5100-10 thleng a ni
CZMEDITECH a ni
| A awm theih dan: | |
|---|---|
Product Description chungchang
Distal ulna hi distal radioulnar joint-a thil pawimawh tak a ni a, hei hian forearm-a rotation pe turin a pui a ni. Distal ulnar surface hi carpus leh kut nghet taka awm theihna tur platform pawimawh tak a ni bawk. Chuvangin distal ulna-a unstable fractures hian wrist movement leh stability a tichhe vek a ni. Distal ulna lian leh te, a chunga mobile soft tissue awmte nen a inzawm chuan standard implant hman a harsa hle. 2.4 mm Distal Ulna Plate hi a bik takin distal ulna fracture-a hman tur atana siam a ni.
Anatomically contoured a ni a, distal ulna nena inmil tur a ni
Low profile design hian soft tissue irritation a tihziaawm thei
2.7 mm locking leh cortex screw pahnih a pawm a, angular stable fixation a pe bawk
Pointed hooks hian ulnar styloid tihtlem nan a pui thin
Angled locking screw hmang hian ulnar lu chu him takin a nghet thei a ni
Screw option hrang hrang hmangin fracture pattern hrang hrang chu him taka stabilise theih a ni
Sterile chauh a awm a, stainless steel leh titanium-ah a awm

| Thil siam chhuah te | REF | A sawifiahna | Thickness a ni | Vang | Dung |
| VA Distal Medial Radius Locking Plate (2.7 Locking Screw/2.7 Cortical screw hmang rawh) | 5100-1001 thleng a ni | 4 holes a awm L | 2 | 7.2 | 41 |
| 5100-1002 thleng a ni | 5 a awm L | 2 | 7.2 | 48 | |
| 5100-1003 thleng a ni | 6 holes a awm L | 2 | 7.2 | 55 | |
| 5100-1004 thleng a ni | 4 a awm R | 2 | 7.2 | 41 | |
| 5100-1005 thleng a ni | 5 a awm R | 2 | 7.2 | 48 | |
| 5100-1006 thleng a ni | 6 a awm R | 2 | 7.2 | 55 |
Thlalak tak tak

Blog a ni
Kut ruh tliak hi hliam na tak a ni a, natna nasa tak a thlen thei a, nitin hnathawh a tichhe thei bawk. Tun hma chuan heng ruh tliak te hi enkawl dan tur a tlem hle a, a tam zawkah chuan dam rei tak a ngai a, damlote chu an hnathawh theihna a hloh vek a ni. Mahse, orthopaedic technology lama hmasawnna avang hian VA Distal Medial Radius Locking Plate siam a ni a, hei hi solution thar a ni a, hei hian kut ruh tliak nei damlote tan outcome tha zawk a pe thei a ni.
Kut ruh tliak (wrist fracture) hriatchhuah leh enkawlna kawngah hian kutphah taksa (anatomy) hriatthiam hi a pawimawh hle. Wrist joint hi ruh pariat atanga siam a ni a, chung zingah chuan radius, ulna leh carpal ruh te pawh a tel. Radius hi forearm ruh pahnih zinga lian zawk a ni a, wrist ruh tliak tam ber a ni.
Tun hma chuan kut ruh tliak enkawlna kawng hrang hrangah casting, splinting, leh external fixation te a awm thin. Heng hmanrua te hi damlo thenkhat tan chuan a hlawk thei hle a, mahse dam rei tak leh an kal theihna pawh a tlem phah fo thin. Chu bâkah, ruh tliak na tak emaw, a hnuaia thil dang emaw nei damlote tân pawh an ṭha lo thei bawk.
VA Distal Medial Radius Locking Plate hi kut ruh tliak tan solution thar a ni a, traditional treatment method aiin advantage engemaw zat a nei a ni. Plate hi distal radius medial aspect-a fit turin siam a ni a, stable fixation a pe a, early range of motion a phalsak bawk. Locking mechanism hian plate migration emaw screw loosening emaw a ti tlem bawk a, hei hian operation dang neih belh a ngai lo.
Kut ruh tliak tan VA Distal Medial Radius Locking Plate hman hian thatna engemaw zat a nei a. Chung zingah chuan:
Stability leh fixation tihchangtlun
Range of motion hmasa ber
Complication awm theihna a ti tlem
Recovery hun rei zawk
Functional outcomes tihchangtlun a ni
VA Distal Medial Radius Locking Plate dahna tur surgical technique-ah hian kutphah medial aspect-ah incision te tak te a awm a. Chumi hnuah plate chu distal radius-ah dah a ni a, plate kaltlangin ruh chhungah screw dah a ni. Locking mechanism hian fixation nghet tak a siam a, incision chu suture emaw staple emaw hmangin a khar bawk.
VA Distal Medial Radius Locking Plate surgery hnua dam lehna leh rehabilitation hi a tlangpuiin traditional treatment method aiin a rang zawk. Damlote chuan operation an neih hnu lawkah range of motion exercise an tan thei a, thla engemaw zat chhungin an dam leh vek beisei theih a ni. Taksa leh hnathawh that nan taksa lam enkawlna pawh a tha thei bawk.
VA Distal Medial Radius Locking Plate hi kut ruh tliak enkawlna him leh tangkai tak a nih thu hmuhchhuah a nih laiin, harsatna awm thei thenkhat hriat tur a awm. Chung zingah chuan:
Kaichhawng
Screw a lo chhuak ta
Plate atanga inthlak danglamna
Nerve tihchhiat a ni
Regional pain syndrome buaithlak tak a ni
VA Distal Medial Radius Locking Plate hi kut ruh tliak tan solution thar a ni a, damlote tan outcome tha zawk a pe thei a ni. A stable fixation, early range of motion, leh complication awm theihna a tlem avangin traditional treatment method aiin a danglamna beisei awm tak a ni.
VA Distal Medial Radius Locking Plate surgery atanga dam leh theih nan eng chen nge a ngaih?
Damlo a zirin dam hun hi a inang lo a, mahse thla engemaw zat chhungin a dam kim theih beisei a ni.
VA Distal Medial Radius Locking Plate hmanga surgery hman dan tur chu eng nge ni?
Surgical technique-ah hian kutphah medial aspect-ah incision te tak te a awm a, chumi hnuah plate chu distal radius-ah dahin plate kaltlangin ruh chhungah screw dah a ni.
VA Distal Medial Radius Locking Plate hi kut ruh tliak enkawlna hmanlai nen engtin nge a khaikhin?
VA Distal Medial Radius Locking Plate hian hmanlai hmanraw aiin a thatna engemaw zat a nei a, chung zingah chuan stability leh fixation tihchangtlun, range of motion hmasa ber, leh complication awm theihna tihtlem te pawh a tel.
VA Distal Medial Radius Locking Plate operation hnuah physical therapy a ngai em?
Operation hnua chakna leh hnathawh tihchangtlun nan physical therapy hman a tha thei.
Thil siam chhuah te