A tlem berah Interlink Plate a awm

A awm theih dan:

Product Description chungchang

CZMEDITECH Temporal Fossa Interlink Plate hi taksa peng hrang hranga hman theih tur solution a ni a, cranial defects siamthatna atan hman theih a ni.


  • Off-the-shelf, hman theih tura inpeih sterile implant te

  • Science lama zirchianna leh clinical data hmanga taksa peng hrang hrang (anatomic shapes)1

  • Bending & procedure hun tihtlem nan contoured a ni2

  • Economic solution a ni a, aesthetic result a awm bawk


Cranial defects siamthatna tur thlan chhuah kimchang.


  • Temporal (khawi lam/dinglam) 1.1.

  • Frontotemporal (khawi lam/dinglam) a ni.

  • Hma lam a ni

  • Universal


Anatomically Shaped a ni


Damlo 80 te clinical CT data zirchianna atanga chhut chuan mesh implants te contour bik hriat theih nan anatomical cranial features statistical mean siam a ni


Chumi hnuah CZMEDITECH CMF chuan cranial implant siam dan kan tawn dan aangin cranial defect awmna hmun tlangpui leh a lian leh te chu a hmuchhuak ta a ni.


Heng zirchianna result te hi inzawmkhawmin Temporal Fossa Interlink Plate anatomically-shaped, rigid implants siam a ni a, proprietary process hmangin bending leh kinking awm lovin smooth contour siam a ni.


Temporal Fossa Interlink Plate implants, i cranial reconstruction mamawhna atana cranial defect lian lo tak tak nena hman theih tura inpeih.

Features & Hlawkna te


Temporal Fossa Interlink Plate hi taksa peng hrang hranga awm, cranial defects siamthatna atana hman theih tur solution a ni.


  • Off-the-shelf, hman theih tura inpeih sterile implant te

  • Science lama zirchianna leh clinical data hmanga taksa peng hrang hrang (anatomic shapes) siam

  • Bending & procedure time tihtlem nan contoured a ni

  • Economic solution a ni a, aesthetic result a awm bawk

A sawifiahna

Hming REF Hrilhfiahna
Mastoid Interlink Plate (A thuk zawng:0.6mm) a ni. 3000-0127 thleng a ni Te
3000-0128 thleng a ni Hmanrua
3000-0129 thleng a ni Hrawl


Blog a ni

Maxillofacial Minimally Interlink Plate: Jaw Surgery-a hmanraw danglam tak a ni

Plate leh screw hman hi maxillofacial surgery-a thil pawimawh tak a ni ta a, a bik takin jaw ruh tliak leh deformity a awm chuan. A tlangpuiin heng plate te hi an lian hle a, an in fit theih nan hmun tam tak an mamawh a, mahse Maxillofacial Minimally Interlink Plate (MMI) a lo chhuah tak avangin jaw surgery hian inthlak danglamna nasa tak a tawk ta a ni. He thuziak ah hian MMI chungchang hrang hrang kan chhui dawn a, a structure, a thatna, a that lohna leh a clinical application te pawh kan zirchiang dawn a ni.

Inhmelhriattirna

Maxillofacial Minimally Interlink Plate (MMI) hi maxillofacial surgery lama thil thar tak a ni a, jaw fracture leh deformities kan enkawl danah pawh danglamna a thlen thei a ni. Traditional plate ang lo takin, a fit theihna tur hmun tam tak mamawh a ni a, MMI hi a compact leh install awlsam taka siam a ni. He device hi interlocking segment hrang hrang atanga siam a ni a, damlo tinte mamawh bik ang zela siam khawm leh siam danglam theih a ni.

MMI dinhmun (structure) a ni

MMI hi segment hrang hrang inzawmkhawm atanga siam a ni a, damlo tinte mamawh bik ang zela siamrem leh siam danglam theih a ni. Segment tin hi thil pawimawh pahnih atanga siam a ni a, chungte chu locking mechanism leh connecting rod te an ni. Locking mechanism hi ball te tak te a ni a, chu chu a kianga segment-a socket-ah a in fit a ni. Ball chu socket chhunga press a nih chuan segment pahnih inkarah hian inzawmna nghet tak, nghet tak a siam a ni. Connecting rod hian segment hrang hrangte inkarah bridge hna a thawk a, jaw fractured emaw deformed emaw chu stability leh support a pe a ni.

