4200-07
CZMEDITECH
stainless steel medis
CE/ISO:9001/ISO13485
| kasedhiyan: | |
|---|---|
Video produk
Fitur & Keuntungan

Spesifikasi
|
NO.
|
REF
|
Katrangan
|
Qty.
|
|
1
|
4200-0701
|
Depth Gauge (0-120mm)
|
1
|
|
2
|
4200-0702
|
Kawat Pemandu Utas 2.5mm
|
1
|
|
3
|
4200-0703
|
Kawat Pemandu Utas 2.5mm
|
1
|
|
4
|
4200-0704
|
Mata Bor Cannulated karo Blok Terbatas 4.5mm
|
1
|
|
5
|
4200-0705
|
Cannulated Countersink Φ9
|
2
|
|
6
|
4200-0706
|
Kunci Hex Kab
|
2
|
|
7
|
4200-0707
|
Wrench kanggo Luwes Parallel Wire Guider
|
1
|
|
8
|
4200-0708
|
Multiple Wire Guider
|
1
|
|
9
|
4200-0709
|
Tutul Sekrup Cannulated 6.5mm
|
1
|
|
10
|
4200-0710
|
Obeng Heksagonal 3.5mm
|
1
|
|
11
|
4200-0711
|
Cleaning Stylet 2.5mm
|
1
|
|
12
|
4200-0712
|
Bor Lengan
|
1
|
|
13
|
4200-0713
|
Luwes Parallel Wire Guider
|
1
|
|
14
|
4200-0714
|
Obeng Cannulated Hexagonal 3.5mm
|
1
|
|
15
|
4200-0715
|
Kotak Aluminium Kab
|
1
|
|
16
|
4200-0516
|
Kunci DHS/DCS, Lengan Emas
|
1
|
|
17
|
4200-0517
|
Obeng Heksagonal 3.5mm
|
1
|
|
18
|
4200-0518
|
Pandhuan Sudut DCS 95 Derajat
|
1
|
|
19
|
4200-0519
|
DHS Angle Guier 135 derajat
|
1
|
|
20
|
4200-0520
|
DHS Reamer
|
1
|
|
21
|
4200-0521
|
DCS Reamer
|
1
|
|
22
|
4200-0522
|
Kotak Aluminium Kab
|
1
|
Gambar Nyata

Blog
Set instrumen sekrup cannulated 6.5mm minangka alat bedah sing digunakake ing operasi ortopedi kanggo nyetabilake patah tulang. Sekrup iki kothong lan dirancang kanggo ngidini kabel panuntun dilebokake ing balung sadurunge sekrup dipasang, saéngga nyuda karusakan jaringan alus nalika operasi. Ing artikel iki, kita bakal njelajah anatomi, aplikasi, lan teknik nggunakake set instrumen sekrup cannulated 6.5mm.
Set instrumen sekrup cannulated 6.5mm kasusun saka sekrup, kabel panuntun, bor cannulated, lan gagang. Sekrup digawe saka baja tahan karat lan diikat supaya bisa nyekel balung kanthi kenceng. Kabel panuntun digunakake kanggo nglebokake sekrup menyang balung lan diselehake dhisik, banjur sekrup. Bit pengeboran cannulated digunakake kanggo nggawe bolongan pilot kanggo kabel panuntun lan meneng, lan nangani digunakake kanggo ngapusi instruments sak surgery.
Set instrumen sekrup cannulated 6.5mm umume digunakake ing perawatan fraktur ing balung dawa, kayata femur lan tibia. Sekrup iki utamané migunani ing fraktur sing ora stabil lan mbutuhake fiksasi kanggo nyegah pamindahan. Desain cannulated sekrup ngidini karusakan jaringan alus sing paling tithik nalika dipasang, sing bisa mbantu ningkatake penyembuhan sing luwih cepet lan nyuda risiko komplikasi.
Saliyane kanggo nambani patah tulang, set instrumen sekrup cannulated 6.5mm uga bisa digunakake kanggo perawatan osteotomies (pemotongan balung bedhah) lan ing arthrodesis (fusi bedhah saka rong balung).
Sadurunge nggunakake set instrumen sekrup cannulated 6.5mm, penting kanggo ngira-ngira pasien lan cedera kasebut kanthi bener kanggo mesthekake yen fiksasi jinis iki cocog. Teknik bedhah kanggo nggunakake set instrumen sekrup cannulated 6.5mm kalebu langkah-langkah ing ngisor iki:
Siapke pasien kanggo operasi lan menehi anestesi.
Nggawe incision ing situs fraktur utawa osteotomy.
Gunakake teknik pencitraan kayata sinar-X utawa fluoroskopi kanggo nuntun nglebokake kabel panuntun menyang balung.
Gunakake bor cannulated kanggo nggawe bolongan pilot kanggo kabel panuntun lan meneng.
Lebokake kabel panuntun menyang balung lan verifikasi panggonane nggunakake teknik pencitraan.
Lebokake sekrup ing kabel pandhuan lan kenceng nganti aman.
Nutup incision lan aplikasi cast utawa piranti imobilisasi liyane yen perlu.
Wigati dimangerteni manawa panggunaan set instrumen sekrup cannulated 6.5mm mbutuhake latihan lan pengalaman sing tepat kanggo nyegah komplikasi kayata penempatan sekrup sing ora bener utawa karusakan ing jaringan sekitar.
Set instrumen sekrup cannulated 6.5mm duwe sawetara kaluwihan tinimbang jinis piranti fiksasi liyane. Iki kalebu:
Kerusakan jaringan alus minimal nalika dipasang
stabilitas dhuwur lan kekuatan fiksasi
Wektu penyembuhan sing luwih cepet amarga karusakan jaringan alus sing minimal
Resiko minimal saka komplikasi sing gegandhengan karo implan
Nanging, ana uga sawetara kekurangan kanggo nggunakake set instrumen sekrup cannulated 6.5mm, kalebu:
Potensi karusakan ing jaringan ing sakubenge nalika dipasang
Kesulitan karo panggonan sekrup ing wilayah anatomi tartamtu
Potensi gagal implan ing jinis fraktur tartamtu