5100-29 thleng a ni
CZMEDITECH a ni
| A awm theih dan: | |
|---|---|
Product Description chungchang
3.5 mm Distal Lateral Tibial Locking Plate hi CZMEDITECH Locking Compression Plate (LCP®) System-a tel a ni a, locking screw technology leh plating technique pangngai te a inzawm khawm a ni. Heng anatomically shaped 3.5mm plate te hi stainless steel emaw titanium alloy emaw hmanga siam niin 5-13 hole configuration a awm a ni.
Distal locking screw hian articular surface chu a pui a ni
Volkmann-a triangle leh Chaput fragment te chu targeted locking a ni
Anatomically a siam a ni
Shaft holes hian 3.5 mm locking screw, 3.5 mm cortex screw leh 4.0 mm cancellous screw te a pawm a ni
Head holes hian 3.5 mm locking screw, 2.7 mm leh 3.5 mm cortex screw leh 4.0 mm cancellous screw te a pawm a ni
60o twist in shaft chu distal tibia anatomy atan contoured a ni
Submuscular insertion atan tapered tip a awm
316L stainless steel emaw titanium alloy emaw hmanga siam a ni
Shaft chhunga 60°twist chu distal tibia anatomy atan contoured a ni: plate contouring tlem zawk a ngai.
Anatomic reduction: Anatomic plate profile leh joint bula parallel screw pali chuan metaphysis chu diaphysis-ah tihtlem a pui a, chu chuan alignment leh functional anatomy a siam leh thei a ni. Intra-articular fractures tan chuan joint congruency siam that nan anatomic reduction tih ngei ngei tur a ni.
Stable fixation: Conventional leh locking screw te inzawmkhawm hian ruh density eng pawh nise fixation tha ber a pe a ni.
Thisen supply humhalh: Limited-contact plate design hian plate-to-bone contact a ti tlem a, periosteal blood supply humhalh nan a pui bawk.
3.5 mm LCP Anterolateral Distal Tibia Plate hi distal tibia-a fracture, osteotomies, leh nounionions atan hman a ni a, a bik takin osteopenic bone-ah chuan hman a ni.

| Thil siam chhuah te | REF | A sawifiahna | Thickness a ni | Vang | Dung |
A hnaih ber Lateral Tibial Locking Plate-II (3.5 Locking Screw/3.5 Cortical Screw hmang rawh) |
5100-2601 ah zawh theih a ni | 5 a awm L | 4.2 | 12.5 | 97 |
| 5100-2602 ah zawh theih a ni | 7 holes a awm L | 4.2 | 12.5 | 124 | |
| 5100-2603 ah zawh theih a ni | 9 holes a awm L | 4.2 | 12.5 | 151 | |
| 5100-2604 ah zawh theih a ni | 11 khur a ni L | 4.2 | 12.5 | 178 | |
| 5100-2605 ah zawh theih a ni | 13 a awm L | 4.2 | 12.5 | 205 | |
| 5100-2606 ah zawh theih a ni | 5 a awm R | 4.2 | 12.5 | 97 | |
| 5100-2607 ah zawh theih a ni | 7 holes a awm R | 4.2 | 12.5 | 124 | |
| 5100-2608 ah zawh theih a ni | 9 holes a awm R | 4.2 | 12.5 | 151 | |
| 5100-2609 ah zawh theih a ni | 11 khur a ni R | 4.2 | 12.5 | 178 | |
| 5100-2610 ah zawh theih a ni | 13 a awm R | 4.2 | 12.5 | 205 |
Thlalak tak tak

Blog a ni
Distal lateral tibial locking plate hi damdawi lam hmanrua a ni a, distal tibia ruh tliak te fixation atan hman a ni. He device hian ruh tliak chu stable fixation a pe a, damlo chu a hmaa mobilization a siamsak bawk. He thuziak ah hian distal lateral tibial locking plate chungchang chipchiar takin kan sawi dawn a, a design, a indications, surgical technique, complications, leh outcomes te pawh kan sawi dawn a ni.
