Product Description chungchang
CZMEDITECH siam 2.7 mm Mini Recontruction Locking Plate hi ruh tliak enkawlna atan hman theih a ni a, trauma repair leh kut zungtang leh metatarsal ruh tliak siamthatna atan hman theih a ni.
He series of orthopedic implant hian ISO 13485 certification a paltlang tawh a, CE mark leh specification hrang hrang nei thei a ni a, chungte chu trauma repair leh finger leh metatarsal bone fracture siamthatna atan a tha a ni. Hman a awlsam a, hman laiin a nuam a, a nghet bawk.
Czmeditech thil thar leh thil siamna technology tihchangtlun tak hmang hian kan orthopedic implants te hian thil danglam bik an nei a ni. A rit zawk a, a chak zawk a, tenacity sang tak a nei bawk. Plus, allergic reaction a tichhuak tlem zawk bawk.
Kan thil siam chungchang chipchiar zawka hriat duh chuan i duh angin min rawn biak theih reng e.

| Thil siam chhuah te | REF | Holes a awm | Dung |
| 2.7S Mini Reconstruction Locking Plate (A thuk zawng:1.5mm, A zau zawng: 6.5mm) a ni. | 021150004 | 4 a awm | 33mm a ni |
| 021150006 | 6 a awm | 49mm a ni | |
| 021150008 | 8 a awm | 65mm a ni | |
| 021150010 | 10 a ni | 81mm a ni |
Thlalak tak tak

Blog a ni
Medical technology a lo thang zel a, tunah chuan orthopaedic surgeon-te chuan fracture fixation procedure complex tak tak chu chiang zawk leh dik zawkin an ti thei ta a ni. Chutiang technology pakhat chuan orthopaedic surgery lama thil tidanglamtu chu 2.7 mm mini reconstruction locking plate hi a ni. He thuziak-ah hian he hmanraw thar, a hman dan te, a hlawkna te, leh a tihkhawtlai theihna te chungchang kaihhruaina kimchang tak kan pe ang.
A ke ruh tliak hi a awm fo a, natna nasa tak leh hnathawh that lohna nasa tak a thlen thei bawk. Fracture enkawlna tum ber chu stable fixation neih a ni a, hei hian a hmaa mobilization leh hnathawhna siam that theihna a siam a ni. Fracture fixation hman dan hlui, casting leh external fixation te hi hun rei tak immobilization leh functional outcome tlahniam nen a inzawm tih an sawi. Tun hnaiah locking plate technology chu fracture fixation hmanraw hlui aiin a danglamna beisei awm tak a ni ta a ni.
2.7 mm mini reconstruction locking plate chu titanium emaw stainless steel emaw atanga siam plate te tak te, te tak te, ruh te tak te, kut, kutphah, ke leh ke ruh te a ruh tliak te siamthat nan hman a ni. Plate chu ruh lamah screw hmangin plate chhungah an lock a, chu chuan stable fixation a pe a ni.
2.7 mm mini reconstruction locking plate hman hian fracture fixation hman dan pangngai aiin hlawkna engemaw zat a nei a ni. Chung zingah chuan:
Locking plate hian screw te chu plate chhungah lock in stable fixation a pe a, chu chuan screw te chu a tizau a, a hnua reduction a hloh loh nan a veng a ni.
Locking plate-in fixation nghet tak a pek avangin mobilization hmasa ber a awm thei a, hei hian functional outcome tha zawk a thlen thei a, recovery time pawh a ti tlem thei bawk.
Locking plate hman hian ruh chunglam zau zawkah load chu a sem darh avangin implant failure hlauhawmna a ti tlem a ni.
Locking plate hian traditional plate leh screw nena khaikhin chuan biomechanical stability tha zawk a pe tih hmuhchhuah a ni a, hei hian damna tha zawk leh functional outcome tha zawk a thlen thei a ni.
