Zawhna i nei em?        +86- 18112515727 ah zawhfiah theih a ni       hla@orthopaedic-china.com ah hian a awm a
Please Choose Your Language
Hetah hian i awm: In » Thil siam chhuah te » Locking plate » Ruh them lian » Distal Femoral Locking plate

loading a ni

Share to:
facebook ah in share theih a ni
twitter hmanga share theih a ni
line sharing tih a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
whatsapp a insem theihna tur a ni
sharethih hi share theih a ni

A rilru a buai em em a, a rilru a hah em em bawk a. Locking plate

  • 5100-35 thleng a ni

  • CZMEDITECH

A awm theih dan:

Product Description chungchang

Distal Femoral Locking plate hi eng nge ni ?

LCP Distal Femur Plates te hi LCP System hmanga siam a ni.

Plate shaft portion-ah hian Combi holes a awm a, head-ah hian threaded holes a awm bawk. Plate te pianzia hi Distal Femur LISS plate design atanga siam a ni. Plate te hi veilam leh dinglam femur pahnih tan hole 5, 7, 9, 11 leh 13 neiin a awm a.

Ruh them lian Plate fixation atan hian LCP instrument leh screw te hman a ni.



Screws hmang rawh

LCP Distal Femur Plates te hi a hnuaia screw te nen hian a inmil thei a ni.

– 5.0 mm a ni Screw khârte

– 5.0 mm Screw khârte , mahni in laih theih

– 5.0 mm Cannulated hmanga siam Screw khârte

– 5.0 mm Cannulated Conical Screw hmanga siam a ni

– 4.5 mm Cortex Screw hmanga siam a ni

– 4.5 mm Cannulated Screw hmanga siam a ni


Plate lu chhungah threaded holes a awm

Round locking holes hian 5.0 mm Screw khârte leh 4.5 mm Cortex Screws a pawm a ni.Preshaped plate Preshaped, low-profile plate hian soft tissue-a harsatna awmte a ti tlem a, plate contouring a ngai tawh lo.

Plate shaft-a LCP Combi holes Combi hole hian standard 4.5 mm Cortex Screws, 5.0 mm Screw khârte emaw a pahnih inzawmkhawm hmangin internal plate fixation a phal a, chu chuan intraoperative technique flexible zawk a siam thei a ni.

Angular stability Screw loosening bakah primary leh secondary loss of reduction a veng a, functional mobilization hmasa ber a siam thei bawk.

Rounded plate tip Tapered, rounded plate tip hian surgical technique a ti awlsam hle.

Indication te chu

Distal Femoral Locking plates hi multifragmentary distal femur fracture te buttressing nan hman a ni a, chung zingah chuan: supracondylar, intra-articular leh extra-articular te pawh a tel

condylar, periprosthetic atanga chhuak (periprosthetic fractures) te; ruh pangngai emaw, ruh hring (osteopenic bone)-a ruh tliak; nonunion leh malunion te; leh femur-a osteotomies te pawh a awm bawk.

A rilru a buai em em a, a rilru a hah em em bawk a. Locking plate

specification hrang hrang a awm

Thil siam chhuah te REF A sawifiahna Thickness a ni Vang Dung

A rilru a buai em em a, a rilru a hah em em bawk a. Locking plate 

(5.0 Screw khâr /4.5 Cortical Screw hmang rawh)

5100-3501 ah zawh theih a ni 5 a awm L 6.0 17.5 164
5100-3502 ah zawh theih a ni 7 holes a awm L 6.0 17.5 204
5100-3503 ah zawh theih a ni 9 holes a awm L 6.0 17.5 244
5100-3504 ah zawh theih a ni 11 khur a ni L 6.0 17.5 284
5100-3505 ah biak theih a ni 13 a awm L 6.0 17.5 324
5100-3506 ah zawh theih a ni 5 a awm R 6.0 17.5 164
5100-3507 ah biak theih a ni 7 holes a awm R 6.0 17.5 204
5100-3508 ah biak theih a ni 9 holes a awm R 6.0 17.5 244
5100-3509 ah biak theih a ni 11 khur a ni R 6.0 17.5 284
5100-3510 ah zawh theih a ni 13 a awm R 6.0 17.5 324


Thlalak tak tak

A rilru a buai em em a, a rilru a hah em em bawk a. Locking plate

Blog a ni

Distal Femoral Locking plate : Kaihhruaina kimchang tak

Distal femoral Locking plate hi damdawi hmanrua a ni a, distal femur-a ruh tliak leh hliam dangte enkawlna atana hman a ni. He thuziak hian distal femoral Locking plate chungchang kaihhruaina kimchang tak a pe ang a, a design leh hman dan atanga a hlawkna leh a hlauhawmna thlengin a huam vek ang.

Distal Femoral Locking plate tih hi eng nge ni ?

Distal femoral Locking plate hi damdawi hmanrua a ni a, chu chu distal femur-a ruh tliak leh hliam dangte enkawlna atana hman a ni a, chu chu khup ruh hnuai lam, khup ruh nena inzawm a ni. Plate hi titanium emaw biocompatible material dang emaw hmanga siam a ni a, ruh tliak chu a ti nghet thei tur leh ruh tihdamna tur atana siam a ni.

