5100-66 thleng a ni
CZMedItech 1000 a ni.
Titanium Alloy / Stainless Steel hmanga siam a ni
1 set a ni
CE, ISO 13485 a ni
FedEx, DHL, TNT, EMS, etc. te pawh a awm bawk.
OEM leh ODM a awm bawk
Return / Replacement a ni
Femoral neck fracture a awm chuan internal fixation hman a ni
Variable-Angle Locking Technology
Anatomical Volar Plate Design
chu Osteoporotic Bone
Medical-Grade Titanium siamnaah fixation nghet tak a ni
| A awm theihna: | |
|---|---|
Product sawifiahna .
Locking plate hi orthopedic internal fixation system-a thil pawimawh tak a ni. Screw leh plate inkar locking mechanism hmangin framework nghet tak an siam a, chu chuan ruh tliakte tan rigid fixation a pe a ni. A bik takin osteoporotic damlote tan a tha a, complex fractures, leh surgical scenario-ah chuan precise reduction a ngai a ni.
He series-ah hian 3.5mm/4.5mm pariat-plate, sliding locking plate, leh hip plate te a awm a, naupang ruh thanna atana siam a ni. Anni hian epiphyseal guidance nghet tak leh fracture fixation an pe a, naupang kum hrang hranga awmte chu an pawm a ni.
1.5s/2.0s/2.4s/2.7s series ah hian T-shaped, Y-shaped, L-shaped, condylar, leh reconstruction plate te a awm a, kut leh kea ruh tliak te te tan a tha hle a, locking dik tak leh low-profile design a pe bawk.
He category-ah hian clavicle, scapula, leh distal radius/ulnar plate te chu anatomical shape nei a ni a, hei hian multi-angle screw fixation a siam thei a, hei hian joint stability tha ber a siam thei a ni.
Complex lower limb fractures atana siam niin, he system hian
He series-ah hian pelvic plate, rib reconstruction plate, leh sternum plate te chu trauma na tak leh thorax stabilization atan a awm a.
Foot leh ankle fracture atana siam niin, he system hian metatarsal, astragalus, leh navicular plate te a huam a, fusion leh fixation atan anatomical fit a ni tih a tichiang a ni.


Contouring dik tak neih theihna tur mihring anatomic database hmanga design a ni
Angulated screw options a awm a, hei hian stability a ti sang thei a ni.
Low-profile design leh anatomical contouring hian a chhehvela taksa peng, tendon, leh thisen kalna kawngte a ti na thei lo a, hei hian postoperative complication a ti tlem a ni.
Naupang enkawlna hmun atanga puitling application thlenga sizing kimchang .




