Patella Mesh Locking Plate hmanga siam a ni

  • 5100-34 thleng a ni

  • CZMEDITECH a ni

A awm theih dan:

Product Description chungchang

Features & Hlawkna te

Patellae lian leh te tan simple, wedge leh complex fracture te hmachhawn tura siam plate hrang hrang.

Plate design hian damlo mamawh bik phuhruk nan bending leh contouring a ti awlsam hle. Windows hmang hian soft tissue chu suture hmangin attach theih a ni.

Plate te hi fracture pattern bik leh damlo taksa peng hrang hrang mamawh phuhruk nan tan theih a ni.

Variable angle (VA) locking holes hian screw angulation 15 ̊ thleng a siam thei a, ruh chi hrang hrang te chu a target thei a, fracture line leh hardware dangte pawh a veng thei bawk.

Screw hole hian 2.7 mm VA locking a pawm a, cortex screw pawh a pawm bawk.

Plate keah hian interfragmentary fixation atan bicortical polar (apex to base) screw dah theih a ni.

Titanium leh Stainless Steel hmanga siam a ni.

Patella Mesh Locking Plate hmanga siam a ni

specification hrang hrang a awm

Thil siam chhuah te REF A sawifiahna Thickness a ni Vang Dung
Patella Mesh Locking Plate (2.7 Locking Screw hmang rawh) a ni. 5100-3401 ah zawh theih a ni 16 holes A te a ni 1 30 38
5100-3402 ah zawh theih a ni 16 holes a awm Medium 1 33 42
5100-3403 ah zawh theih a ni 16 holes A lian hle 1 36 46


Thlalak tak tak

Patella Mesh Locking Plate hmanga siam a ni

Blog a ni

Patella Mesh Locking Plate: I hriat tur zawng zawng

Khup hliam chungchang sawi dawn chuan patella hi hmun tam tak a ni a, chhiatna a tawk thei a ni. Patella, kneecap tia hriat lar hi ruh te tak te, khup hmalam a awm a ni. A awmna hmun leh a hnathawh avang hian hliam chi hrang hrang, a ke ruh tliak leh a inthlak danglam thei a ni. A then phei chuan patella fracture a awm chuan surgical intervention a ngai thei a, chu chu patella mesh locking plate hman a ni thei bawk. He thuziak ah hian patella mesh locking plate chungchanga hriat tur zawng zawng kan sawi dawn a, a thatna te, a hlauhawmna te, leh a recovery process te pawh kan sawi dawn a ni.

Patella Mesh Locking Plate tih hi eng nge ni?

Patella mesh locking plate hi surgical hardware chi khat a ni a, patella ruh tliak siamthatna atana hman thin a ni. Titanium hmanga siam a ni tlangpui a, a dam laiin patella chu a nghet thei ang bera siam a ni. Plate hi ruh lamah screw hmangin an nghet a, chu chuan plate chu a hmunah a lock a, ruh chu a dam tha thei a ni.

Engtikah nge Patella Mesh Locking Plate hi hman a nih?

Patella mesh locking plate hi patella fracture nasat leh displaced a nih chuan hman a ni tlangpui. Chumi awmzia chu ruh chu chi hrang hrangah a inthen a, a awmna pangngaiah a awm tawh lo tihna a ni. Hetiang hunah hian damna dik tak neih theih nan leh hun rei tak chhunga harsatna awm thei tur venna atan patella mesh locking plate hman a ngai mai thei.

Patella Mesh Locking Plate hman tangkai dan

Patella fracture enkawlna atan patella mesh locking plate hman hian hlawkna engemaw zat a nei a. Chung zingah chuan:

  • Stability tihchangtlun: Plate hian ruh chu a hmunah a vawng tlat a, chu chuan a dam tha thei a, stability a ti tha bawk.

  • Dam chak zawk: Plate hian ruh chu a nghet zawk a, dam chak zawk turin a pui a ni.

  • Harsatna awm thei tihtlem: Patella mesh locking plate hman hian harsatna awm thei, non-union (ruh a dam loh) emaw malunion (a awm dan pangngaia dam lohna) emaw a ti tlem a ni.

Risk leh Complication awm thei te

Surgery dang ang bawkin patella mesh locking plate hman hian hlauhawmna leh harsatna awm thei a awm a ni. Chûng zîngah chuan:

  • Infection: Surgery a awm apiangin natna kai theihna a awm.

  • Thisen chhuah: Operation lai emaw, operation hnuah emaw thisen a chhuak thei a, a dang pawh a ngai thei bawk.

  • Nerve emaw thisen kalna kawng emaw a chhiat: Surgery neih chhung hian nerve emaw thisen kalna kawng emaw a chhiat theihna a awm.

  • Hardware chhiat: A nghetna atana hman plate emaw screw emaw a chhiat thei a, chu chu operation dang neih belh a ngai thei bawk.

  • Natna leh nuam lo: Natna leh lungawi lohna hi operation hnuah a awm fo a, kar eng emaw zat a awm thei.

Surgery atana inbuatsaihna

I doctor chuan i patella fracture enkawlna atan patella mesh locking plate a rawt a nih chuan, operation atana inbuatsaih nan step engemaw zat i tih theih a ni. Chûng zîngah chuan:

  • Damdawi i ei tur eng pawh doctor nen sawiho.

  • Damdawi in pan leh haw tur ruahmanna siam.

  • I dam lehna tur atana i in buatsaih.

  • Hnathawh emaw thil dang emaw atanga chawlh hun ruahman.

