Zawhna i nei em?        +86- 18112515727       a ni.  hla@orthopedic-china.com ah hian a awm a.
Please Choose Your Language
I awmna hmun: In » Chanchinthar » Spine Resource 1000 a ni. » Mexico rama Cervical Fusion Surgery hmasawn tak chu UNI-C Standalone Cage hmangin | CZMedItech Spine hmanga siam a ni.

UNI-C Standalone Cage hmanga Mexico rama Cervical Fusion Surgery hmasawn tak | CZMedItech Spine hmanga siam a ni.

A rilru a buai em em a 0     , a rilru a hah em em bawk a, a rilru a buai em em bawk a. Hmun

Facebook Sharing button a awm bawk.
Twitter atanga Sharing button a awm bawk.
Line Sharing button a awm bawk.
WeChat hmanga Sharing tih a ni.
LinkedIn Sharing button a awm bawk.
Pinterest hmanga Sharing tih a ni.
ShareHe Sharing button hi a awm em?

Mexico rama Cervical Fusion Surgery hmasawn tak chu UNI-C standalone cage hmangin a ni.

Clinical background a ni a .

Spinal degenerative diseases leh tar population a tam zel avangin khawvel pumah spinal fusion procedure mamawhna a sang zel a ni. Interbody fusion cages hian spinal implant technology lama hmasawnna nasa tak a entir a, clinical outcome tha zawk a pe a ni. CZMedItech-a interbody fusion cage system hi Mexico leh Latin America ram pumah te hman a ni nasa hle a.

Case thlirletna .

Tun hnaiah Puebla, Mexico-a medical center-ah Dr. José Martínez leh a team-te chuan CZMedItech-a interbody fusion cage hmangin anterior cervical discectomy and fusion (ACDF) procedure chu hlawhtling takin an ti a. Damlo chu postoperative-in a dam tha hle a, symptoms improvement nasa tak a nei bawk.

Damlote imaging study leh clinical presentation te kimchang taka an zirchian hnuah Dr. José Martínez chuan interbody fusion cage hmanga cervical fusion chu surgical approach tha ber a ni tih a hmuchhuak a.

Case presentation 1000 a ni.

Damlo chipchiar tak tak te .

Hming: Carlos Rodríguez tih a ni.

Kum: Kum 54 .

Gender: Mipa .

Clinical presentation neih a ni a.

Kawng na leh veilam upper extremity radicular pain thla 3 chhung

kut veilam a numbness .

Cervical range of motion tlem .

Diagnosis 1.1.

C5-C6 disc herniation chu spinal cord leh nerve root compression hmanga tih a ni.

Degenerative disc natna .

Cervical radiculopathy .

Operation hmaa imaging tih te .

Zapopan, Mexico-a fusion surgery neih hmain preoperative cervical MRI-ah disc herniation leh opll a awm tih hmuhchhuah a ni.

Intraoperative imaging hmanga siam chhuah a ni.

UNI-C standalone cervical cage placement a awm laiin anterior cervical fusion laiin czmeditech 1 hmangin intraoperative view
UNI-C standalone cervical cage placement a intraoperative view Czmeditech 2 hmanga anterior cervical fusion

Operation hunlai dinhmun .

Postoperative-a imaging hmanga thil siam chhuah .

Mexico rama UNI-C cervical cage implantation hnua fixation leh alignment nghet tak lantir postoperative X-ray
Mexico rama UNI-C cervical cage implantation hnua fixation leh alignment nghet tak lantir postoperative X-ray 2

Damlo hian a kawng natna leh a veilam upper extremity radicular pain chu postoperatively-ah nasa takin a ti reh a, veilam kut natna a reh zauh zauh bawk. Follow-up imaging-ah chuan stable cage positioning, maintained disc height, leh bone fusion chhinchhiahna hmasa te a lang.

Surgical summary 1000 a ni.

Dr. José Martínez chuan Czmeditech interbody fusion cage chu a lawm hle tih a sawi. Cage hian design danglam tak a nei a, chu chuan implant size leh position chu personalized matching atan chiang takin a siamrem thei a ni.

Cage-a surface porous structure hian ruh ingrowth a tichak a, fusion rate a ti sang a ni. Internal cavity chu autograft emaw bone substitute material emaw hmangin a khat thei a, chu chuan bone fusion a ti awlsam lehzual thei a ni.

Instrumentation system hi design tha tak a ni a, cage nena inmil tak instrument a awm a, surgical step awlsam zawk leh operative time tihtlem a ni.

CZMedItech Uni-C standalone cervical cage sterilized implant a ni a, a hnah hi a hring a, a hnah hi a hring a, a hnah hi a hring bawk a.

Uni-C standalone cage a ni.

CZMedItech Cervical Fusion Surgical Instruments Set UNI-C cage implantation-a hman thin

Uni-C standalone cage hmanrua a ni.

CZMedItech Uni-C standalone cervical cage sterilized implant chu a awm a, a hmanna tur hmun leh a hmanna tur hmun a awm lo.

