5100-29 thleng a ni
CZMEDITECH
1 piece a ni
Titanium a ni
OEM leh ODM service hrang hrang a awm
CE / ISO :9001/ ISO 13485. A rilru a hah lutuk chuan a rilru a buai em em a
Technical support, product training, surgical guidance, leh hun rei tak chhunga hralh hnua service pek te a ni
FedEx / DHL / TNT / EMS / etc. te hi a ni
Distal tibial fractures leh lateral column inrawlhna (AO/OTA 43-A, B, C) a awm bawk.
| A awm theih dan: | |
|---|---|
Product Description chungchang
3.5 mm Distal Lateral Tibial Locking plate hi CZMEDITECH Locking Compression Plate (LCP®) System-a tel an ni a, Screw khâr technology chu plating technique pangngai nen an inzawm khawm a ni. Heng anatomically shaped 3.5mm plate te hi stainless steel emaw titanium alloy emaw hmanga siam niin 5-13 hole configuration a awm a ni.
Distal Screw khârte hian articular surface tan support a pe a
Volkmann-a triangle leh Chaput fragment te chu targeted locking a ni
Anatomically a siam a ni
Shaft holes hian 3.5 mm Screw khârte , 3.5 mm cortex screw leh 4.0 mm cancellous screw te a pawm a ni
Lu khur hian 3.5 mm Screw khârte , 2.7 mm leh 3.5 mm cortex screw leh 4.0 mm cancellous screw te a pawm a ni
60o twist in shaft chu distal tibia anatomy atan contoured a ni
Submuscular insertion atan tapered tip a awm
316L stainless steel emaw titanium alloy emaw hmanga siam a ni
Shaft chhunga 60°twist chu distal tibia anatomy atan contoured a ni: plate contouring tlem zawk a ngai.
Anatomic reduction: Anatomic plate profile leh joint bula parallel screw pali chuan metaphysis chu diaphysis-a tihtlem a pui a, chu chuan alignment leh functional anatomy a siam leh thei a ni. Intra-articular fractures tan chuan joint congruency siam that nan anatomic reduction tih ngei ngei tur a ni.
Stable fixation: Conventional leh Screw khârte te inzawmkhawm hian ruh density eng pawh nise fixation tha ber a pe a ni.
Thisen supply humhalh: Limited-contact plate design hian plate-to-bone contact a ti tlem a, periosteal blood supply humhalh nan a pui bawk.
3.5 mm LCP Anterolateral Distal Tibia Plate hi distal tibia-a fracture, osteotomies, leh nounionions atan hman a ni a, a bik takin osteopenic bone-ah chuan hman a ni.

| Thil siam chhuah te | REF | A sawifiahna | Thickness a ni | Vang | Dung |
A hnaih ber Lateral Tibial Locking plate -II (3.5 Screw khâr /3.5 Cortical Screw hmang rawh) |
5100-2601 ah zawh theih a ni | 5 a awm L | 4.2 | 12.5 | 97 |
| 5100-2602 ah zawh theih a ni | 7 holes a awm L | 4.2 | 12.5 | 124 | |
| 5100-2603 ah zawh theih a ni | 9 holes a awm L | 4.2 | 12.5 | 151 | |
| 5100-2604 ah zawh theih a ni | 11 khur a ni L | 4.2 | 12.5 | 178 | |
| 5100-2605 ah zawh theih a ni | 13 a awm L | 4.2 | 12.5 | 205 | |
| 5100-2606 ah zawh theih a ni | 5 a awm R | 4.2 | 12.5 | 97 | |
| 5100-2607 ah zawh theih a ni | 7 holes a awm R | 4.2 | 12.5 | 124 | |
| 5100-2608 ah zawh theih a ni | 9 holes a awm R | 4.2 | 12.5 | 151 | |
| 5100-2609 ah zawh theih a ni | 11 khur a ni R | 4.2 | 12.5 | 178 | |
| 5100-2610 ah zawh theih a ni | 13 a awm R | 4.2 | 12.5 | 205 |
Thlalak tak tak

Blog a ni
Distal lateral tibial Locking plate hi damdawi hmanrua a ni a, distal tibia ruh tliak te fixation atan hman a ni. He device hian ruh tliak chu stable fixation a pe a, damlo chu a hmaa mobilization a siamsak bawk. He thuziak ah hian distal lateral tibial Locking plate chungchang chipchiar takin kan sawi dawn a, a design, a indications, surgical technique, complications, leh outcomes te pawh kan sawi dawn a ni.
