Zawhna i nei em?        +86- 18112515727 ah      zawhfiah theih a ni  hla@orthopaedic-china.com ah hian a awm a
Please Choose Your Language
Hetah hian i awm: In » Thil siam chhuah te » Locking Plate a awm » Fragment lian tak a ni » Proximal Lateral Tibial Locking Plate-II

loading a ni

Share to:
facebook ah in share theih a ni
twitter hmanga share theih a ni
line sharing tih a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
whatsapp share theihna tur a ni
sharethih hi share theih a ni

A hnaih ber Lateral Tibial Locking Plate-II

  • 5100-26 thleng a ni

  • CZMEDITECH a ni

A awm theih dan:

Product Description chungchang

Proximal Lateral Tibial Locking Plate hi eng nge ni?

CZMEDITECH 3.5 mm LCP® Proximal Tibia Plate hi LCP Periarticular Plating System-a tel a ni a, hei hian locking screw technology leh plating technique pangngai a thlunzawm a ni. LCP Periarticular Plating System hian 3.5 mm LCP Condylar Plates hmangin distal femur-a complex fracture te, proximal femur-a complex fracture te chu 3.5 mm LCP Proximal Femur Plates leh 3.5 mm LCP hmangin a address thei a ni

Proximal Femur Hook Plates, leh 3.5 mm LCP Proximal Tibia Plates leh 3.5 mm LCP Medial Proximal Tibia Plates hman a nih chuan proximal tibia-a complex fracture a awm thin.


Locking compression plate (LCP) hian plate shaft-ah Combi hole a nei a, chu chuan dynamic compression unit (DCU) hole leh locking screw hole a thlunzawm a ni. Combi hole hian plate shaft sei zawng zawngah axial compression leh locking capability flexibility a pe a ni.

Plate-a thil awmte:

  • Anatomically contoured a ni a, proximal tibia lateral aspect hnaih ber a ni

  • Load-sharing construct siam turin tension theih a ni

  • Left leh right configuration-ah a awm a, 316L stainless steel emaw sumdawnna atana thianghlim (CP) titanium emaw a awm bawk

  • Plate shaft chhungah Combi hole 5、7、9 emaw 11 emaw neiin a awm

  • Lu atanga hla deuha round hole pahnih hian interfragmentary compression atan emaw, plate position secure turin 3.5 mm cortex screw leh 3.5 mm cancellous bone screw te an pawm a ni

  • Angled, threaded hole, round hole pahnih atanga hla takah chuan 3.5 mm cannulated locking screw chu a pawm a ni. Hole angle hian he locking screw hi plate head chhunga central locking screw nen inzawmkhawmin medial fragment a thlawp thei a ni

  • Combi holes, angled locking hole atanga hla takah chuan DCU hole leh threaded locking hole te chu an inzawm khawm a

  • Contact-a awm theihna profile


A hnaih ber Lateral Tibial Locking Plate a awm bawk

specification hrang hrang a awm

Thil siam chhuah te REF A sawifiahna Thickness a ni Vang Dung

A hnaih ber Lateral Tibial Locking Plate-II 

(3.5 Locking Screw/3.5 Cortical Screw hmang rawh)

5100-2601 ah zawh theih a ni 5 a awm L 4.2 12.5 97
5100-2602 ah zawh theih a ni 7 holes a awm L 4.2 12.5 124
5100-2603 ah zawh theih a ni 9 holes a awm L 4.2 12.5 151
5100-2604 ah zawh theih a ni 11 khur a ni L 4.2 12.5 178
5100-2605 ah zawh theih a ni 13 a awm L 4.2 12.5 205
5100-2606 ah zawh theih a ni 5 a awm R 4.2 12.5 97
5100-2607 ah zawh theih a ni 7 holes a awm R 4.2 12.5 124
5100-2608 ah zawh theih a ni 9 holes a awm R 4.2 12.5 151
5100-2609 ah zawh theih a ni 11 khur a ni R 4.2 12.5 178
5100-2610 ah zawh theih a ni 13 a awm R 4.2 12.5 205


Thlalak tak tak

3

Blog a ni

Proximal Lateral Tibial Locking Plate: Indication, Surgical Technique leh Outcome te thlirletna

Proximal tibia fracture hi enkawl harsa tak a ni thei a, a bik takin comminuted emaw osteoporotic fracture emaw a nih chuan. Heng complex fracture enkawlna atana hmanraw tangkai tak niin proximal lateral tibial locking plate (PLTLP) hman hi a lo chhuak ta a ni. He thuziak ah hian PLTLP hmanna nena inzawm indication, surgical technique leh outcome te kan sawi dawn a ni.

Indication te chu

PLTLP hi proximal tibia ruh tliak enkawlna atan hman a ni ber a, chutah chuan tibial plateau, medial leh lateral condyles, leh proximal shaft te pawh a tel a ni. A bik takin, hmanlai dan hmanga stabilize harsa, intramedullary nail emaw external fixators emaw hmanga fracture tan a tangkai hle. PLTLP hi proximal tibia nonunion emaw malunion emaw a awm chuan hman theih a ni bawk.

