Unemibuzo?        +86- 18112515727        ingoma@orthopedic-china.com
Please Choose Your Language
Ulapha: Ikhaya » Izindaba » Izinsiza zepuleti lokukhiya » Ukuhlinzwa Okuyimpumelelo Kwe-Distal Radius Fracture e-Mexico — Kusetshenziswa I-CZMEDITECH VA Locking Plate System

Ukuhlinzwa Okuyimpumelelo Kwe-Distal Radius Fracture e-Mexico — Kusetshenziswa I-CZMEDITECH VA Locking Plate System

Ukubuka: 0     Umbhali: Isikhathi Sokushicilela Isihleli Sesayithi: 2025-10-30 Umsuka: Isayithi

inkinobho yokwabelana ye-facebook
inkinobho yokwabelana ye-twitter
inkinobho yokwabelana ngomugqa
inkinobho yokwabelana ye-wechat
inkinobho yokwabelana ye-linkedin
inkinobho yokwabelana ye-pinterest
yabelana ngale nkinobho yokwabelana

Ukuhlinzwa Okuyimpumelelo Kwe-Distal Radius Fracture e-Mexico — Kusetshenziswa I-CZMEDITECH VA Locking Plate System


Uhlolojikelele lwekesi

E-Tlalixtac de Cabrera State Hospital, eMexico, ukuhlinzwa kwe-distal radius fracture kwenziwa ngempumelelo kusetshenziswa i-VA Distal Radius Locking Plate ehlinzekwe yi-CZMEDITECH, umkhiqizi ohamba phambili wokufakelwa kwamathambo waseChina.

Ukusebenza, okuholwa nguDkt. José Alfredo Rios Melchor, kufinyelele ukuqondana kwe-anatomical okunembile kanye nokululama kwesiguli ngokushesha - okugqamisa ukuthi izinhlelo zesimanje zokulungisa ukuhlukumezeka zithuthukisa kanjani imiphumela kulo lonke elaseLatin America.

Incazelo Yecala

Isiguli esineminyaka engu-53 ubudala siphukile eduze kwesihlakala ngemva kokuwa. Ithimba lezokwelapha likhethe ukulungiswa kwangaphakathi lisebenzisa ipuleti lokukhiya i-engeli ehlukile ye-distal radius, eliqinisekisa ukuncishiswa kwe-anatomical kanye nokuhlanganisa kusenesikhathi.

Isithombe sangaphambi kokuhlinzwa

I-Distal Radius Fracture Surgery eMexico - Ukusebenzisa i-CZMEDITECH VA Locking Plate System1


Leli cala libonisa ukuthi ukulungiswa kwepuleti lokukhiya kungabuyisela kanjani ukuzinza nokusebenza okuhlangene, ikakhulukazi ekuqhekekeni okuyinkimbinkimbi kwe-intra-articular ye-distal radius.

Ukuhlolwa Kwangemva Kokuhlinzwa kanye Namaphuzu Avelele

Ukuhlinzwa kwakusebenza kahle futhi kwaqedwa ngokunemba kochwepheshe kusetshenziswa izinsimbi ze-CZMEDITECH ze-orthopedic.

Ukuhlolwa kwangemva kokuhlinzwa kwembule ukuqondanisa okuhle kakhulu, ukulungiswa okuzinzile, nokunyakaza kwamalunga kwangaphambi kwesikhathi.

I-Distal Radius Fracture Surgery eMexico - Ukusebenzisa i-CZMEDITECH VA Locking Plate System2   I-Distal Radius Fracture Surgery eMexico - Ukusebenzisa i-CZMEDITECH VA Locking Plate System3

I-implant esetshenzisiwe:

I-VA Distal Radius Locking Plate (25.5 mm, 2-hole)

Isithombe se-Postoperative

I-Distal Radius Fracture Surgery eMexico - Ukusebenzisa i-CZMEDITECH VA Locking Plate System4


Lokhu kuhlinzwa kwepuleti le-distal radius kubonisa ukuthi izimila ze-titanium alloy ze-biocompatible zifaka isandla ekwelapheni amathambo futhi zinciphise ukucasuka kwezicubu ezithambile ezizungezile.

Izinsimbi Ezisetshenzisiwe

I-Distal Radius Fracture Surgery eMexico - Ukusebenzisa i-CZMEDITECH VA Locking Plate System5I-Distal Radius Fracture Surgery eMexico - Ukusebenzisa i-CZMEDITECH VA Locking Plate System6

Amathuluzi ahlanganisa ama-forcep okunciphisa amathambo, iziqondiso zokubhoboza, nama-screwdrivers aklanyelwe ngokukhethekile ukulungiswa kwe-radius fracture - ukuqinisekisa ukunemba okuphezulu phakathi nenqubo yokuhlinzwa.

Qaphela: Izibhedlela nodokotela okukhulunywe ngabo bangamagama mbumbulu.

Ukuqonda Komtholampilo: Ukubaluleka Kokulungiswa Kwepuleti Lokukhiya I-Distal Radius

Ukuphuka kwe-distal radius kuphakathi kwezingozi ezivame kakhulu ezingenhla emhlabeni jikelele. Ukulungiswa okuzinzile okunepuleti elishintshashintshayo le-distal radius kubalulekile ukuze kugcinwe ukunyakaza kwesandla nokuvimbela izinkinga zangemva kokuhlinzwa.