Case1 a ni.
Case2 a ni.
<
Product sawifiahna .
VA distal radius locking plate chu anatomically contoured volar plate a ni a, distal radius a fracture te stabilize nan hman a ni. He system hian variable-angle locking screw holes , surgeon-te chu fracture morphology leh patient anatomy angin screw trajectories an siam danglam thei a ni.
VA distal radius plate hnathawh ber chu anatomical alignment siam that a, reduction vawng reng a, distal radius fracture-a angular stability pek a ni a, a bik takin articular surface emaw metaphyseal comminution-a awmte chu a ni.
Fixed-angle plate ang lo takin variable-angle system hian defined cone chhunga screw direction controlled deviation a phal a, hei hian complex intra-articular fracture-ah subchondral support leh fragment capture a ti tha zawk a ni.
VA distal radius locking plate hi wrist fracture condition hrang hrang atan hman a ni a, chutah chuan stable internal fixation a ngai a ni.
Distal radius fracture nghet lo tak tak a awm
Intra-articular distal radius a tichhia a ni
Metaphyseal fracture (metaphyseal ruh tliak) a awm
Kum upa lam damlote ruh natna (osteoporotic fractures) a awm thin
Post-traumatic malunion avanga siamthatna tur fixation ngai
Volar plate fixation hian extensor tendon irritation hlauhawmna a tihziaawm a, direct fracture tihtlem theihna a siam a, chutih rualin kutphah dorsal side-a soft tissue integrity a vawng reng bawk.
Plate hi volar surgical approach hmanga dahna tur bik atana siam a ni a, tunlai wrist fracture management principle nena inmil a ni.
Plate contour hi volar distal radius-a natural anatomy nen a inmil a, positioning dik tak a siam awlsam a, intraoperative adjustment pawh a ti tlem thei hle.
Rounded edges leh low-profile design hian flexor tendons leh a chhehvel soft tissue te irritation a ti tlem a, implantation him zawk a thlawp a, postoperative comfort a ti tha zawk bawk.
Variable-angle locking technology hi he distal radius fixation system-a thil pawimawh ber a ni.
Locking hole tin hian range ruat lawk chhungah angular deviation a phalsak a, chu chuan surgeon-te chu screw-te chu fracture fragment bik emaw subchondral bone zone emaw lam hawiin a direct thei a ni.
Hetiang flexibility hian multifragmentary leh intra-articular fracture-ah fixation strength a ti sang a, chutah chuan screw dah dik tak chu joint surface siamthatna atan a pawimawh hle.
Distal radius locking plate hian mechanical strength leh soft tissue compatibility balance turin anatomical profile refined a nei a ni.
Pre-contouring hian intraoperative bending mamawhna a ti tlem a, plate integrity vawng reng turin a pui a, operative time pawh a ti tawi bawk.
Slim plate design hian soft tissue hnuaiah prominence a ti tlem a, postoperative flexor tendon complication awm theihna a ti tlem a ni.
Screw layout hi radius-a distal leh proximal segment-a fixation tha ber pe thei tura engineer a ni.
Multiple distal locking screw options hian subchondral bone a support a, a dam laiin joint congruity a vawng reng bawk.
Proximal cortical emaw locking screw hmangin shaft segment chu a secure a, chu chuan fracture site zawng zawngah load transfer balanced a siam thei a ni.
VA distal radius locking plate hi medical-grade titanium alloy hmanga siam a ni. clinical leh regulatory beisei angin
Titanium hian biocompatibility tha tak, corrosion resistance, leh mechanical strength a pe a, hei hian hun rei tak chhunga implantation atan a tha hle.
Advanced surface processing hian implant durability a tichak a, bone–implant interaction nghet tak a thlawp bawk.
He system hi standard wrist fracture fixation workflows-a awlsam taka inzawmkhawm theih tura duan a ni.
Plate hi distal radius locking plate instrument system hman tlanglawn tak nen a inmil a, screw insertion tha tak leh fixation dik tak a thlawp a ni.
Plate geometry chiang tak leh instrumentation intuitive tak hian operation hun a tihtlem bakah procedural consistency a ti tha hle.
VA distal radius locking plate hi AO/OTA fracture chi hrang hrang tan a tha hle.
AO/OTA 23-A a hliam
AO/OTA 23-B hmanga tihchhiat a ni
AO/OTA 23-C fractures a awm chuan subchondral support nghet tak leh precise reduction a ngai a ni
Distal radius locking plate zawng zawng hi quality management system khauh tak hnuaia siam vek a ni.
Implant tin hian controlled machining leh inspection an nei a, hei hian geometry leh mechanical performance mumal tak a neih theih nan a pui a ni.
Full material traceability leh batch-level quality control hian khawvel pum huapa regulatory leh clinical mamawhna a thlawp a ni.
VA distal radius locking plate hi khawvel pum huapa sem chhuah leh private-label thawhhona atan hman theih a ni.
CZMEDITECH hian distributor leh medical device company hrang hrangte tan OEM leh branding partnership a pui a ni.
Option hrang hrangah hian regional clinical leh regulatory mamawh phuhruk nan plate configuration, packaging, leh labeling te siam a ni.
Variable-angle locking hmang hian flexible screw placement hmangin complex leh intra-articular fracture fragment te fixation a ti tha zawk a ni.
Awle. Locking screw technology hian osteoporotic bone ah angular stability leh fixation tha zawk a pe a ni.
He system hi volar (palmar) surgical approach hmanga distal radius thlenga siam a ni.
Plate hi a chakna leh biocompatibility atan medical-grade titanium alloy hmanga siam a ni.
Product series 1000 a ni.

thil siam chhuah te .