Views: 32 Author: Site Editor A chhuah hun: 2023-08-25 A chhuahna: Hmun
ANI distal medial tibial locking plate hi surgical implant a ni a, biocompatible material stainless steel emaw titanium emaw hmanga siam a ni. Tibia distal (lower) portion, a bik takin ruh medial (inner) aspect-a nghawng nei, ruh tliak leh ruh natna dangte enkawlna atana siam a ni. He plate hi orthopedic surgery-a hmanraw pawimawh tak a ni a, ruh tliak chu stability leh support a pe a, damna dik tak a siamsak a ni.
Locking plate te pawh a tel distal medial tibial locking plates , hian fracture enkawlna kawngah hmasawnna nasa tak a entir a ni. Plate leh ruh inkara compression-a innghat plate hlui ang lo takin, locking plate-ah hian specialized screw hmangin plate chhung ngeiah lock lut a ni. He locking mechanism hian ruh tliak tan fixation him zawk leh nghet zawk a pe a ni.
ANI distal medial tibial locking plate hian thil pawimawh engemaw zat a huam a:
Plate taksa ber chu a flat a, tibia pianzia nena inmil turin contoured a ni. He contouring hian ruh chungah snug fit a siam a, force te pawh a ruala sem darh turin a pui bawk.
Plate hian strategically placed holes tam tak a nei a. Heng holes te hi locking screw awm theihna tura siam a ni a, chu chu plate chu ruh nena inzawm tlat turin dah a ni.
Locking screw hi system-a thil pawimawh tak a ni. Heng screw te hi damlo mamawh bik ang zela sei leh diameter hrang hranga awm a ni. An design danglam tak avang hian plate nen hian him takin an inzawm thei a, an che thei lo va, an inthlak danglam thei lo bawk.

Surgery tih danah hian a distal medial tibial locking plate hian a tlangpuiin hengte hi a zawm thin:
Orthopedic surgeon hian tibial fracture awm dan leh a nasat dan chu diagnostic imaging X-ray emaw CT scan ang chi hmangin a zirchiang thin.
Tibia ruh tliak lai chu surgical incision siam a ni.
Surgeon chuan ruh tliak tawhte chu uluk takin a siam ṭha a, chu chuan a inmil lehzual thei a ni. Hlawhtling taka tihdamna atan chuan tihtlem dik hi a pawimawh hle.
Chumi distal medial tibial locking plate chu tibia medial aspect-ah dah a ni a, fracture site nen a inmil a ni. Plate chu ruh pianzia nen a inmil a, chu chuan secure fit a pe a ni.
Locking screw te chu plate chhunga khur atang leh tibia chhungah dah a ni. Heng screw te hi ruh tliak te chu a innghah theih nan nghet takin an khih a ni.
Surgical incision chu suture, staple emaw, khar dan dang emaw hmangin an khar thin.

A hman dan tur distal medial tibial locking plate hian hlawkna engemaw zat a nei a:
Locking plate hian stability danglam tak a pe a, non-union emaw malunion emaw ang chi complication awm theihna a ti tlem a ni.
Damlote chuan locking plate-in stability a pek avangin weight-bearing leh physical therapy an tan hma thei fo a, hei hian damna a tikhawtlai thei a ni.
Locking mechanism hian screw mamawh zat a ti tlem a, hei hian natna kai theihna a ti tlem a ni.
Distal medial tibial locking plates hian damna hmasa ber pawimawh takah alignment dik tak a thlawp a, hei hian fracture damna tha ber a tichak a ni.
Surgery zawhah damlote hian rehabilitation process an nei tlangpui a, chutah chuan:
Damlote hian natna kai loh nan post-operative care an dawng a, pain management leh antibiotics te pawh an dawng a ni. Surgery hliam thianghlim leh vawt taka vawn reng hi a pawimawh hle.
Rehabilitation-ah hian ke chakna leh kal theihna tihchangtlun nan physical therapy a ngai fo thin. Locking plate awmna hian he phase chhung hian controlled movement a siam thei a ni.
Orthopaedic surgeon nena follow-up visit neih fo hi a pawimawh hle a, damna kal zel dan enfiah a, ngaihtuahna awm apiang chinfel a ni.

