5100-04 thleng a ni
CZMEDITECH a ni
| A awm theih dan: | |
|---|---|
Product Description chungchang
Clavicle Hook Plate hian lateral clavicle fracture leh acromioclavicular joint injury pahnih fixation atan solution pakhat a pe a ni. He plate leh screw construct hian shoulder chu early rotational mobility a siam thei a ni.
• Lateral clavicle a tliak
• Acromioclavicular joint atanga inthlak danglamna
• Dynamic compression screw holes hian 3.5 mm cortex leh 4.0 mm cancellous bone screw a pawm a
• Anterolateral screw hole hian lateral clavicle-a screw fixation atan duhthlan tur dang a pe bawk
• Hook hian lateral clavicle fracture leh acromioclavicular joint dislocations pahnih tanpuina dang a pe bawk
• Plate 5、6、7、8、9 leh hole 10 nei a awm
• Left leh right plate-ah precontoured a ni
• Sumdawnna atana thianghlim (CP) titanium emaw 316L stainless steel emaw hmanga siam theih a ni
• Acromioclavicular ligament chhunga hook dah loh nan offset hook design

| Thil siam chhuah te | REF | A sawifiahna | Thickness a ni | Vang | Dung |
S-clavicle Locking Plate hmanga siam a ni (3.5 Locking Screw hmang rawh/ 3.5 Cortical Screw/ 1. A rilru a hah lutuk chuan a rilru a buai em em a. 4.0 Cancellous Screw hman theih a ni ) . |
5100-0401 ah biak theih a ni | 5 a awm L | 3 | 10.5 | 54 |
| 5100-0402 ah biak theih a ni | 6 holes a awm L | 3 | 10.5 | 67 | |
| 5100-0403 ah biak theih a ni | 7 holes a awm L | 3 | 10.5 | 81 | |
| 5100-0404 ah biak theih a ni | 8 holes a awm L | 3 | 10.5 | 94 | |
| 5100-0405 ah biak theih a ni | 9 holes a awm L | 3 | 10.5 | 107 | |
| 5100-0406 ah biak theih a ni | 10 a awm L | 3 | 10.5 | 131 | |
| 5100-0407 ah biak theih a ni | 5 a awm R | 3 | 10.5 | 54 | |
| 5100-0408 ah biak theih a ni | 6 a awm R | 3 | 10.5 | 67 | |
| 5100-0409 ah biak theih a ni | 7 holes a awm R | 3 | 10.5 | 81 | |
| 5100-0410 ah biak theih a ni | 8 holes a awm R | 3 | 10.5 | 94 | |
| 5100-0411 ah biak theih a ni | 9 holes a awm R | 3 | 10.5 | 107 | |
| 5100-0412 ah biak theih a ni | 10 a awm R | 3 | 10.5 | 131 |
Thlalak tak tak

Blog a ni
Clavicle, a nih loh leh collarbone hi ruh pawimawh tak a ni a, chu chuan shoulder blade leh chest bone a thlunzawm a ni. A ke ruh (shoulder) tihngheh kawngah hmun pawimawh tak a chang a, kut inthlakna hrang hrang a siam thei bawk. Mahse, clavicle fracture hi hliam a ni fo a, a bik takin infiammi leh mimal high-impact activity nei te zingah chuan a hliam fo thin. S-clavicle locking plate hi clavicle fracture enkawlna atana hman thin medical device a ni a, a dam chhungin stability leh support a pe a ni. He thuziak ah hian S-clavicle locking plate chu eng nge a nih, a hnathawh dan leh a hlawkna te kan chhui thui zawk ang.
S-clavicle locking plate chu titanium emaw stainless steel emaw atanga siam thir plate te tak te a ni a, chu chu surgery hmanga clavicle ruh tliak chungah dah a ni. Plate hian screw hole tam tak a nei a, chu chuan ruh chhungah screw dah theihna a siam a, a dam laiin ruh tliak chu a hmunah a vawng tlat a ni. Plate 'S' ang hian ruh dungah load leh tension chu inang tlangin a sem darh a, chu chuan clavicle chu a ti nghet thei a ni.
Surgery neih lai hian S-clavicle locking plate chu clavicle ruh chungah dah a ni a, plate kaltlangin screw dahin, a ruh tliak sir lehlamah ruh chhungah dah a ni. Plate hian ruh chu a ruh chu a dam laiin a hmunah a vawng tlat a, a dam chhungin stability leh support a pe a ni. Locking screws hian plate chu a che thei lo va, a tizau thei lo va, chu chuan ruh chu a dam laiin a awmna tur dik takah a awm reng tih a tichiang a ni. Plate hi low profile-a siam a ni a, soft tissue irritation hlauhawmna a ti tlem a, rang zawk leh nuam zawka dam leh theihna a siam bawk.
Clavicle fracture enkawlna atana S-clavicle locking plate hman hian hlawkna engemaw zat a nei a, chung zingah chuan:
S-clavicle locking plate hian ruh tliak chu stability tha zawk a pe a, displacement risk a ti tlem a, damna tha zawk a siam bawk.