Locking plate hman hian ruh grafting mamawhna a ti tlem thei a, stable fixation a pe a, damna a tichak bawk.
2.7 mm mini reconstruction locking plate hi ruh te tak te, kut, kutphah, ke leh ke ruh atanga hmuh te, ruh tliak te fixation atan hman a ni. A bik takin a hriattirna te chu:
2.7 mm mini reconstruction locking plate hmang hian distal radius fracture siam that theih a ni a, hei hi wrist fracture chi khat a ni.
Scaphoid ruh hi ruh te tak te, kutphah chhunga awm a ni a, a chhe thei hle. 2.7 mm mini reconstruction locking plate hmang hian scaphoid fracture siam that theih a ni a, hei hi enkawl harsa tak a ni thei.
2.7 mm mini reconstruction locking plate hmang hian ke ruh tliak te chu siam that theih a ni a, hei hi hliam tlangpui a ni a, natna nasa tak a thlen thei a ni.
2.7 mm mini reconstruction locking plate hmang hian ke ruh ruh tliak, metatarsals leh phalanges-a hmuh theih te chu siam that theih a ni.
2.7 mm mini reconstruction locking plate hian ṭhatna tam tak a neih laiin, a tihkhawtlai ṭhenkhat pawh a awm bawk
hmang. Chung zingah chuan:
2.7 mm mini reconstruction locking plate hi ruh te tak tea hman tur atana siam a ni a, ruh lian zawk emaw, ruh tliak complex zawk emaw tan pawh a tha lo.
Locking plate hmanna atan hian technical expertise a ngai a, surgeon chuan device leh a hman dan tur a hriatthiam a ngai a ni.
Surgery dang ang bawkin, locking plate hman hian harsatna a awm thei a ni. Chung zingah chuan infection, implant failure, leh nerve emaw vascular injury te a tel.
2.7 mm mini reconstruction locking plate hi technology beisei awm tak a ni a, fracture fixation hmanlai method aiin hlawkna engemaw zat a nei a ni. Stable fixation a pe a, mobilization hmasa ber a siam thei a, implant failure hlauhawmna a ti tlem bawk. Mahse, a tih theih lohna leh a harsatna awm thei te hriatthiam a pawimawh hle. A pum puiin, 2.7 mm mini reconstruction locking plate hman hian an taksa peng hrang hranga ruh te tak te ruh tliak nei damlote tan functional outcome a ti tha thei a, recovery time pawh a ti tlem thei bawk.
Recovery time hi a ruh tliakna hmun leh a nasat dan azirin a danglam thei a, chubakah damlo pakhat zel dam theihna a zirin a inang lo thei bawk. Mahse, locking plate hman hian mobilization hmasa ber a siam thei a, fracture fixation hmanlai nena khaikhin chuan a dam rei zawk thei bawk.
Locking plate hi a tlangpuiin a ruh chu a dam leh a, ruh a chak leh hma loh chuan a hmunah a awm reng thin. Hei hi a ruh na hmun leh a nasat dan azirin a danglam thei a, mahse a tlangpuiin kar engemaw zat atanga thla engemaw zat chhung a ni.
Ni e, locking plate hi X-ray leh imaging study dang ah pawh hmuh theih a ni. Hei hi damna kalphung enfiahna leh fixation dinhmun nghet leh nghet loh tehna atan a tangkai thei hle.
A then phei chuan locking plate chu a ruh tliak a dam hnuah lakchhuah theih a ni a, chu chuan ruh natna a thlen emaw, ruh hnathawh a tibuai emaw a nih chuan. Mahse, he thutlukna hi damlo surgeon nen inrawnkhawmin siam tur a ni.
Locking plate lakchhuah hian harsatna a awm thei a, chu chu infection emaw nerve injury emaw a ni. Mahse, heng hlauhawmnate hi a tlangpuiin a tlem a, surgical technique dik tak leh postoperative care hmangin a tlem thei hle.
Thil siam chhuah te