Distal lateral tibial locking plate hi plate chi khat a ni a, distal tibia ruh tliak enkawlna atana hman thin a ni. He plate hi ruh chi hrang hrangte chu stable fixation pe thei tura siam a ni a, damlo chu a hmaa mobilization theih a ni. Plate hi titanium a siam a ni a, screw dahna tur khur tam tak a nei bawk.
Distal lateral tibial locking plate hian design danglam tak a nei a, chu chuan distal tibia chu stable fixation a siam thei a ni. Plate hian proximal end leh distal end a nei a, tibia shape nena inmil turin contoured a ni. Plate hian screw hole tam tak a nei a, screw te hi locking fashion-in an dah lut bawk. Screw-te locking mechanism hian screw-te chu a hnungtawlh loh nan a veng a, ruh chi hrang hrangte chu stable fixation a pe bawk.
Distal lateral tibial locking plate hi distal tibia ruh tliak enkawlna atan hman a ni. Plate hi a bik takin, hmanlai dan hmanga tihngheh harsa tak, ruh tliak enkawlna atan a tangkai hle. Hei hian fracture comminuted emaw fragment tam tak nei emaw a huam a ni. Plate hi ankle joint bula awm fracture enkawlna atan pawh a tangkai hle.
Distal lateral tibial locking plate atana surgical technique hman danah chuan ruh tliak tawhte chu open reduction leh internal fixation a ni. Plate hi tibia pianzia nena inmil turin contoured a ni a, ruh lateral aspect-ah dah a ni. Screw te chu locking fashion-in an dah a, plate chu ruh lamah an nghet tlat a ni.
Distal lateral tibial locking plate hman avanga harsatna awm thei chu infection, nonunion, malunion, leh hardware failure te a ni. Surgical incision awmna hmunah emaw, hardware chhehvelah emaw infection a awm thei. Nonunion leh malunion a awm thei a, ruh chi hrang hrang a dam tha lo a nih chuan. Hardware failure hi screw emaw plate emaw a chhe emaw, a back out emaw a nih chuan a awm thei.
Distal lateral tibial locking plate hman hi distal tibia ruh tliak enkawlna atan a tangkai hle tih hmuhchhuah a ni. Plate hian ruh chi hrang hrangte chu stable fixation a pe a, damlo chu a hmaa mobilization a siamsak bawk. Zirna hrang hrangah chuan plate hman hian union rates sang tak leh clinical outcome tha tak a thlen tih hmuhchhuah a ni.
Distal lateral tibial locking plate hi distal tibia ruh tliak enkawlna atana hmanraw tangkai tak a ni. Plate hian ruh chi hrang hrangte chu stable fixation a pe a, damlo chu a hmaa mobilization a siamsak bawk. Mahse, he device hi harsatna awm thei a ni a, damlo uluk taka thlan leh surgical technique hi a tha ber tur atan a pawimawh hle.
Distal lateral tibial locking plate tih hi eng nge ni? Distal lateral tibial locking plate hi damdawi lam hmanrua a ni a, distal tibia ruh tliak te fixation na atan hman a ni.
Distal lateral tibial locking plate hian engtin nge hna a thawh? Distal lateral tibial locking plate hian ruh tliak chu stable fixation a pe a, damlo chu a hmaa mobilization a siamsak bawk. Plate hi titanium a siam a ni a, screw dahna tur khur tam tak a nei bawk.
Distal lateral tibial locking plate hman dan tur engte nge ni? Distal lateral tibial locking plate hi distal tibia ruh tliak enkawlna atan hman a ni. A bik takin, hmanlai dan hmanga stabilize harsa, comminuted fracture emaw, ankle joint bula fracture emaw te tan a tangkai hle.
Distal lateral tibial locking plate hman hian eng harsatna nge a thlen theih? Distal lateral tibial locking plate hman avanga harsatna awm thei chu infection, nonunion, malunion, leh hardware failure te a ni. Damlo uluk taka thlan leh surgical technique hi optimal outcome atan a pawimawh hle.
Distal lateral tibial locking plate hman hian eng nge a chhuah? Zirna hrang hrangah chuan distal lateral tibial locking plate hman hian union rates sang tak leh clinical outcome tha tak a thlen tih hmuhchhuah a ni. Mahse, mimal outcome chu damlo bik leh fracture characteristics a zirin a danglam thei.
Thil siam chhuah te