S-clavicle locking plate hman hian a ruh tliakna hmun chu stability leh support nghal a pe a, a damna ti chak thei a ni.
S-clavicle locking plate-a locking screw hman te hian implant migration, screw loosening, leh infection ang chi harsatna awm thei te a ti tlem a ni.
S-clavicle locking plate design hniam tak hian soft tissue irritation hlauhawmna a ti tlem a, nuam zawkin a dam leh thei bawk.
S-clavicle locking plate hi clavicle fracture chi hrang hrang awm theihna tura siam a ni a, open leh closed reduction surgery-ah pawh hman theih a ni.
Damlo clavicle fracture nei, surgical intervention mamawh te chu S-clavicle locking plate hmanna tur candidate tha tak an ni. He device hi puitling leh naupang tan pawh a tha a, displaced emaw comminuted fractures emaw a awm chuan hman theih a ni. Damlo, a hmaa clavicle surgery nei tawh emaw, ruh damna tichhe thei damdawi lama harsatna awm tawh emaw chu he procedure atana candidate tling an ni lo mai thei.
S-clavicle locking plate procedure hi general anesthesia hmanga tih a ni tlangpui a, minute 60-90 vel a ngai a ni. Surgeon chuan clavicle tliak chungah incision a siam ang a, ruh tliak te chu uluk takin a dah leh ang. Chumi hnuah chuan S-clavicle locking plate chu ruh chungah dah a ni ang a, chu chu plate kaltlangin leh ruh tliak sir lehlamah screw dah a ni ang. Plate leh screw te chu a hmunah nghet taka dah a nih chuan incision chu khar a ni ang a, damlo chu recovery area-ah sawn a ni ang a, damdawi in atanga chhuah hmain darkar engemawzat enkawl a ni ang.
Operation hnuah chuan damlote chuan ruh a dam laiin kut thlawp tur leh che vel tihtlem nan sling an bun a ngai tlangpui ang. Physical therapy pawh hi shoulder leh arm-a range of motion leh chakna neih leh theihna tura puih theih a ni bawk. Dam leh hun chhung hi a ruh nasat dan leh damlo hriselna zawng zawng a zirin a inang lo a, mahse damlo tam zawk chu operation an neih hnu thla thum atanga thla ruk chhungin an hnathawh dan pangngaiah an kir leh thei a ni.
Surgery dang ang bawkin S-clavicle locking plate hman hian hlauhawmna leh harsatna awm thei a awm a ni. Chung zingah chuan:
Kaichhawng
Implant atanga inthlak danglamna
Screw a lo chhuak emaw a chhe emaw
Nerve emaw thisen kalna kawng emaw a chhiat
Implant atanga allergy a awm thin
Damlote chuan operation neih an tum hmain an surgeon nen he procedure hian a hlauhawmna leh a hlawkna an sawiho tur a ni.
S-clavicle locking plate hi medical device a ni a, clavicle fracture enkawlna atan hman a ni a, a dam laiin stability leh support a pe a ni. Plate danglam bik 'S' shape hian ruh dungah load leh tension chu a sem darh a, stability a ti tha a, damna tha zawk a siam bawk. S-clavicle locking plate hman hian hlawkna engemaw zat a pe a, chung zingah chuan stability tihchangtlun, dam leh hun rei zawk, leh harsatna awm theihna a tlem zawk. Mahse, surgery dang ang bawkin, he device hman hian hlauhawmna leh harsatna awm thei a awm a ni. Damlote chuan an surgeon nen a hlauhawmna leh hlawkna an sawiho tur a ni a, operation neih an tum hmain an duhthlan turte uluk takin an ngaihtuah hmasa tur a ni.
S-clavicle locking plate surgery hian eng chen nge hun a duh?
Surgery hi minute 60-90 vel a ni tlangpui.
S-clavicle locking plate surgery atanga dam leh theih nan eng chen nge a mamawh?
Dam leh hun chhung hi a ruh nasat dan leh damlo hriselna zawng zawng a zirin a inang lo a, mahse damlo tam zawk chu operation an neih hnu thla thum atanga thla ruk chhungin an hnathawh dan pangngaiah an kir leh thei a ni.
Naupangte tan S-clavicle locking plate hman theih a ni em?
Ni e, device hi puitling leh naupang tan pawh a tha hle.
S-clavicle locking plate surgery-ah hian hlauhawmna a awm em?
Surgery dang ang bawkin S-clavicle locking plate hman hian hlauhawmna leh harsatna awm thei a awm a ni. Chung zingah chuan infection, implant migration, screw loosening emaw breakage emaw, nerve emaw blood vessel tihchhiat, implant allergic reaction te pawh a tel thei.
Ruh damna tichhe thei damdawi lama harsatna awm tawh ka neih chuan S-clavicle locking plate surgery ka nei thei ang em?
Thil siam chhuah te