M-24-ah a awm
CZMEDITECH a ni
damdawi lam stainless steel hmanga siam a ni
CE/ISO:9001/ISO13485 a ni
| A awm theih dan: | |
|---|---|
Product Description chungchang
Hollow drill hi intramedullary nailing leh endoscopic surgery atan hman a ni ber. Ergonomic shape tha tak, temperature sang leh autoclave sterilization, ri hniam, speed chak leh service life rei tak a ni. Main unit hi adapter hrang hrangah connect theih a ni a, chu chu thlak danglam zel theih a ni a, hman a awlsam bawk.
Bone tunnel alignment control theihna turin hollow drill bit hman a ni. Bone tunnel emaw screw holes emaw chu guidewire te tak te hmanga siam a ngai a ni. Surgeon chuan guide wire chu a awmna tur dik takah a awm tih a hriat chuan guide wire-ah chuan khur an siam a, chu chuan khur a siam a ni. A tul lova ruh tihchhiat loh nan guide wire chu a tul angin dah theih a ni.
A sawifiahna
|
SPECIFICATION THIL AWM DAN
|
STANDARD THIL AWM DAN THIL THAWN THIN
|
||
|
Input Voltage a ni
|
110V-220V inkar a ni
|
Drill handpiece a ni
|
1pc a ni
|
|
Battery voltage a ni
|
14.4V a ni
|
charger a ni
|
1pc a ni
|
|
Battery a chak zawng a ni
|
Duh zawk thlang
|
Battery
|
2pcs a ni
|
|
Drill speed a ni
|
1200rpm a ni
|
Aseptic battery transfer ring a ni
|
2pcs a ni
|
|
Cannulated diameter a ni
|
4.5mm a ni
|
chahbi
|
1pc a ni
|
|
Drill chuck clamping diameter a ni
|
0.6-8mm inkar a ni
|
Aluminium a siam a ni
|
1pc a ni
|
Features & Hlawkna te

Thlalak tak tak

Blog a ni
Cannulated bone drills hi orthopaedic surgery-a hmanraw pawimawh tak a ni. Thil chi hrang hrang atan ruh chhunga khur chiang tak siam nan an hmang thin. Cannulated drills hi a danglam bik a, hollow center a nei a, hei hian K-wire, guide wire leh implant dangte dah theihna a siam a ni. Heng drills te hi surgeon toolbox-a thil pawimawh tak a ni a, chu chu fracture fixation, arthroscopy, leh spinal surgery te ang chi procedure hrang hrang atan a ni. He thuziak hian cannulated bone drill hman thatna, hman dan leh hmanraw hrang hrangte thui takin a sawi a ni.
Precision: Cannulated bone drills hian ruh chhunga khur siam hunah precision a pe a, implant dah dik zawk theih a ni.
Versatility: Drill-a hollow center-ah hian guide wire, K-wire leh implant dangte dah theih a ni a, hei vang hian orthopaedic surgery atana hmanraw tangkai tak a ni.
Thermal injury hlauhawmna tihtlem: Cannulated drills hian drill bit chhehvela coolant flow tha zawk a siam avangin drilling laiin thermal injury hlauhawmna a ti tlem a ni.
Soft tissue chhiatna tlem: Cannulated drills hian entry point te zawk a siam avangin soft tissue chhiatna a ti tlem a, hei hian damna hun a tikhawtlai zawk.
Fracture fixation: Cannulated bone drills hmangin ruh chhunga khur siam nan ruh ruh fixation procedure atan hman a ni.
Arthroscopy: Arthroscopic procedure-ah te hman a ni a, instrument leh implant te tan khur siam nan an hmang thin.
Spinal surgery: Spinal surgery-ah hian cannulated drills hmangin screw leh spinal implant dang dahna tur khur siam a ni.
Orthopedic oncology: Cannulated drills hi orthopedic oncology procedure-ah pawh hman a ni a, ruh biopsies leh bone grafting procedure-a khur siam nan hman a ni bawk.
Drill bit dik thlang rawh: Drill bit size chu implant dah tur size nen a inmil tur a ni.
Drill bit dah rawh: Drill bit chu drill cannula chhungah dah la, a hmunah lock rawh.
Drill the hole: Thermal injury tihziaawmna turin coolant flow tling tak enfiah chungin i duh thuk thlengin drill rawh.
Implant dah: Hole chu drill a nih hnuah drill bit hollow center kaltlangin implant chu dah theih a ni.
A tawi zawngin, cannulated bone drills hi orthopaedic surgery-a hmanraw pawimawh tak a ni. Anni hian precision, versatility, leh thermal injury leh soft tissue tihchhiat theihna a ti tlem hle. Heng drill te hian fracture fixation, arthroscopy, spinal surgery, leh orthopedic oncology-ah te hmanna tam tak a nei a ni. Cannulated bone drill hman dan tur dik tak zawm hi surgical outcome tha ber neih theih nan a pawimawh hle.
Cannulated bone drills hi standard bone drills aiin a man a to zawk em?
Ni e, cannulated bone drills hi a tlangpuiin a design danglam bik leh a versatility avang hian a man a to zawk.
Cannulated bone drill hman hian natna kai theihna a awm em?
Surgery tih hian natna kai theihna a awm fo thin. Mahse, sterilization technique dik tak chuan hri kai theihna a ti tlem thei a ni.
Cannulated bone drills hi naupang ruh lam surgery-ah hman theih a ni em?
Ni e, cannulated bone drills hi naupang ruh lam surgery-ah hman theih a ni. Mahse, ruh lian zel tihchhiat loh nan drill bit size dik tak hman a nih theih nan fimkhur a ngai a ni.
Cannulated bone drill bit diameter tlangpui chu engzat nge ni?
Cannulated bone drill bit diameter hi 1.5mm atanga 10mm inkar a ni a, hei hi procedure tih tur chi leh implant dah tur size a zirin a ni.
Engtin nge cannulated bone drill hian thermal injury hlauhawmna a tihziaawm?
Cannulated bone drill-a hollow center hian drill bit chhehvelah coolant a kal tha zawk a, ruh leh a chhehvel tissue-a thermal injury awm theihna a ti tlem a ni.
A pum puiin, cannulated bone drills hi orthopaedic surgery-a hmanraw pawimawh tak a ni. Anni hian precision, versatility, leh hliam hlauhawmna tihziaawmna an pe a, chu chuan surgeon toolbox-a thil pawimawh tak a ni. Cannulated bone drill hman dan tur dik tak zawm hi surgical outcome tha ber neih theih nan a pawimawh hle a, standard bone drill aiin a man a to zawk thei a, mahse an design danglam bik leh an hman tangkai theihna hian investment a phu hle.
Thil siam chhuah te