawia inchei hi fuih a ni a, phurrit rit tak takte pumpelh tur a ni a, damdawi lam thurawn angin chetna tihpun zauh zauh a ngai bawk.

8. He case hi eng clinical significance nge ni?

He case hian multi-fragmented fracture-a S-clavicle locking plate-te’n stability tha tak leh damna rang tak an pek dan a tilang chiang hle.

9. S-clavicle locking plate hnathawh ber chu eng nge ni?

Midshaft emaw complex clavicle fracture emaw a stabilize a, union a tichak a, anatomical alignment a siam tha leh bawk.

10. A thuziak hian eng nge a ṭhatna?

Titanium alloy hmanga siam a ni a, a rit lo va, a chak a, biocompatible a ni a, allergic reaction a thlen theih a rinawm loh.

Min rawn biak theih reng e

I CZMEDITECH Orthopaedic Expert te zawt rawh

Quality delivery-a harsatna awmte pumpelh turin kan pui che a, i orthopaedic mamawh chu a ngai pawimawh hle a, a hun takah leh budget-ah.
Changzhou-a Meditech Technology Co., Ltd. chuan a rawn ti a.

Thawhna

Tunah hian zawt rawh
© COPYRIGHT 2023 CHANGZHOU MEDITECH TECHNOLOGY CO., LTD., a hlawhtlinna chu a hlawhtlinna a ni. DIKNA ENGKIM A NI.