Patella Mesh Locking Plate hman dan tur

Patella mesh locking plate siam dan tur chu a tlangpuiin a hnuaia step te hi a ni:

  • Anesthesia: General anesthesia (muthilh tir theitu) emaw regional anesthesia (taksa hnuai lam ti na thei) emaw pek i ni ang.

  • Incision: I surgeon chuan a ruh tliakna hmun chungah incision a siam ang.

  • Reduction: Ruh chi hrang hrangte chu an awmna tur dik takah an inrem leh ang.

  • Plate dah dan: Plate chu ruh lamah screw hmangin a nghet ang.

  • Closure: Incision chu stitches emaw staples emaw hmangin khar a ni ang.

  • Dressing: Incision na hmunah hian dressing emaw bandage emaw an vuah ang.

Hetiang tih dan hi a tlangpuiin darkar 1-2 vel a ngai a, ni engemaw zat damdawi ina awm a ngai thei bawk.

Recovery Process a ni

Surgery zawhah i doctor thupek chu uluk takin i zawm a ngai ang a, chu chuan damna tha tak a nei thei ang. Hei hian a huam thei ang:

  • Kar engemaw zat chhung ke natna atanga rit lak loh.

  • Kawngkhar emaw, walker emaw hmanga kal kual theih.

  • Natna damdawi a pek angin ei.

  • Range of motion leh chakna tihchangtlun nan exercise tih.

  • Physics therapy session-a tel ve thin.

Mi tam zawk chu operation an neih hnu thla 4-6 chhungin an hnathawh dan pangngaiah an kir leh thei a ni. Mahse, ruh chu a dam kim theih nan kum khat vel a la ngai thei.

Taksa lam enkawlna

Patella mesh locking plate tih zawh hnua dam lehna kawngah hian physical therapy hi a pawimawh hle. I physical therapist chuan i khup chakna leh range of motion i neih leh theih nan exercise program a duang ang. Hei hian exercise te pawh a huam thei a, chungte chu:

  • Ke dinglam a chawi sang

  • Khup tihzauh a ni

  • Quadriceps set a ni

  • Hamstring chu a curl a

  • Wall slide a awm bawk

I physical therapist pawhin natna leh hliam tihziaawmna turin ice emaw heat therapy ang chi modalities a hmang thei bawk.

Nitin Hnathawh turah kir leh ila

Patella mesh locking plate procedure zawh hnua nitin hnathawhna lama kir leh tur chuan hun engemaw chen a la ngai thei. Khup a hliam nawn loh nan doctor thupek uluk taka zawm a pawimawh. Thil tih dan pangngaia kir leh theihna tur tips thenkhat chu:

  • Hun kal zelah activity level tihsan zauh zauh.

  • I doctor-in okay a pek che hma loh chuan high-impact activities, tlan emaw, zuang emaw tih loh tur.

  • A tul angin khup brace emaw support emaw vuah.

Follow-Up Care neih a ni

Surgery zawhah i doctor nen follow-up appointment engemawzat i kal a ngai ang a, i hmasawnna enfiah a ngai ang. Heng appointment neih chhung hian i doctor chuan damna dik tak neih theih nan x-ray a la thei a, a tul angin i enkawlna tur ruahmanna chu a siamrem thei bawk.

Prognosis leh Outlook te

Mesh locking plate hmanga enkawl patella fracture prognosis hi a tlangpuiin a tha hle. Mi tam zawk chuan operation an neih hnu kum khat chhungin an khup chu an thawk tha thei vek a ni. Mahse, mi thenkhat chuan hun rei tak chhung harsatna an tawk thei a, chu chu arthritis emaw, natna emaw a ni thei.

Enkawlna dang (Alternative Treatments) te pawh a awm thei

A then phei chuan patella fracture hi operation tel lovin immobilization emaw casting emaw hmanga enkawl theih a ni. Mahse, heng hmanrua te hi fracture na tak emaw, displaced emaw tan chuan a tha lo mai thei.

Zawhna Zawh fo thin

  1. Patella mesh locking plate procedure atanga dam leh theih nan eng chen nge a mamawh?

  • Thil tih dan pangngaia kir leh tur chuan thla 4-6 vel a ngai thei a, mahse ruh chu a dam kim theih nan kum khat thleng a ngai thei.

  1. Patella mesh locking plate tih hian eng hlauhawmna nge a neih?

  • Risk te chu infection, thisen chhuah, nerve emaw thisen kalna kawng tihchhiat, hardware chhiat, leh natna te a ni thei.

  1. Patella fracture hi operation tel lovin enkawl theih a ni em?

  • A then phei chuan patella fracture hi operation tel lovin immobilization emaw casting emaw hmanga enkawl theih a ni.

  1. Patella mesh locking plate procedure hlawhtlinna rate chu engzat nge ni?

  • He procedure hlawhtlinna hi a tlangpuiin a tha a, mi tam zawk chuan operation an neih hnu kum khat chhungin an khup chu an thawk tha leh vek a ni.


Hma chiah: 
Dawtchiah: 

I CZMEDITECH Orthopaedic Expert te zawt rawh

Quality delivery-a harsatna awmte pumpelh turin kan pui che a, i orthopaedic mamawh chu a ngai pawimawh hle a, a hun takah leh budget-ah.
Changzhou-a Meditech Technology Co., Ltd. chuan a rawn ti a.

Thawhna

Tunah hian zawt rawh
© COPYRIGHT 2023 CHANGZHOU MEDITECH TECHNOLOGY CO., LTD., a hnuaia mi ang hian a hlawhtling hle. DIKNA ENGKIM A NI.