I-CZMEDITECH VA Locking Plate System inikezela nge-screw trajectory ethuthukisiwe, amandla aphezulu okudonsa, kanye nokuhambisana namasu okuhlinza ahlasela kancane. Isetshenziswa kabanzi ekwelapheni i-osteoporotic bone, ukuphuka okuhlangene, kanye nokulungiswa kokukhubazeka kwangemva kwengozi.

Ngokuhlanganisa ubunjiniyela obunembayo kanye ne-titanium ye-biocompatible, i-CZMEDITECH inikeza izixazululo ezinokwethenjelwa kodokotela bamathambo emhlabeni wonke, ukuvala igebe phakathi kwezifakelo ezingabizi kakhulu nezisebenza kahle kakhulu.

I-Global Perspective - I-Orthopedic Innovation kulo lonke elaseLatin America

Ukuphumelela kwaleli cala eMexico kubonisa ukubambisana okukhulayo phakathi kwabakhiqizi bamathambo baseShayina kanye nezibhedlela zaseLatin America.

Ngesitifiketi se-CE ne-ISO 13485, izimila ze-CZMEDITECH zamathambo zithenjwa emazweni angaphezu kuka-50, okuhlanganisa iMexico, iBrazil, iColombia, neChile.

Amasistimu abo okulungisa ukuhlukumezeka, njengamapuleti okucindezela okukhiya (LCP) nezinzipho ze-intramedullary, aklanyelwe ukuhlangabezana nezidingo zomtholampilo zomhlaba wonke kuyilapho kugcinwa amanani athengekayo ezibhedlela nabasabalalisi.

Isidingo Esikhulayo Sokufakwa Kwama-Orthopedic eMexico

I-Mexico nezinye izifunda zaseLatin America zibona ukukhula okusheshayo kokuhlinzwa kwamathambo - ikakhulukazi ukulungiswa kwe-distal radius fracture kanye namacala okuhlukumezeka esihlakaleni.

Izibhedlela ziya ngokuya zikhetha ubuchwepheshe bepuleti lokukhiya ngoba lenza ukulungiswa okuqinile, ukuvuselelwa kusenesikhathi, kanye nemiphumela ethembekile.

Lo mkhuba ubonisa ukwamukelwa kwemikhiqizo yamathambo yaseShayina ezimakethe zamazwe ngamazwe okuhlukumezeka, okuqinisa indima ye-CZMEDITECH njengozakwethu othembekile wokuqamba izinto ezintsha zokuhlinza.

FAQ

Q1: Isetshenziselwa ini ipuleti lokukhiya irediyasi ekude?

I-A1: Idizayinelwe ukwelapha ukuphuka ekugcineni kwethambo le-radius, iqinisekisa ukuzinza kwe-angular kanye nokusekela ukunyakaza kwesihlakala kwangaphambi kwesikhathi ngemva kokulimala.

Q2: Kungani uhlelo lwe-VA (Variable Angle) lubalulekile?

I-A2: Uhlelo lwe-VA luvumela odokotela abahlinzayo ukuthi balungise izikhombisi-ndlela eziyisikulufa ukuze zilungiswe kahle, zenze zifaneleke ukuphuka okuyinkimbinkimbi kanye ne-osteoporotic.

Q3: Yini eyenza izimila ze-CZMEDITECH zithembeke?

I-A3: Ukufakelwa ngakunye kukhiqizwa ngaphansi kwezinhlelo zekhwalithi eziqinisekisiwe ze-CE kanye ne-ISO 13485, kusetshenziswa i-titanium yezinga lezokwelapha ukuze kuhambisane ne-biocompatibility namandla.

Q4: Ingabe imikhiqizo ye-CZMEDITECH yamathambo iyatholakala eMexico naseLatin America?

I-A4: Yebo, inkampani inikeza amapuleti okukhiya, amasistimu okuhlukumezeka, nokufakelwa komgogodla ezibhedlela kulo lonke elaseLatin America, eYurophu nase-Asia.

I-Q5: Abasabalalisi noma odokotela abahlinzayo bangaxhumana kanjani ne-CZMEDITECH?

A5: Vakashela www.czmeditech.com noma i-imeyili song@orthopedic-china.com ngezicelo zekhathalogi, izingcaphuno, nokusekelwa kwezobuchwepheshe.

Yamaphuzu Avelele Ezobuchwepheshe


Yengcaciso Imininingwane
Umkhiqizo I-VA Distal Radius Locking Plate
Okubalulekile I-Medical-Grade Titanium Alloy
Izici Idizayini ye-Angle eguquguqukayo, i-Biocompatible, Ukulungiswa Okuzinzile
Sebenzisa Ikesi I-Distal Radius kanye Nokuphuka Kwesihlakala
Isitifiketi CE, ISO13485
Umkhiqizi I-CZMEDITECH (China)
Ukusetshenziswa Kwezokwelapha Mexico, Latin America

Xhumana nathi

Xhumana Nochwepheshe Bakho Be-CZMEDITECH Orthopedic

Sikusiza ukuthi ugweme izingibe zokuletha ikhwalithi futhi wazise isidingo sakho samathambo, ngesikhathi kanye nesabelomali sakho.
Inkampani Changzhou Meditech Technology Co., Ltd.

Isevisi

Buza Manje
© COPYRIGHT 2023 CHANGZHOU MEDITECH TECHNOLOGY CO., LTD. WONKE AMALUNGELO AGODLIWE.