5100-31 thleng a ni
CZMEDITECH a ni
| A awm theih dan: | |
|---|---|
Product Description chungchang
CZMEDITECH atanga Distal Medial Tibial Locking Plate, hian locked plating thatna a pe a, chu chu system pakhata traditional plating hmanga flexibility leh hlawkna te a ni. Locking leh non-locking screw pahnih hmangin PERI-LOC System hian a ruala angular (eg varus/valgus) collapse do thei construct a pe a ni
fracture tihziaawmna atana puitu tha tak angin a thawk. Instrument set awlsam leh dik tak hian screwdriver pakhat, standardized drill bits, leh color-coded instrumentation a nei a, hei hian Distal Medial Tibial Locking Plate hi a ti awlsam a, hman a awlsam bawk.
Distal Medial Tibial Locking Plate Targeter hian locking screw option hmanga surgical approach invasive lo zawk a pe a ni. Plate-a screw hole configuration nena direct-a align-in Targeter hian screw dahna chu percutaneously-in a optimize a ni. CZMEDITECH implant zawng zawng hi a chakna leh a chhe thei lo tur atan quality sang ber 316L stainless steel hmanga siam a ni.
3.5mm Medial Distal Tibia Locking Plate precontour hian ruh chunglam nen a fit tha hle.
Screw hole tin hian screw hrang hrang pali zinga pakhat chu a pawm ang a, chu chuan fracture-a mimal mamawh dan azirin screw configuration chu i duh angin i siam thei ang:
• 3.5mm Locking Self-Tapping Cortex Screw hmanga siam a ni
• 3.5mm Self-Tapping Cortex Screw (Locking nei lo) hmanga siam a ni.
PERI-LOC Periarticular Locked Plating System hi puitling leh naupang damlo bakah ruh natna nei tan pawh hman theih a ni. Pelvic, ruh te tak te leh sei te, tibia, fibula, femur, pelvis, acetabulum, metacarpals, metatarsals, humerus, ulna, calcaneus leh clavicle te pawh fixation atan hman a ni.

| Thil siam chhuah te | REF | A sawifiahna | Thickness a ni | Vang | Dung |
A rilru a buai em em a, a rilru a hah em em bawk a. Distal Medial Tibial Locking Plate-II (3.5 Locking Screw/3.5 Cortical Screw hmang rawh) |
5100-3101 ah zawh theih a ni | 5 a awm L | 4.2 | 15.5 | 125 |
| 5100-3102 ah zawh theih a ni | 7 holes a awm L | 4.2 | 15.5 | 151 | |
| 5100-3103 ah zawh theih a ni | 9 holes a awm L | 4.2 | 15.5 | 177 | |
| 5100-3104 ah zawh theih a ni | 11 khur a ni L | 4.2 | 15.5 | 203 | |
| 5100-3105 ah zawh theih a ni | 5 a awm R | 4.2 | 15.5 | 125 | |
| 5100-3106 ah zawh theih a ni | 7 holes a awm R | 4.2 | 15.5 | 151 | |
| 5100-3107 ah zawh theih a ni | 9 holes a awm R | 4.2 | 15.5 | 177 | |
| 5100-3108 ah zawh theih a ni | 11 khur a ni R | 4.2 | 15.5 | 203 |
Thlalak tak tak

Blog a ni
Distal medial tibial locking plate hi surgical implant a ni a, distal tibia-a complex fracture enkawlna atan hman a ni. He plate hian ruh tliak chu stability leh support a pe a, chu chuan a dam tha thei a ni. He thuziak ah hian distal medial tibial locking plate nena inzawm features, benefits leh risks te kan sawi dawn a ni.
Distal medial tibial locking plate hi ruh lam enkawlna atana hman thin internal fixation device chi khat a ni. Tibia medial surface-a surgery hmanga dah theih tura siam a ni a, a locking screw-te chuan ruh-ah a nghet tlat a ni. Plate hi titanium emaw stainless steel emaw a siam a ni a, a profile a hniam a, chu chu ruh chung atang hian a chhuak nasa lo tihna a ni.
Distal medial tibial locking plate hian thil engemaw zat a nei a, chu chuan complex distal tibial fracture enkawlna atan duhthlanna tha tak a ni. Heng features te hi:
Distal medial tibial locking plate nena hman thin locking screw te hi stability leh fixation tha zawk pe thei tura siam a ni. Heng screw te hian plate chhungah an thread lut a, chu chu ruh chungah a lock a, solid fixation a siam a ni. Locking screw te pawh hi screw loose emaw back out emaw a awm theih nan an siam bawk.