Q : Tibia fracture hi eng chen nge a distal medial tibial locking plate a tihdam theih nan?
A : Dam hun chhung hi a ruh tliak nasat dan azirin a inang lo a, mahse a tlangpuiin kar engemaw zat atanga thla engemaw zat chhung a ni.
Q : Hmannaah hian hlauhawmna a awm em distal medial tibial locking plate te chu a awm a?
A : Harsatna hi a tlem hle laiin, a hlauhawm thei chu natna hrik kai, implant chhiat, emaw, a bul hnaia structure hliam emaw a ni. I surgeon chuan heng hlauhawmnate hi a sawipui ang che.
Q : Tibia a dam hnuah locking plate hi lakchhuah theih a ni em?
A : A then phei chuan plate hi harsatna emaw thil dang emaw a awm chuan lakchhuah theih a ni. I surgeon chuan lakchhuah a ngai em tih a zirchiang ang.
Q : Operation hnua taksa tihchakna hi a distal medial tibial khar theihna plate a ni?
A : A tirah chuan taksa tihchakna khapna a awm thei a, mahse hengte hi a dam chhoh zelnaah zawi zawiin tihbo a ni a, i surgeon leh physical therapist kaihhruaina hnuaiah.
Q : Engtiang chiahin nge surgery hi a distal medial tibial khar theihna plate a ni?
A : Locking plate hmanga surgery hi a tlangpuiin a hlawhtling hle a, a rah chhuah pawh a tha hle. Mahse, mimal result a inang lo thei a, post-operative care leh rehabilitation zawm hi a pawimawh hle.
Chumi distal medial tibial locking plate hian tunlai orthopedic surgery-ah hmun pawimawh tak a chang a, tibial fracture tan solution him leh nghet tak a pe a ni. A design thar leh fixation mechanism hian damlote outcome a ti tha a, dam leh hun pawh a tikhawtlai bawk. Nangmah emaw, i hriat emaw chuan tibial fracture i hmachhawn a nih chuan, a hlawkna hriatthiamna a distal medial tibial locking plate hian hriatna hlu tak a pe thei a, hlawhtling taka dam leh theihna beiseina a pe thei bawk.
Tan CZMEDITECH , kan nei a, orthopaedic surgery implant leh a kaihhnawih instruments product line kimchang tak kan nei a, a product te pawh a tel spine implant te pawh a awm, intramedullary nail a awm bawk, trauma plate a ni, locking plate a ni, lu (cranial-maxillofacial) a ni, prosthesis hmanga siam a ni, power hmanrua hmanga siam a ni, pawn lam atanga fixator te, arthroscopy hmanga enfiah a ni, ran enkawlna leh an puitu instrument set te.
Chu bakah, doctor leh damlo tam zawkte surgical mamawh phuhrukna tur leh, khawvel pum huapa orthopedic implants leh instruments industry pumpuiah kan company hi inelna nei zawka siam theih nan, product thar siam chhunzawm zel leh product line tihpun zel kan tum a ni.
Khawvel pumah kan export a, chuvang chuan i ti thei ang email address song@orthopedic-china.com ah min rawn biak theih a, free quote i dawng thei a, WhatsApp ah message thawn la, chhanna rang tak +86- 18112515727 .
Distal Femoral Fractures te hi a thliar hranna leh enkawl dan tur
Humeral Shaft Locking Plate: Fracture enkawl dan tur tunlai tak
Distal Volar Radial Locking Plate: Kut ruh tliak enkawlna hmasawn
Distal Femoral Locking Plate hman dan tur kaihhruaina hnuhnung ber
VA Distal Radius Locking Plate: Kut ruh tliak te tan a tha ber
Locking Plate: Technology hmasawn hmanga Fracture Fixation tihchangtlun
Olecranon Locking Plate: Elbow Fracture te tan thil danglam tak a ni
Thil siam chhuah te