Surgery hman dan tur

PLTLP hi a tlangpuiin khup ruh (knee joint) lam hawia lateral approach hmanga dah a ni. Surgeon chuan khup lateral aspect chungah incision a siam ang a, chutah chuan fracture site chu a pholang ang. Chumi hnuah chuan fracture fragment te chu tihtlem a ni a, Kirschner wire hmangin a hmunah hun eng emaw chen an fix leh thin. A dawtah chuan PLTLP chu proximal tibia nena inmil turin contoured a ni a, locking screw hmangin a hmunah fixed a ni. Locking screw te hian ruh nena inzawmin stability a pe a, rotational emaw angular motion emaw a veng bawk.

A chhuahna tur

Zirna hrang hrangah PLTLP hman hian union rates sang tak leh clinical outcome tha tak a thlen tih hmuhchhuah a ni. Zirna pakhatah chuan thla 24 chhunga enkawl zui zelnaah union rate 98% leh mean Knee Society Score 82 a awm tih a tarlang. Zirna dang pakhatah chuan thla 48 chhunga enkawl zui zelnaah union rate 97% leh mean Knee Society Score 88 a awm tih a tarlang bawk. Mahse, hriat tur chu mimal outcome chu damlo leh fracture characteristic bik a zirin a danglam thei a ni.

Harsatna awm thei te

PLTLP hman avanga harsatna awm thei chu infection, nonunion, malunion, leh hardware failure te a ni. Damlo uluk taka thlan leh surgical technique hi harsatna awm thei tih tlem nan a pawimawh hle. Surgeon chuan a chhehvel soft tissue, peroneal nerve emaw lateral collateral ligament emaw tihchhiat loh nan a fimkhur tur a ni bawk.

Tawpna

Proximal lateral tibial locking plate hi proximal tibia-a complex fracture enkawlna atana hmanraw tangkai tak a ni. Stability a pe a, mobilization hmasa ber a siamsak a, hei hian clinical outcome tha zawk a thlen thei a ni. Harsatna a awm theih laiin, damlo uluk taka thlan leh surgical technique hian a hlauhawmna a ti tlem thei hle. A pum puiin PLTLP hi orthopedic surgeon-te armamentarium-a proximal tibia fracture enkawlna atana thil hlu tak a ni.

FAQs te

  1. Proximal lateral tibial locking plate hi proximal tibia fracture enkawlna kawng dang nen engtin nge a khaikhin? PLTLP hi proximal tibia-a complex fracture enkawlna atana hmanraw tangkai tak a ni tih hmuhchhuah a ni a, a bik takin traditional method hmanga stabilize harsa tak takte enkawlna atana hmanraw tangkai tak a ni. Mahse, mimal outcome chu damlo bik leh fracture characteristics a zirin a danglam thei.

  2. Proximal lateral tibial locking plate hman hian eng nge a thatna? PLTLP hian fracture fragment-te chu stable fixation a pe a, mobilization hmasa ber a siamsak a, hei hian clinical outcome tha zawk a thlen thei a ni. A bik takin complex fracture, traditional method hmanga stabilize harsa tak tan a tangkai hle.

  3. Proximal lateral tibial locking plate hman hian eng harsatna nge a thlen theih? PLTLP hman avanga harsatna awm thei te chu infection,nonunion, malunion, leh hardware failure te a ni. Damlo uluk taka thlan leh surgical technique hian harsatna awm thei tur a ti tlem thei hle.

  4. Proximal lateral tibial locking plate hi eng chen nge a dam theih? PLTLP dam hun chhung hi damlo pakhat zel leh a ruh tliak dan azirin a inang lo. Mahse, zirchianna hrang hrangah chuan PLTLP hmanna nen hian union rate sang tak a awm tih hmuhchhuah a ni.

  5. Fracture a dam hnuah proximal lateral tibial locking plate hi lakchhuah theih a ni em? Ni e, PLTLP hi a ruh tliak a dam hnuah lakchhuah theih a ni a, chu chuan harsatna emaw thil dang emaw a thlen a nih chuan. Mahse, hardware lakchhuah chungchanga thutlukna chu case-by-case basis-a siam tur a ni a, damlo surgeon nen inrawnkhawmin siam tur a ni.


Hma chiah: 
Dawtchiah: 

I CZMEDITECH Orthopaedic Expert te zawt rawh

Quality delivery-a harsatna awmte pumpelh turin kan pui che a, i orthopaedic mamawh chu a ngai pawimawh hle a, a hun takah leh budget-ah.
Changzhou-a Meditech Technology Co., Ltd. chuan a rawn ti a.

Thawhna

Tunah hian zawt rawh
© COPYRIGHT 2023 CHANGZHOU MEDITECH TECHNOLOGY CO., LTD., a hnuaia mi ang hian a hlawhtling hle. DIKNA ENGKIM A NI.