5100-09 thleng a ni
CZMEDITECH a ni
| A awm theih dan: | |
|---|---|
Product Description chungchang
Distal ulna hi distal radioulnar joint-a thil pawimawh tak a ni a, hei hian forearm-a rotation pe turin a pui a ni. Distal ulnar surface hi carpus leh kut nghet taka awm theihna tur platform pawimawh tak a ni bawk. Chuvangin distal ulna-a unstable fractures hian wrist movement leh stability a tichhe vek a ni. Distal ulna lian leh te, a chunga mobile soft tissue awmte nen a inzawm chuan standard implant hman a harsa hle. 2.7 mm Distal Ulna Plate hi a bik takin distal ulna fracture-a hman tur atana siam a ni.
Anatomically contoured a ni a, distal ulna nena inmil tur a ni
Low profile design hian soft tissue irritation a tihziaawm thei
2.7 mm locking leh cortex screw pahnih a pawm a, angular stable fixation a pe bawk
Pointed hooks hian ulnar styloid tihtlem nan a pui thin
Angled locking screw hmang hian ulnar lu chu him takin a nghet thei a ni
Screw option hrang hrang hmangin fracture pattern hrang hrang chu him taka stabilise theih a ni
Sterile chauh a awm a, stainless steel leh titanium-ah a awm
| REF | REF | A sawifiahna | Thickness a ni | Vang | Dung |
| VA Distal Lateral Radius Locking Plate (2.7 Locking Screw/2.7 Cortical Screw hmang rawh) | 5100-0901 ah biak theih a ni | 5 a awm | 2 | 6.7 | 47 |
| 5100-0902 ah biak theih a ni | 6 a awm | 2 | 6.7 | 55 |
Thlalak tak tak

Blog a ni
Fractures of the distal radius hi hliam tlangpui a ni a, tlu emaw, infiamna lama hliam emaw, trauma avanga thleng thei a ni. Heng hliamte hian natna nasa tak a thlen thei a, a hring thei a, kutphah pawh a che thei lo thei bawk. Kut hnathawh that leh nan chuan surgical intervention a ngai mai thei. Distal radius fracture enkawlna atana solution thar ber pakhat chu VA Distal Lateral Radius Locking Plate hi a ni. He thuziak hian he enkawlna kawng thar hi a tlangpuiin a tarlang ang a, a hlawkna te, surgery hman dan te, leh a rah chhuah te pawh a tel ang.
VA Distal Lateral Radius Locking Plate hi surgical implant a ni a, distal radius fracture enkawlna atana siam a ni. Locking plate system a ni a, distal radius anatomy nena inmil tura siam bik a ni. Plate hi titanium a siam a ni a, hei hian a chhe thei lo va, biocompatible a ni. Locking plate system hi plate, screw leh locking mechanism hmanga siam a ni a, chu chuan ruh tliak chu a nghet thei a ni.
VA Distal Lateral Radius Locking Plate hian distal radius fracture enkawlna hmanlai aiin hlawkna engemaw zat a pe a ni. Locking mechanism hian ruh tliak chu stability tha tak a pe a, hei hian wrist chu a hmaa mobilizate theihna a siamsak a ni. Hei hian dam rei zawk leh overall outcome tha zawk a thlen thei a ni. Plate hian distal radius anatomy nen pawh a inmil tawk hle a, hei hian harsatna awm thei tur a ti tlem thei a, surgery dikna pawh a ti tha thei bawk.
VA Distal Lateral Radius Locking Plate atana surgical technique hi minimally invasive procedure a ni a, kutphah chungah incision te tak te siam a ngai a ni. Chumi hnuah chuan ruh tliak chu tihtlem a ni a, a nih loh leh fluoroscopic guidance hmangin a inrem leh a ni. Chumi hnuah chuan plate chu ruh chungah screw hmangin an nghet a, chu chu ruh chu a nghet theih nan locked position-ah dah a ni. Chumi hnuah chuan incision chu khar a ni a, a dam laiin kutphah ven nan cast emaw brace emaw hman theih a ni.
Zirna hrang hrangah VA Distal Lateral Radius Locking Plate hian distal radius fracture enkawlna kawngah result tha tak a nei tih hmuhchhuah a ni. Hetianga tih damlote hian an kutphah natna, range of motion leh an kutphah hnathawh zawng zawngah nasa takin hma an sawn tih an sawi. Locking plate system hian harsatna a nei tlem hle bawk a, screw loosening emaw breakage emaw a awm thei bawk.
