2100-26 thleng a ni
CZMEDITECH a ni
Titanium a ni
1 SET a ni
CE, ISO 13485 a ni
FedEx, DHL, TNT, EMS, etc. te pawh a awm bawk.
OEM leh ODM a awm bawk
Return / Replacement a ni
Femoral neck fracture a awm chuan internal fixation hman a ni
Cannulated design for precise guide wire insertion
Lu nei lo compression structure chu stable fracture fixation atan
Minimally invasive implantation technique
Medical-grade material, fatigue resistance sang tak nei
| A awm theih dan: | |
|---|---|
Product Description chungchang
Titanium mesh cage hi structural spinal implant a ni a, corpectomy partial emaw complete emaw hnua vertebral body thlakna tur atana siam a ni. Solid interbody device ang lo takin mesh cage hian open cylindrical architecture a nei a, hei hian bone graft material leh a kianga vertebral endplate te direct contact a phalsak a ni.
Spinal surgery-ah chuan titanium mesh cages te hian load-bearing implant angin hna an thawk a, chu chuan anterior column integrity a siam tha leh a, chutih rualin biological fusion a thlawp bawk. Complex spinal reconstruction-a foundational implant anga ngaih an ni nasa hle a, a bik takin trauma, tumor resection, infection, emaw advanced degeneration avanga vertebral body hloh a nih chuan.
Anterior column hian spinal alignment, axial load transmission leh sagittal balance vawn thatna kawngah hmun pawimawh tak a chang a ni. He column hi tihchhiat a nih chuan reconstruction hian mechanical stability leh biological fusion te pawh a ngaihtuah tel a ngai a ni.
Titanium mesh cages hian anterior column-ah structural support a pe nghal a, chutih rualin bone grafts-te containment device atan a thawk bawk. Vertebral height siam that leh disc space a awm reng avangin cage hian load-sharing dik tak a siam thei a, posterior fixation system-a stress nasa lutuk a tihziaawm bawk.
Corpectomy hnuah surgeon-te chuan defect size mumal lo nena inmil thei, axial strength tling tak pe thei leh fusion tichak thei implant an mamawh a ni. Titanium mesh cages hian intraoperative length customization leh graft capacity lian tak hmangin heng thil mamawh te hi a phuhruk a ni.
Solid vertebral body replacement implants nena khaikhin chuan mesh cages hian biological integration nasa zawk a phal a, chutih rualin mechanical reliability a vawng reng a, hei vang hian multi-level leh high-load spinal reconstruction-ah chuan duhthlanna duh ber a ni.
Titanium mesh cage hi cervical, thoracic, leh lumbar corpectomy tih zawh hnuah hman a ni nasa hle. Heng surgery-ah hian vertebral body lakchhuah hian critical structural void a siam a, chu chu collapse leh neurological compromise ven nan siam thar leh a ngai a ni.
Cage hian spinal continuity a siam tha leh a, defect zawng zawngah controlled fusion a siam thei a, chutih rualin spinal alignment dik tak a vawng reng bawk.
High-energy spinal trauma-ah chuan vertebral body collapse hian anterior column a tichhia fo thin. Titanium mesh cages hian mechanical stabilization a pe nghal a, vertebral height siam that lehnaah a pui a, kyphotic deformity a tihziaawm bakah neurological recovery a pui bawk.
Tumor nena inzawm vertebral tihchhiat hian aggressive resection a ngai fo a, chu chu reconstruction a ngai fo thin. Titanium mesh cage hian surgeon-te chu chhiatna lian tak tak siam thar leh theihna a siam a, chutih rualin radiotherapy ang chi adjuvant therapies te pawh a awm thei bawk.
An chhe thei lo leh an insiamrem theihna hian oncologic spine surgery atan a tha hle.
Spinal infection emaw, reconstruction hmasa hlawhchham emaw a nih chuan titanium mesh cages hian biological environment chhe tawh takah fusion a thlawp rualin stability siam thatna tur solution rintlak tak a pe a ni.
