2200-05 chhung a ni
CZMEDITECH a ni
| A awm theih dan: | |
|---|---|
Product Video a ni
Titanium Mesh Cage Instrument Set ah hian a tlangpuiin spinal fusion surgery neih chhunga titanium mesh cage implant nana surgical instrument leh hmanrua mamawh te a tel thin. Set-a instrument bik awmte chu siamtu a zirin a danglam thei a, mahse:
Cage insertion tools: Hengte hi titanium mesh cage chu intervertebral space-a dah luh theihna tura siam, specialized instruments an ni.
Bone grafting instruments: Heng hmanrua te hi damlo taksa atanga ruh lakkhawmna atan emaw, ruh bank atanga ruh lakkhawm nan te, ruh grafting chu cage chhunga dah tur atana buatsaih nan te hman a ni.
Discectomy instruments: Heng instruments hmang hian damlo ruh atanga disc chhia emaw, chhe tawh emaw chu paih chhuah a ni a, titanium mesh cage atan hmun a siam a ni.
Plate leh screw driver: Hengte hi cage hmuna vawn tlat screw leh plate dahna atana hmanraw bik an ni.
Retractors: Retractors hi surgery hmun hawn reng nan leh cage dahna tur intervertebral space-a luh theihna tur atan hman a ni.
Drill bits: Drill bits hi screw insertion atana spinal vertebrae buatsaihna set-ah hian dah tel theih a ni.
Inserter handles: Inserter handle hmang hian screw leh implant dangte chu a hmuna awm tura kaihhruaina atan hman a ni.
Measuring and sizing instruments: Heng instruments te hian surgeon chu titanium mesh cage leh implant dangte size leh dahna tur dik tak a hriat theih nan a pui thin.
Titanium Mesh Cage Instrument Set-a hmanraw bikte chu surgical technique bik leh surgeon duh dan azirin a danglam thei tih hriat a pawimawh hle. Set-ah hian sterile packaging leh surgical procedure atana thil tul dangte pawh a tel thei bawk.
Features & Hlawkna te

A sawifiahna
|
AIH.
|
PER
|
Hrilhfiahna
|
Qty.
|
|
1
|
2200-0501 ah zawh theih a ni
|
Cage Stand a ni
|
1
|
|
2
|
2200-0502 ah zawh theih a ni
|
Pressure chu 6mm a ni
|
1
|
|
3
|
2200-0503 ah zawh theih a ni
|
Pressure chu 18mm a ni
|
1
|
|
4
|
2200-0504 ah zawh theih a ni
|
Pusher Dinglam a ni
|
1
|
|
5
|
2200-0505 ah zawh theih a ni
|
Osteotribe a ni
|
1
|
|
6
|
2200-0506 ah zawh theih a ni
|
Pressure chu 12mm a ni
|
1
|
|
7
|
2200-0507 ah zawh theih a ni
|
Pusher Curved a ni
|
1
|
|
8
|
2200-0508 ah zawh theih a ni
|
Cage Cutter a ni
|
1
|
|
9
|
2200-0509 ah zawh theih a ni
|
Cage-a vawn Forcep
|
1
|
|
10
|
2200-0510 ah zawh theih a ni
|
Implant tehna 10/12mm a ni
|
1
|
|
11
|
2200-0511 ah zawh theih a ni
|
Implant tehna 16/18mm a ni
|
1
|
|
12
|
2200-0512 ah zawh theih a ni
|
Implant tehna 22/25mm a ni
|
1
|
|
13
|
2200-0513 ah zawh theih a ni
|
Aluminium Box a ni
|
1
|
Thlalak tak tak

Blog a ni
Spinal fusion procedure atana orthopedic surgery-ah titanium mesh cage hman hi a lar chho zel a ni. Heng cage te hian graft chu mechanical support a pe a, ruh tissue thar ingrowth theihna turin bone fusion a tichak bawk. He thuziak ah hian spinal fusion surgery-a titanium mesh cage instrument set hman thatna, hman dan leh ngaihtuah turte kan zirchiang dawn a ni.
Spinal fusion surgery-a titanium mesh cage hman a thatna ber chu a structural integrity a ni. Heng cage te hi graft chu rigid support pe thei tura siam a ni a, graft chim emaw, a chhuah emaw theihna a ti tlem a ni. Titanium chakna hian he thil atan hian thil tha tak a ni a, taksain a chunga chakna a siam chu a tuar thei a ni.
Titanium mesh cage hman thatna dang chu a biocompatibility a ni. Titanium hi biologically inert material a ni a, taksa atanga immune response a siam lo tihna a ni. Hei hian surgical implant-a hman tur thil tha tak a ni a, a chhan chu rejection emaw allergic reaction emaw a awm theihna a ti tlem a ni.