Uni-C Standalone Cage Product Model a ni a, a man pawh a tlawm hle.

CZMedItech interbody fusion cage a ni.

CZMedItech interbody fusion cage hian spinal implant technology lama hmasawnna thar ber a entir a, stability tha ber pe thei tur leh cervical leh lumbar spinal procedure-a ruh fusion chak tak siam tura ruahman a ni.

Thil pawimawh tak tak te .

  • Intraoperative size leh angle adjustment na tur modular design a awm bawk.

  • Bone ingrowth tichak turin porous surface structure .

  • Bone fusion tha ber tur atan internal graft chamber lian tak a awm bawk.

  • Peek leh Titanium Alloy Materials ah te a awm

  • Minimally invasive surgical technique hmanga hman theih a ni

  • Precision instrumentation hmanga dah dan dik tak .

Technical lam thila thil chiang tak tak .

  • A san zawng tur: 6mm atanga 14mm thleng 1mm increment ah

  • Lordotic angle: 0°, 4°, 8°, leh 12° te a ni.

  • Footprint size: A te, a lian, a lian .

  • Operative assessment neihna tur Radiopaque marker te .

  • sterile packaged a ni a, hman theih turin a inpeih tawh bawk.

Indication te .

CZMedItech interbody fusion cage hi cervical leh lumbar spin-a hman tur a ni a, chu chu degenerative disc natna, spinal instability, spondylolisthesis, leh spinal fusion mamawhna hmuna revision surgery neihna atana hman tur a ni.

CE certified a ni a.
FDA chuan a pawm a ni.
ISO 13485 a ni.

CZMedItech Interbody Fusion Cage Product Features .

Thil thar siam chhuah .

Unique modular structure chuan fit leh stable fixation tha ber neih theih nan size leh angle intraoperative adjustment dik tak a siam thei a ni.

Biocompatibility .

Medical-grade peek emaw titanium alloy atanga siam niin biocompatibility tha tak leh mechanical property tha tak a nei a, rejection risk a ti tlem hle.

Bone fusion promotion .

Surface porous structure design with large internal graft chamber hian ruh ingrowth a tichak tha hle a, fusion hlawhtlinna a tichak bawk.

Instrumentation system 1000 a ni.

Specialized precision instrument system leh user-friendly design hmanga siam hian surgical time a ti tlem a, a dikna a ti tha bawk.

Zawhna zawh fo thin .

Interbody fusion cage tih hi eng nge ni?

Interbody fusion cage chu fusion procedure-a hman thin spinal implant a ni. A design danglam tak chuan surgeon-te chu implant height leh angle intraoperative-a dik taka siam theihna tur a siamsak a, chu chu anatomical matching tha ber leh stable fixation neih theihna turin 'modules' size hrang hrang a dah a ni.

Interbody fusion cages hian traditional cages nena khaikhin chuan eng hlawkna nge a neih?

Interbody fusion cages hian intraoperative adjustability a pe a, chu chuan implant size tam tak mamawhna a ti tlem a; endplate matching tha zawk pe la, subsidence risk tihhniam; leh feature designs te chu bone fusion tihhmasawn nan biomechanical requirements zawm tha zawk an ni.

Eng spinal condition nge interbody fusion cages hman thin?

Anni hi degenerative disc natna, spinal instability, disc herniation, spinal stenosis, spondylolisthesis, leh spinal fusion mamawh condition dangte tan an tarlang a ni. Level hrang hrangah hman theih a ni a, chung zingah chuan cervical, thoracic, leh lumbar region te pawh a tel.

Tawpna

He case hian spinal fusion surgery-a CZMedItech-a interbody fusion cage hman hlawhtling a nihzia a tilang chiang hle. Design thar leh thil siamchhuahna kalphung thar hmangin, he thil siam hian spine surgeon-te chu damlote’n spinal stability leh function an siam ṭhat leh theih nan solution ṭha zawk a pe a ni.

Damlo hian follow-up-naah symptoms leh radiological evidence-ah hmasawnna nasa tak a nei a, radiological evidence a nei bawk. CZMeditech hian khawvel puma damlote tana damdawi tha zawk pek theihna tur orthopedic implant quality sang tak siam chu a tum tlat a ni.

CZMedItech damdawi hmanrua | Interbody Fusion Cage Case Study 1000 a awm bawk.

NOTE: Hospital leh doctor hmingte hi hming lem a ni. Thlalak zawng zawng hi entir nan a ni.

Kan rawn biak theih reng e

I CZMedItech orthopedic mithiamte zawt rawh

I orthopedic mamawhna, a hun leh a budget-a i mamawh tur thilte delivery-na atana harsatna awmte chu pumpelh turin kan pui che a ni.
A rilru a hah lutuk chuan a rilru a buai em em a.

Thawhna

Inquiry tunah hian .
© Copyright 2023 Changzhou Meditech Technology Co., Ltd. Thuneihna zawng zawng a nei.