Cervical application-ah chuan titanium mesh cage hmangin vertebral height leh corpectomy hnua cervical lordosis te chu siam that leh a ni. Intraoperative-a an trim dik theihna hian anatomical reconstruction dik tak a siam thei a ni.
Thoracic reconstruction hian rib cage leh thoracic spine atanga load transfer avang hian axial strength sang tak a mamawh a ni. Titanium mesh cages hian mechanical resistance tling tak a pe a, chutih rualin segment sei tak takah fusion a support bawk.
Thoracolumbar junction hi biomechanically complex tak a ni a, a inthlak danglamna hmun a ni. Titanium mesh cages hian alignment vawng reng turin a pui a, he hmun pawimawh takah hian stress concentration a tihziaawm bawk.
Lumbar reconstruction-ah chuan titanium mesh cages hian anterior column san zawng a siam tha leh a, load-bearing demand sang tak a support a, a tam zawkah chuan posterior pedicle screw system nena inzawm a ni.
Open mesh structure hian bone graft material leh a chhehvel vertebral endplate inkara surface contact a ti sang a, fusion potential leh biological stability a ti sang a ni.
Titanium mesh cages hi axial load lian tham tuar thei tura engineer a ni a, chutih rualin physiological load-sharing a awm thei a, stress shielding a tihziaawm bakah ruh remodeling a tichak bawk.
Surgeon-te chuan cage chu intraoperative-in patient-specific anatomy nena inmil turin an trim thei a, chu chuan optimal fit leh alignment restoration a siam thei a ni.
Surface friction leh endplate contact dik tak hian implant migration leh subsidence hlauhawmna a tihziaawm a, a bik takin supplemental fixation nena inzawm chuan.
Cage hi Ti-6Al-4V titanium alloy hmanga siam a ni a, a chakna leh rit ratio leh corrosion resistance a neih avangin orthopaedic implant-ah an hmang nasa hle.
Titanium biocompatibility hian inflammatory response a ti tlem a, chutih rualin spinal environment-ah hun rei tak chhung implant stability a vawng reng bawk.
Alloy hian fatigue resistance a neih hian cyclic spinal loading condition hnuaiah hun rei tak chhunga performance a thlawp a ni.
Titanium mesh cages hian postoperative imaging assessment a phalsak a, implant material denser zawk nena khaikhin chuan artifact interference a tlem zawk a ni.
Cage hi anterior plating system nen a inzawm tlat a, stability nghal a ni.
Posterior fixation hian overall construct rigidity leh load distribution a tichak a ni.
Biomechanical stability tihpun nan complex reconstruction-ah hian combined fixation strategy hi hman a ni tlangpui.
Thil siam zawng zawng hi ISO 13485-certified quality system hmanga siam a ni.
Full traceability hian consistency leh regulatory compliance a tichiang a ni.
Batch tin hian mechanical leh dimensional testing an nei vek a ni.
Product te hi international sterilization leh packaging standard zawm tura siam a ni.
CZMEDITECH hian size hrang hrang configuration leh customization option hrang hrang a pe a.
OEM leh private-label services te hian distributor branding strategy te a pui thin.
Thil siam thatna hian khawvel pum huapa thawhpui te tan supply rintlak a siamsak thin.
Global logistics theihna hian hun rei tak chhunga distributor thawhhona a pui a ni.
Vertebral body thlak danglamna leh anterior column siam tharna atan hman a ni.
Cervical, thoracic, thoracolumbar leh lumbar hmun hrang hrangah te a awm a.
Ni e, autograft emaw allograft ruh emaw a awm thei.
Ni e, posterior fixation system nen a inzawm tlangpui.
Ni e, full OEM leh customization service a awm bawk.
Product chungchang sawifiahna
|
Product Hming
|
A sawifiahna
|
|
TItanium Mesh Cage hmanga siam a ni
|
10*100mm a ni
|
|
12*100mm a ni
|
|
|
14*100mm a ni
|
|
|
16*100mm a ni
|
|
|
18*100mm a ni
|
|
|
20*100mm a ni
|
Features & Hlawkna te



Thlalak tak tak

Thil siam chhuah te