Distal medial tibial locking plate hian profile hniam tak a nei a, chu chu ruh chung atang hian nasa takin a chhuak lo tihna a ni. He feature hian soft tissue irritation awm theihna a ti tlem a, dam rei theihna hun a siam bawk.
Distal medial tibial locking plate hian anatomic design a nei a, chu chu tibia medial surface pianzia nen a inmil hle. He feature hian fit tha zawk a pe a, plate stability a ti tha a, implant failure risk a ti tlem bawk.
Distal medial tibial locking plate hman hian hlawkna engemaw zat a nei a, chung zingah chuan:
Distal medial tibial locking plate hian enkawlna dang nena khaikhin chuan stability a ti tha zawk a ni. Hetianga stability tihpun hian ruh chu a dam tha thei a, complication awm theihna a ti tlem a, damlo result zawng zawng a ti tha bawk.
Distal medial tibial locking plate nena hman thin locking screw te hian solid fixation a siam a, implant failure hlauhawmna a ti tlem a ni. Hei hian operation tih nawn ngai a ti tlem a, damlo result pawh a ti tha hle.
Distal medial tibial locking plate anatomic design leh low profile hian damna hun a ti rang zawk a ni. Chumi awmzia chu damlote chu an hnathawh dan pangngaiah an kir leh thuai thei a, hrehawmna pawh a tlem zawk thei tihna a ni.
Distal medial tibial locking plate hian hlawkna tam tak a neih laiin, a hmannaah hian hlauhawmna a awm bawk. Heng hlauhawmnate hi:
Surgery dang ang bawkin distal medial tibial locking plate hman hian natna kai theihna a awm. He hlauhawmna tihziaawmna turin damlote chu operation hma leh operation hnuah antibiotics pek an ni ang.
Distal medial tibial locking plate hian implant failure risk a tihtlem laiin, a la thleng thei tho. Chutiang a nih chuan damlote chuan an harsatna siamhat nan operation dang an neih belh a ngai mai thei.
Surgery lai hian nerve leh thisen kalna kawng a chhiat theihna a awm. Hei hian a natna hmunah hian rilru hahna emaw, chak lohna emaw a thlen thei a, damdawi lam pan belh a ngai thei bawk.
Distal medial tibial locking plate hi distal tibia complex fracture te tan chuan enkawlna tha tak a ni. A locking screw te hian stability tha zawk a pe a, implant failure risk a ti tlem a, healing time pawh a ti rang zawk bawk. Mahse, surgery dang ang bawkin a hmannaah hian hlauhawmna a awm a ni. Complex distal tibial fracture i neih chuan i orthopedic surgeon nen inbia la, distal medial tibial locking plate hi i tan enkawlna tha ber a ni em tih en rawh.
Distal medial tibial locking plate hmanga operation atanga dam leh theih nan eng chen nge a ngaih?
Dam leh hun chhung hi a ruh tliak nasat dan leh damlo pakhat zel dam dan azirin a danglam thei. Mahse, damlo tam zawk chuan kar tlemte chhungin rit phurh hna an thawk tan thei a, thla engemaw zat chhungin an hnathawh dan pangngaiah an kir leh thei a ni.
Ka ruh tliak a dam hnuah plate chu lakchhuah ka ngai dawn em ni?
A tam zawkah chuan plate chu a hmunah a awm reng thei. Mahse, harsatna emaw thil dang emaw a thlen chuan lakchhuah a ngai mai thei.
Distal medial tibial locking plate implant tur hian eng chen nge surgery neih a ngai?
Surgery hi darkar 1-2 vel a ni tlangpui a, chu chu fracture complexity a zirin a ni.
Operation hnua taksa tihchakna khapna a awm em?
I orthopaedic surgeon chuan eng thiltih nge i pumpelh tur tih leh eng chen nge i tih loh tur tih chiang takin a hrilh ang che. A tlangpuiin, operation hnu thla engemaw zat chhung chu high-impact activities tih loh a pawimawh.
Distal medial tibial locking plate hi insurance hian a huam em?
Insurance plan tam zawk chuan distal medial tibial locking plate man hi an cover a, mahse coverage tih chian nan i provider hnenah zawhfiah a pawimawh.
Thil siam chhuah te