Engtin Nge Distal Femoral Locking plate hi A Hnathawh?

Distal femoral Locking plate hian a ruh tliak chu rigid internal fixation pein hna a thawk a, chu chuan a hmaa mobilization leh rang zawka dam theihna a siam a ni. Plate hi ruh chungah screw hmangin an inzawm a, chu chu plate chhunga khur kaltlangin ruh chhungah dah a ni.

Distal Femoral Locking plate hman hian eng hlawkna nge a neih ?

Distal femoral Locking plate hman hlawkna chu:

  • Damna hun rang zawk

  • Harsatna awm theihna a ti tlem

  • Fracture stability a ti sang

  • Range of motion tihchangtlun a ni

Distal Femoral Locking plate hman hian eng hlauhawmna nge a neih ?

Distal femoral Locking plate hman a hlauhawmna chu:

  • Kaichhawng

  • Hardware a chhiat avangin

  • Screw a lo chhuak emaw a chhe emaw

  • Nerve emaw thisen kalna kawng emaw a chhiat

Engtin nge Distal Femoral Locking plate hi an dah luh?

Distal femoral Locking plate insertion hi general anesthesia hmanga tih a ni tlangpui. Hetiang tih danah hian ruh tliakna hmun chungah incision siamin ruh chu a lang chhuak thin. Chumi hnuah chuan plate chu fracture chungah dahin screw hmangin ruh-ah an nghet tlat a ni.

Distal Femoral Locking plate dah hnua Recovery Process hi eng ang nge ni?

Distal femoral Locking plate dah hnua dam lehna kawngah hian a tlangpuiin immobilization hun chhung a awm a, chu chu physical therapy hmanga enkawl a ni. Immobilization period rei zawng leh physical therapy hun chhung chu a ruh tliak nasat dan leh damlo pakhat zel a zirin a innghat ang.

Distal Femoral Locking plate hman Hlawhtlinna Rate chu engzat nge ni ?

Distal femoral Locking plate hman hlawhtlinna hi a fracture bik leh damlo pakhat zel a zirin a inang lo. Mahse, zirchianna hrang hrangah chuan distal femoral Locking plate hman hian fracture healing hlawhtling tak a thlen thei a, damlote outcome pawh a ti tha thei tih hmuhchhuah a ni.

Tawpna

Thutawp atan chuan distal femoral Locking plate hi damdawi hmanraw hlu tak a ni a, distal femur-a ruh tliak leh hliam dangte enkawlna atana hman a ni. A hlawkna chu a dam rei zawk a, harsatna a thlen theihna a ti tlem a, a ruh tliak chu a nghet zawk a, a chetna pawh a ti tha zawk bawk. Mahse, damdawi lam thil dang ang bawkin a hmannaah hian hlauhawm leh harsatna a awm thei a ni. Damlote tan chuan distal femoral Locking plate hman a hlauhawmna leh hlawkna te chu an healthcare provider nen sawiho a pawimawh a, chu chu an tan enkawlna tha ber a ni em tih hriat a pawimawh hle.

FAQs te

  1. Distal femoral Locking plate insertion atanga dam leh theih nan eng chen nge a ngaih ?

    • Recovery time hi fracture nasat dan leh damlo pakhat zel a zirin a inang lo a, mahse a tlangpuiin immobilization hun chhung a awm a, chu chu physical therapy hmanga enkawl a ni.

  2. Distal femoral Locking plate hman hian eng hlauhawmna nge a neih ?

    • A hlauhawmna chu infection, hardware failure, screw loose emaw breakage emaw, nerve emaw blood vessel chhiatna emaw a ni.

  3. Engtin nge distal femoral Locking plate hi an dah luh?

    • Chutianga tih dan tur chu a ruh tliakna hmun chungah incision siamin, screw hmangin plate chu ruh lamah an nghet tlat a ni.


Hma chiah: 
Dawtchiah: 

CZMEDITECH A anpui che

Fracture hrang hrang tan kan solution range kimchang zawng rawh.
 
* Spine categroies lian zawng zawng khuh vek tur ;
* Quality leh delivery time lamah customer te thlamuan fo thin ;
* High cost performance kan zawm a,dealer ten profit space an neih theih nan.
Min rawn biak theih reng e

I CZMEDITECH Orthopaedic Expert te zawt rawh

I orthopaedic mamawhna atana i mamawh quality leh value, a hun taka leh budget chhunga pe turin pitfalls pumpelh turin kan pui che a ni.
Changzhou-a Meditech Technology Co., Ltd. chuan a rawn ti a.
Thil siam chhuah te
Thawhna
OEM/ODM
Tunah hian zawt rawh
© COPYRIGHT 2026 CHANGZHOU MEDITECH TECHNOLOGY CO., LTD., a hnuaia mi ang hian a hlawhtling hle. DIKNA ENGKIM A NI.