A rilru a buai em em a, a 0 rilru a hah em em bawk a, a rilru a buai em em bawk a. Hmun
Distal humerus fractures hi orthopedics-ah chuan high-energy injury chi khat a ni tlangpui. Enkawlna harsatna chu anatomical structure complexity leh joint function siam that a ngaihna a ni. Orthopedic internal fixation field-a professional solution provider kan nih angin, distal humerus fracture-te tana injury mechanisms, AO classification, leh plate fixation strategies te chu clinical treatment dik tak thlawp turin in-depth analysis kan pe a ni.
Distal Humerus hi medial leh lateral column te a ni a, chung zingah chuan epicondyles leh condyles te pawh a tel a ni.
Distal humerus fractures hi direct trauma (eg, tlak) emaw indirect force (eg, twisting emaw muscle pull) emaw avanga lo awm a ni.
AO classification hian distal humerus fractures chu chi thum-ah a then a, chungte chu A , B , leh C .
Surgical treatment hian AO principles a zawm a: taksa peng tihtlem, stable fixation, leh a hmaa tihdamna.
Locking plate hian biomechanical stability sang zawk a pe a, a bik takin osteoporotic bone-ah chuan a tha zawk.
CZMedItech hian model pathum a pe a, chungte chu extraarticular (01.1107), lateral (5100-17), leh medial (5100-18) plate te an ni.
Distal humerus chu medial column leh lateral column-ah then a ni.
Medial column-ah hian humerus-a metaphysis medial part te, medial epicondyle te, leh medial condyle te, humerus trochlea te pawh a tel a ni.
Lateral column-ah chuan humerus-a metaphysis lateral part te, lateral epicondyle te, leh lateral condyle te, humerus-a capitulum te pawh a tel a ni.
Column pahnih inkarah hian anterior coronoid fossa leh posterior olecranon fossa te an awm a.
Elbow joint-a thil pawimawh tak a nih angin, distal humerus fractures hi 'direct trauma' (elbow-a fall landing ang chi) emaw 'indirect trauma' (twisting emaw throwing action ang chi) emaw avanga lo awm fo thin a ni.
Medial column-ah hian humerus-a metaphysis medial part te, medial epicondyle te, leh medial condyle te, humerus trochlea te pawh a tel a ni.
·In chhunga rotator muscle te a inzawm tlat .
·Elbow flexor muscle te chu a inzawm tlat a.
Pawn lam thiltihtheihna, traffic accident emaw, a san zawng atanga tlak emaw chuan comminuted fracture a thlen thei a, articular surface a huam thei bawk.
· Traffic accident a thleng thin .
·A san zawng atanga a tlak .
AO classification system ang chuan distal humerus fractures te hi a hnuaia mi ang hian categorize a ni a, enkawlna kawng thlan dan tur chu direct-in a nghawng a ni:
- A1: A fracture awlsam, articular involvement a awm lo.
- A2/A3: Metaphyseal fracture a tlak emaw, a inthlak emaw, angular deformities te tan attention mamawh.
Fracture line hian joint surface a huam a, mahse inthenna tluantling nei lovin; Joint congruency siam that leh nan hian anatomical reduction a ngai a ni.
- C1/C2: Intra-articular fracture awlsam tak tak, metaphyseal involvement nei.
- C3: Comminuted intra-articular fractures, enkawl harsa ber; Post-traumatic arthritis vei theihna tur tihtlem nan stable fixation neih a ngai a ni..
AO classification hian fracture nasat dan a tichiang a, fixation strength leh biological balance pahnih a awm theih nan plate thlan dan (eg, single vs. dual plates, locking screw designs) te kaihhruaina a pe bawk.
AO philosophy zawm: 'anatomical reduction, stable fixation, leh early functional exercise te.'
Pawn lam thiltihtheihna, traffic accident emaw, a san zawng atanga tlak emaw chuan comminuted fracture a thlen thei a, articular surface a huam thei bawk.
Type C fracture atan a tha. Medial (eg, anatomical locking plate) leh lateral (eg, parallel plate) lam pahnih atanga fixation hian 3D stability a pe a, postoperative rotational deformity a ti tlem bawk.
Type A leh partial type B fractures atan hman a ni. Distal humerus anatomy nena inmil pre-contoured plate te hian soft tissue dissection a ti tlem hle.
Percutaneous screw placement nen a inzawm chuan infection risk a tihziaawm bakah periosteal blood supply a humhim bawk.
Locking plate hian angular stability a pe a, a bik takin osteoporotic damlote tan a hlawkpui hle.
Anatomical reduction hian elbow joint mobility chu a tam thei ang berin a humhim a, nonunion emaw malunion emaw ang chi complication a tihziaawm bawk.
Fracture chi hrang hrang (eg, intercondylar ridge support plates) atana siam plate te hian force transmission a ti tha a, ruh damna a ti chak bawk.
Kan distal humerus locking plate series hi complex distal humeral fractures atan a bik takin siam a ni. Anatomical contouring, locking screw technology, leh specification tam tak hmangin clinical surgery atan fixation solution him, nghet leh flexible tak a pe a ni.
Model: 01.1107 a ni.
A rilru a buai em em a, a rilru a hah em em bawk a. 4–9 holes, 144–184 mm
Model: 5100-17 a ni.
A rilru a buai em em a, a rilru a hah em em bawk a. 4–12 holes, 86–190 mm
Model: 5100-18 a ni.
A rilru a buai em em a, a rilru a hah em em bawk a. 4–12 holes, 69–173 mm
Global Advanced Tibia Nailing Instruments Hming 2025 Top 6 Thil thar chhuah
A rilru a buai em em a, a rilru a hah em em bawk a, a rilru a buai em em bawk a.
A rilru a buai em em a, a rilru a hah em em bawk a. Distal Humerus Locking Plates ( May 2025 )
Distal Tibial Nail: Distal tibial fracture enkawlna kawnga hmasawnna ropui tak a ni.
Proximal Tibial Lateral Locking Plate-a clinical leh commercial synergy a awm dan chu a dik lo a ni.
Distal humerus fractures te plate fixation atana technical outline a awm.
Middle East-a TOP5 siamtute: Distal Humerus Locking Plates ( May 2025 )
Europe rama Top6 siamtute: Distal Humerus Locking Plates ( May 2025 )
Africa rama TOP7 siamtute: Distal Humerus Locking Plates ( May 2025 )
Oceania rama TOP8 siamtute: Distal Humerus Locking Plates ( May 2025 )