Titanium mesh cage hi radiolucent a ni a, chu chu imaging technology X-ray emaw CT scan emaw a tibuai lo tihna a ni. Hei hian implant leh a chhehvel ruh tissue te chiang taka hmuh theihna a siam a, fusion progression leh implant stability tehnaah a pui bawk.
Titanium mesh cage hmanna ber chu spinal fusion surgery-ah a ni. Heng cage te hi graft-a mechanical support pekna atan hman a ni a, chu chuan ruh tissue thar siam theihna leh a nghawng spinal segment te fusion theihna a siamsak a ni. A tlangpuiin bone graft material leh pedicle screw te nen hman dun a ni a, hei hian a nghawng spinal segment chu stability leh support a pe thei a ni.
Titanium mesh cage hi reconstructive surgery-ah pawh ruh tissue chhia siamthat emaw thlak danglam emaw nan hman theih a ni. A bik takin ruh grafting hmanlai hmanraw hman tangkai lohna hmunah te, ruh chhiatna lian tak tak emaw, non-union emaw a awm chuan an tangkai hle.
Spinal fusion surgery-a hman tur implant thlan hunah titanium mesh cage design hi ngaihtuah tur pawimawh tak a ni. Cage hi a size dik taka siam tur a ni a, chu chu affected spinal segment nena inmil tur a ni a, graft chu a support tha tawk tur a ni. Design hian ruh tissue thar ingrowth theihna a siam bawk tur a ni a, imaging atan radiolucency tling tak a awm tur a ni bawk.
Mesh cage siamna atana hman titanium quality hi ngaihtuah tur dang a ni. Implant hi medical-grade titanium atanga siam tur a ni a, hei hi surgical implant-a hman tur bik atana siam a ni. Material chu biocompatible a ni tur a ni a, regulatory standard kaihhnawih zawng zawng a tlin tur a ni.
Titanium mesh cage dah luh huna surgical technique hman thin pawh a pawimawh hle. Implant chu a awmna tur dik takah dah tur a ni a, chu chuan graft chu a thlawp thei ang a, a chhehvel tissue emaw structure emaw a tihchhiat loh nan fimkhur tur a ni. Intraoperative imaging hman hian implant dah dikna kawngah a pui thei a ni.
Spinal fusion surgery-a titanium mesh cage instrument set hman hian hlawkna engemaw zat a nei a, chung zingah chuan structural integrity, biocompatibility, leh radiolucency te pawh a tel. Heng cage te hi ruh tissue chhia siamthat emaw thlak danglam emaw nan reconstructive surgery-ah pawh a tangkai hle. Titanium mesh cage hman dan tur ngaihtuah hian implant design, material quality, leh surgical technique te ngaihtuah a pawimawh a, chutiang chuan outcome tha ber a awm thei ang.
Titanium mesh cage hi ruh tissue nen a fuse theih nan eng chen nge a mamawh?
Fusion process hi thla engemaw zat a la ngai thei a, hei hi damlo kum, hriselna zawng zawng, leh a natna spinal segment lian leh te, a awmna hmun te a zirin a ni.
Titanium mesh cage hi damlo zawng zawng tan a tha em
Ni e, titanium mesh cage hi spinal fusion surgery nei tam tak tan chuan a tha thei hle. Mahse, damlo tinte mimal dinhmun chu uluk takin surgeon thiam takin a zirchiang a, enkawl dan tha ber tur a ni.
Titanium mesh cage hman hian eng hlauhawmna nge a neih?
Surgical procedure dang ang bawkin titanium mesh cage hman hian risk engemaw zat a keng tel a ni. Heng hlauhawmnate hi infection, implant failure, leh nerve chhiatna te a ni thei. Mahse, titanium mesh cage hman avanga hlauhawm zawng zawng hi a tlangpuiin a tlem a, implant hlawkna hian heng hlauhawmnate hi a tluk pha fo thin.
Titanium mesh cage hmanga spinal fusion surgery hnuah eng chen nge a dam leh theih?
Damlo pakhat zel leh operation tih nasat dan azirin dam leh hun chhung hi a inang lo thei. A tlangpuiin damlote chuan an hnathawh dan pangngaia an kir leh hmain kar engemaw zat chu an dam leh theih an beisei thei a ni. Dam lehna famkim chu thla engemaw zat atanga kum khat chhung a ngai thei.
Spinal fusion surgery hnuah titanium mesh cage hi lakchhuah theih a ni em?
A then phei chuan titanium mesh cage chu complication emaw implant failure emaw vangin lakchhuah a ngai thei bawk. Mahse, hei hi thil buaithlak tak a nih avangin revision surgery lama tawnhriat nei, surgeon thiam tak chauhin tih tur a ni. A tam zawkah chuan cage chu a hmunah a awm reng ang.
Thil siam chhuah te