Distal lateral tibial Locking plate hi plate chi khat a ni a, distal tibia ruh tliak enkawlna atana hman thin a ni. He plate hi ruh chi hrang hrangte chu stable fixation pe thei tura siam a ni a, damlo chu a hmaa mobilization theih a ni. Plate hi titanium a siam a ni a, screw dahna tur khur tam tak a nei bawk.
Distal lateral tibial Locking plate hian design danglam tak a nei a, chu chuan distal tibia chu stable fixation a siam thei a ni. Plate hian proximal end leh distal end a nei a, tibia shape nena inmil turin contoured a ni. Plate hian screw hole tam tak a nei a, screw te hi locking fashion-in an dah lut bawk. Screw-te locking mechanism hian screw-te chu a hnungtawlh loh nan a veng a, ruh chi hrang hrangte chu stable fixation a pe bawk.
Distal lateral tibial Locking plate hi distal tibia ruh tliak enkawlna atan hman a ni. Plate hi a bik takin, hmanlai dan hmanga tihngheh harsa tak, ruh tliak enkawlna atan a tangkai hle. Hei hian fracture comminuted emaw fragment tam tak nei emaw a huam a ni. Plate hi ankle joint bula awm fracture enkawlna atan pawh a tangkai hle.
Distal lateral tibial Locking plate surgical technique ah hian ruh tliak te chu open reduction leh internal fixation a ni. Plate hi tibia pianzia nena inmil turin contoured a ni a, ruh lateral aspect-ah dah a ni. Screw te chu locking fashion-in an dah a, plate chu ruh lamah an nghet tlat a ni.
Distal lateral tibial Locking plate hman avanga harsatna awmte chu infection, nonunion, malunion, leh hardware failure te a ni. Surgical incision awmna hmunah emaw, hardware chhehvelah emaw infection a awm thei. Nonunion leh malunion a awm thei a, ruh chi hrang hrang a dam tha lo a nih chuan. Hardware failure hi screw emaw plate emaw a chhe emaw, a back out emaw a nih chuan a awm thei.
Distal lateral tibial Locking plate hman hi distal tibia ruh tliak enkawlna atan a tangkai hle tih hmuhchhuah a ni. Plate hian ruh chi hrang hrangte chu stable fixation a pe a, damlo chu a hmaa mobilization a siamsak bawk. Zirna hrang hrangah chuan plate hman hian union rates sang tak leh clinical outcome tha tak a thlen tih hmuhchhuah a ni.
Distal lateral tibial Locking plate hi distal tibia ruh tliak enkawlna atana hmanraw tangkai tak a ni. Plate hian ruh chi hrang hrangte chu stable fixation a pe a, damlo chu a hmaa mobilization a siamsak bawk. Mahse, he device hian harsatna a thlen theihna a nei a, damlo uluk taka thlan leh surgical technique hi a tha ber tur atan a pawimawh hle.
Distal lateral tibial Locking plate tih hi eng nge ni ? Distal lateral tibial Locking plate hi damdawi hmanrua a ni a, distal tibia ruh tliak te fixation na atan hman a ni.
Engtin nge distal lateral tibial Locking plate hian hna a thawh? Distal lateral tibial Locking plate hian ruh tliak chu stable fixation a pe a, damlo chu a hmaa mobilization a siamsak bawk. Plate hi titanium a siam a ni a, screw dahna tur khur tam tak a nei bawk.
Distal lateral tibial Locking plate awm theihna tur indication te chu engte nge ni ? Distal lateral tibial Locking plate hi distal tibia ruh tliak enkawlna atan hman a ni. A bik takin, hmanlai dan hmanga stabilize harsa, comminuted fracture emaw, ankle joint bula fracture emaw te tan a tangkai hle.
Distal lateral tibial Locking plate hman avanga harsatna awm thei te chu engte nge ni? Distal lateral tibial Locking plate hman avanga harsatna awmte chu infection, nonunion, malunion, leh hardware failure te a ni. Damlo uluk taka thlan leh surgical technique hi optimal outcome atan a pawimawh hle.
Distal lateral tibial Locking plate hman hian eng nge a chhuah ? Zirna hrang hrangah chuan distal lateral tibial Locking plate hman hian union rates sang tak leh clinical outcome tha tak a thlen tih hmuhchhuah a ni. Mahse, mimal outcome chu damlo bik leh fracture characteristics a zirin a danglam thei.