4200-07
CZMEDITECH
stainless steel médis
CE/ISO:9001/ISO13485
| kasadiaan: | |
|---|---|
Video produk
Fitur & Kauntungan

Spésifikasi
|
NO.
|
REF
|
Katerangan
|
Qty.
|
|
1
|
4200-0701
|
Pengukur Jerona (0-120mm)
|
1
|
|
2
|
4200-0702
|
Threaded Guider Kawat 2.5mm
|
1
|
|
3
|
4200-0703
|
Threaded Guider Kawat 2.5mm
|
1
|
|
4
|
4200-0704
|
Cannulated Bor Bit kalawan Blok Limited 4.5mm
|
1
|
|
5
|
4200-0705
|
Cannulated Countersink Φ9
|
2
|
|
6
|
4200-0706
|
Konci Hex
|
2
|
|
7
|
4200-0707
|
Wrench pikeun adjustable Parallel Wire Guider
|
1
|
|
8
|
4200-0708
|
Sababaraha Wire Guider
|
1
|
|
9
|
4200-0709
|
Ketok Cannulated Screw 6.5mm
|
1
|
|
10
|
4200-0710
|
Obeng Heksagonal 3,5mm
|
1
|
|
11
|
4200-0711
|
Beberesih Stylet 2.5mm
|
1
|
|
12
|
4200-0712
|
Bor leungeun baju
|
1
|
|
13
|
4200-0713
|
Adjustable Parallel Kawat Guider
|
1
|
|
14
|
4200-0714
|
Obeng Cannulated héksagonal 3.5mm
|
1
|
|
15
|
4200-0715
|
Kotak Aluminium
|
1
|
|
16
|
4200-0516
|
DHS / DCS rengkuh, leungeun baju emas
|
1
|
|
17
|
4200-0517
|
Obeng Heksagonal 3,5mm
|
1
|
|
18
|
4200-0518
|
DCS Angle Guide 95 gelar
|
1
|
|
19
|
4200-0519
|
DHS Angle Guier 135 gelar
|
1
|
|
20
|
4200-0520
|
DHS Reamer
|
1
|
|
21
|
4200-0521
|
DCS Reamer
|
1
|
|
22
|
4200-0522
|
Kotak Aluminium
|
1
|
Gambar Saleresna

Blog
Set instrumen screw cannulated 6.5mm mangrupikeun alat bedah anu dianggo dina operasi ortopedi pikeun nyaimbangkeun patah tulang. screws ieu kerung sarta dirancang pikeun ngidinan pikeun kawat pituduh bisa diselapkeun kana tulang saméméh screw disimpen, sahingga ngaminimalkeun karuksakan jaringan lemes salila bedah. Dina tulisan ieu, urang bakal ngajalajah anatomi, aplikasi, sareng téknik ngagunakeun set instrumen screw cannulated 6.5mm.
Set instrumen screw cannulated 6.5mm diwangun ku screw, kawat pituduh, bor cannulated, sareng gagang. Screw dijieunna tina stainless steel sarta threaded pikeun ngidinan pikeun cekelan tulang pageuh. Kawat pituduh dipaké pikeun nyelapkeun screw kana tulang jeung ditempatkeun kahiji, dituturkeun ku screw nu. Bit bor cannulated dipaké pikeun nyieun liang pilot pikeun kawat pituduh na screw, sarta cecekelan dipaké pikeun ngamanipulasi instrumen salila bedah.
The 6.5mm cannulated screw instrumen set ilaharna dipaké dina pengobatan fractures dina tulang panjang, kayaning femur na tibia. screws ieu hususna kapaké dina fractures nu teu stabil sarta merlukeun fiksasi pikeun nyegah kapindahan. Desain cannulated tina screws ngamungkinkeun pikeun karuksakan jaringan lemes minimal salila sisipan, nu bisa mantuan pikeun ngamajukeun penyembuhan gancang sarta ngurangan résiko komplikasi.
Salian pikeun ngubaran patah tulang, set instrumen screw cannulated 6.5mm ogé tiasa dianggo dina pengobatan osteotomies (pemotong tulang bedah) sareng arthrodesis (fusi bedah dua tulang).
Sateuacan nganggo 6.5mm cannulated screw instrumen set, hal anu penting pikeun leres assess sabar jeung tatu maranéhanana pikeun mastikeun yén jenis ieu fiksasi téh luyu. Téhnik bedah pikeun ngagunakeun set instrumen screw cannulated 6.5mm ngalibatkeun léngkah-léngkah ieu:
Nyiapkeun pasien pikeun dioperasi sareng ngalaksanakeun anesthesia.
Jieun incision di situs narekahan atawa osteotomy.
Anggo téknik pencitraan sapertos sinar-X atanapi fluoroskopi pikeun nungtun nyelapkeun kawat pituduh kana tulang.
Paké bit bor cannulated pikeun nyieun liang pilot pikeun kawat pituduh na screw.
Selapkeun kawat pituduh kana tulang sareng pariksa panempatanna nganggo téknik pencitraan.
Selapkeun screw dina kawat pituduh jeung tighten eta nepika aman.
Tutup incision jeung nerapkeun matak atawa alat immobilization sejenna sakumaha diperlukeun.
Kadé dicatet yén pamakéan 6.5mm cannulated screw instrumen set merlukeun latihan ditangtoskeun jeung pangalaman pikeun nyegah komplikasi kayaning panempatan screw salah atawa ruksakna jaringan sabudeureun.
The 6.5mm cannulated screw instrumen set boga sababaraha kaunggulan leuwih tipe séjén alat fiksasi. Ieu kalebet:
Karusakan jaringan lemes minimal nalika dipasang
Stabilitas tinggi sareng kakuatan fiksasi
Waktu penyembuhan anu langkung gancang kusabab karusakan jaringan lemes minimal
Résiko minimal tina komplikasi anu aya hubunganana sareng susuk
Tapi, aya ogé sababaraha kalemahan pikeun ngagunakeun set instrumen screw cannulated 6.5mm, kalebet:
Poténsi ruksakna jaringan sakurilingna nalika dilebetkeun
Kasesahan jeung panempatan screw di wewengkon anatomis tangtu
Poténsi gagalna implan dina sababaraha jinis narekahan