VA Distal Lateral Radius Locking Plate lama hmasawnna avang hian technique thar leh implant thar siam chhuah a ni. Entirnan, tunah chuan plate thenkhat chu distal radius-a anatomy nena inmil, pre-contoured shape hmanga design a ni a, chu chuan surgery dikna a ti sang thei a ni. Plate dangte chu variable angle locking mechanism hmanga design a ni a, chu chuan screw dahnaah a inthlak danglam thei zawk a ni.
VA Distal Lateral Radius Locking Plate hmanga operation hnua dam lehna leh rehabilitation-ah hian a tlangpuiin physical therapy leh home exercise te hi hman a ni. Rehabilitation hian a tum ber chu kut leh kut chakna leh thawh theihna siam leh a ni. Physics therapist chuan damlo chu range of motion leh chakna siamna tichaktu exercise hmangin a kaihruai ang. Damlote chu an dam chhung hian wrist brace emaw cast emaw vuah turin an fuih thei bawk.
Surgery zawng zawng ang bawkin VA Distal Lateral Radius Locking Plate hian hlauhawmna leh harsatna awm thei engemaw zat a keng tel a ni. Chung zingah chuan infection, thisen chhuah, nerve emaw thisen kalna kawng chhiat, implant failure te pawh a tel thei. Mahse, he procedure hmanga harsatna awm zawng zawng hi a hniam a, a hlawkna chuan a hlauhawmna a tluk pha fo bawk.
VA Distal Lateral Radius Locking Plate hi eng nge ni? VA Distal Lateral Radius Locking Plate hi surgical implant a ni a, distal radius fracture enkawlna atana siam a ni. Locking plate system a ni a, distal radius anatomy nena inmil tura siam bik a ni. Plate hi titanium a siam a ni a, hei hian a chhe thei lo va, biocompatible a ni. Locking plate system hi plate, screw leh locking mechanism hmanga siam a ni a, chu chuan ruh tliak chu a nghet thei a ni.
VA Distal Lateral Radius Locking Plate hman hian eng hlawkna nge a neih? VA Distal Lateral Radius Locking Plate hian distal radius fracture enkawlna hmanlai aiin hlawkna engemaw zat a pe a ni. Locking mechanism hian ruh tliak chu stability tha tak a pe a, hei hian wrist chu a hmaa mobilizate theihna a siamsak a ni. Hei hian dam rei zawk leh overall outcome tha zawk a thlen thei a ni. Plate hian distal radius anatomy nen pawh a inmil tawk hle a, hei hian harsatna awm thei tur a ti tlem thei a, surgery dikna pawh a ti tha thei bawk.
Engtin nge VA Distal Lateral Radius Locking Plate hi dah a nih? VA Distal Lateral Radius Locking Plate atana surgical technique hi minimally invasive procedure a ni a, kutphah chungah incision te tak te siam a ngai a ni. Chumi hnuah chuan ruh tliak chu tihtlem a ni a, a nih loh leh fluoroscopic guidance hmangin a inrem leh a ni. Chumi hnuah chuan plate chu ruh chungah screw hmangin an nghet a, chu chu ruh chu a nghet theih nan locked position-ah dah a ni.
VA Distal Lateral Radius Locking Plate hman hian eng nge a chhuah? Zirna hrang hrangah VA Distal Lateral Radius Locking Plate hian distal radius fracture enkawlna kawngah result tha tak a nei tih hmuhchhuah a ni. Hetianga tih damlote hian an kutphah natna, range of motion leh an kutphah hnathawh zawng zawngah nasa takin hma an sawn tih an sawi. Locking plate system hian harsatna a nei tlem hle bawk a, screw loosening emaw breakage emaw a awm thei bawk.
VA Distal Lateral Radius Locking Plate hman hnuah recovery process hi eng ang nge ni? VA Distal Lateral Radius Locking Plate hmanga operation hnua dam lehna leh rehabilitation-ah hian a tlangpuiin physical therapy leh home exercise te hi hman a ni. Rehabilitation hian a tum ber chu kut leh kut chakna leh thawh theihna siam leh a ni. Physics therapist chuan damlo chu range of motion leh chakna siamna tichaktu exercise hmangin a kaihruai ang. Damlote chu an dam chhung hian wrist brace emaw cast emaw vuah turin an fuih thei bawk.
Thil siam chhuah te