MMI thatna te

MMI hian traditional plate aiin advantage engemaw zat a nei a, chung zingah chuan:

  • Compact Design: MMI hi compact leh install awlsam taka siam a nih avangin an hmuiah hmun tlemte nei damlo tan chuan duhthlan tur tha tak a ni.

  • Customizable: MMI-a interlocking segment te hi damlo tinte mamawh bik ang zela siamrem leh siam danglam theih a ni a, hei hian enkawlna kawngah mimal zawkin a siam thei a ni.

  • Stable: MMI-a interlocking segment-te hian connection nghet, him tak a siam a, chu chuan jaw fractured emaw deformed emaw movement leh displacement a veng thei a ni.

  • Minimally Invasive: MMI hi minimally invasive technique hmanga install theih a ni a, hei hian damlo tan trauma a tlem zawk a, a dam rei zawk tihna a ni.

MMI that lohna te

MMI hian ṭhatna engemaw zat a neih laiin, a ṭhat lohna engemaw zat a nei bawk a, chungte chu:

  • Limited Range of Motion: MMI-a interlocking segment-te hian jaw range of motion a tihtlem thei a, hei hi damlo thenkhat tan chuan ngaihtuahawm tak a ni thei.

  • Removal harsatna: MMI-a interlocking segment te hi lakchhuah a harsa thei a, hei hi a hnua device lakchhuah a ngai a nih chuan ngaihtuahawm tak a ni thei.

MMI hi Clinical-a hman dan tur

MMI hi hmanraw tangkai tak a ni a, clinical application hrang hrangah hman theih a ni a, chung zingah chuan:

  • Jaw Fractures: MMI hmang hian jaw fractures enkawl theih a ni a, ruh tliak chu stability leh support a pe thei a ni.

  • Deformities: MMI hi jaw deformities, overbite emaw underbite emaw enkawlna atan pawh hman theih a ni.

  • Orthognathic Surgery: MMI hi orthognathic surgery nen hman dun theih a ni a, jaw deformities complex zawk siamthat nan hman theih a ni.

Tawpna

Maxillofacial Minimally Interlink Plate (MMI) hi maxillofacial surgery lama hmanraw thar revolutionary tak a ni a, jaw fracture leh deformities kan enkawl dan pawh a thlak danglam thei a ni. MMI hian traditional plate aiin advantage engemaw zat a nei a, chung zingah chuan design compact, customizability, stability, leh minimally invasive installation te pawh a tel. Mahse, he device hian chhiatna engemaw zat a nei bawk a, chu chu a kal theihna tur a tlem a, a lakchhuah harsat vang a ni. Heng harsatna awm thei te hi awm mahse, MMI hian clinical application hrang hrang a nei a, jaw fracture leh deformity hrang hrang enkawlna atan hman theih a ni.

FAQs te

  1. Engtin nge MMI hi maxillofacial surgery-a hman thin traditional plate nen a danglam?

  • MMI hi compact leh customizable tura siam a ni a, traditional plate erawh chu a tlangpuiin bulkier leh customizable lo zawk a ni thung.

  1. MMI install hi minimally invasive procedure a ni em?

  • Ni e, MMI installation hi minimally invasive technique hmangin tih theih a ni a, chu chuan damlo tan a dam rei zawk thei a ni.

  1. MMI hman chungchangah hian harsatna awm thei a awm em?

  • MMI hian thatna engemaw zat a neih laiin, a chhiatna tur pawh a awm a, chu chu range of motion limited leh removal harsat te hi a ni.

  1. MMI hi complex jaw deformities enkawlna atan hman theih a ni em?

  • Ni e, MMI hi orthognathic surgery nen hman dun theih a ni a, jaw deformities complex zawk siamthat nan hman theih a ni.

  1. MMI install nan hian eng chen nge hun a duh?

  • MMI dahna hi a tlangpuiin darkar tlemte chhungin tihfel theih a ni a, chu chu damlo tinte mamawh bik a zirin a ni.


Hma chiah: 
Dawtchiah: 

I CZMEDITECH Orthopaedic Expert te zawt rawh

Quality delivery-a harsatna awmte pumpelh turin kan pui che a, i orthopaedic mamawh chu a ngai pawimawh hle a, a hun takah leh budget-ah.
Changzhou-a Meditech Technology Co., Ltd. chuan a rawn ti a.

Thawhna

Tunah hian zawt rawh
© COPYRIGHT 2023 CHANGZHOU MEDITECH TECHNOLOGY CO., LTD., a hnuaia mi ang hian a hlawhtling hle. DIKNA ENGKIM A NI.